C.2.4 Automatic Network Configuration

If the NIC and network resources are connected when an L-Server is created, the following settings matching the network resource definition will be registered automatically for the VM host that the L-Server will operate on.

In environments using the clustering function of VM management software, in order to enable the migration of VM guests and operation using the HA function, settings for LAN switch blades, virtual switches, and port groups are performed automatically for all VM hosts comprising the cluster.

When not configuring the tagged VLAN automatically for the uplink port of network resources, use the ROR console to configure the VLAN settings of uplink ports. Right-click the LAN switch in the server resource tree, and select [Modify]-[Network Settings] from the popup menu.

For details, refer to "5.4.4 Configuring VLANs on LAN Switch Blades" in the "User's Guide for Infrastructure Administrators (Resource Management) CE".

See

  • For details on the server NIC definitions, refer to "15.11 Server NIC Definition" in the "Reference Guide (Command/XML) CE".

  • For details on the nicdefctl command, refer to "5.15 rcxadm nicdefctl" in the "Reference Guide (Command/XML) CE".

  • For details on how to configure VLAN settings of LAN switch blade uplink ports, refer to "5.4.4 Configuring VLANs on LAN Switch Blades" in the "User's Guide for Infrastructure Administrators (Resource Management) CE".

Note

  • After creating an L-Server, if VM hosts are added to the cluster afterwards, Resource Orchestrator network settings are not performed automatically.
    Perform the same settings as the existing VM hosts in the cluster configuration for the LAN switch blades and virtual switches of the additional VM hosts.

  • For the gateway address, set the IP address of the existing node.


Default Blade Server Configuration to Support Automation of Network Configuration in Resource Orchestrator

Show the default blade server configuration to support automation of network configuration in Resource Orchestrator (server blade, specification of uplink port for network resource, correspondence relation of numbers of LAN switch blade and physical network adapter, etc.) in the following list. When there are no server NIC definitions, for network auto-configuration, the physical network adapter within the server blade is selected according to this list.

Table C.6 Default Blade Server Configuration for Network Auto-Configuration (for PRIMERGY BX900 S1/S2 Chassis)

Server Blade

Specification of Uplink Port
(Location of LAN Switch Blade)

LAN Switch Blade to Use

Physical Network Adapter Number (*6)

BX920 S1
BX920 S2
BX920 S3
BX922 S2
BX924 S3

CB1 and CB2, or no specification for uplink port

PY-SWB102(PG-SW111)
PY-SWB103(PG-SW112)

3,4

PY-SWB101(PG-SW201)
PY-SWB104(PG-SW109) (*1)
PY-CNB101 (*2)
PY-FEB101 (*3)

1,2

CB3 and CB4

PY-SWB101(PG-SW201)
PY-SWB102(PG-SW111)
PY-SWB103(PG-SW112)
PY-SWB104(PG-SW109)
PY-CNB101
PY-FEB101 (*3)

5,6

CB5 and CB6

PY-SWB104(PG-SW109)
PY-CNB101
PY-FEB101 (*3)

9,10

CB7 and CB8

PY-SWB102(PG-SW111)
PY-SWB103(PG-SW112)

11,12

PY-SWB101(PG-SW201)

9,10

BX924 S2

CB1 and CB2, or no specification for uplink port

PY-SWB101(PG-SW201)
PY-SWB102(PG-SW111)
PY-SWB103(PG-SW112)
PY-SWB104(PG-SW109)

1,2

CB3 and CB4

PY-SWB101(PG-SW201)
PY-SWB102(PG-SW111)
PY-SWB103(PG-SW112)
PY-SWB104(PG-SW109)
PY-CNB101
PY-FEB101 (*3)

3,4

CB5 and CB6

PY-SWB104(PG-SW109)
PY-CNB101
PY-FEB101 (*3)

7,8

CB7 and CB8

PY-SWB102(PG-SW111)
PY-SWB103(PG-SW112)

9,10

PY-SWB101(PG-SW201)

7,8

BX960 S1

CB1 and CB2, or no specification for uplink port

PY-SWB101(PG-SW201)
PY-SWB102(PG-SW111)
PY-SWB103(PG-SW112)
PY-SWB104(PG-SW109)

11,12

CB3 and CB4 (*4)

PY-SWB101(PG-SW201)
PY-SWB102(PG-SW111)
PY-SWB103(PG-SW112)
PY-SWB104(PG-SW109)
PY-CNB101
PY-FEB101 (*3)

3,4

CB5 and CB6 (*5)

PY-SWB104(PG-SW109)
PY-CNB101
PY-FEB101 (*3)

7,8

CB7 and CB8 (*5)

PY-SWB102(PG-SW111)
PY-SWB103(PG-SW112)

9,10

PY-SWB101(PG-SW201)

7,8

*1: When installing a PY-SWB104 (PG-SW109) on CB1 or CB2, set the transmission speed at the down link port of PY-SWB104 (PG-SW109) to 1 Gbps. For details on how to configure the settings, refer to the corresponding hardware manual.
*2: Only BX920 S3 and BX924 S3 are supported as server blades, when mounting PY-CNB101 on CB1 and CB2.
*3: Only BX920 S3 and BX924 S3 are supported as server blades, when using PY-FEB101.
*4: A LAN expansion card is mounted in expansion slot 1.
*5: A LAN expansion card is mounted in expansion slot 2.
*6: Use each physical network adapter, by performing redundancy using teaming.


Table C.7 Default Blade Server Configuration for Network Auto-Configuration (for PRIMERGY BX400 S1 Chassis)

Server Blade

Specification of Uplink Port
(Location of LAN Switch Blade)

LAN Switch Blade to Use

Physical Network Adapter Number (*5)

BX920 S2
BX920 S3
BX922 S2
BX924 S3

CB1 and CB2 (*1), or no specification for uplink port

PY-SWB102(PG-SW111)
PY-SWB103(PG-SW112)

3,7

PY-SWB101(PG-SW201)
PY-SWB104(PG-SW109) (*2)
PY-CNB101 (*3)
PY-FEB101 (*4)

2,6

CB3 and CB4

PY-SWB101(PG-SW201)
PY-SWB102(PG-SW111)
PY-SWB103(PG-SW112)
PY-SWB104(PG-SW109)
PY-CNB101
PY-FEB101 (*4)

9,10

BX924 S2

CB1 and CB2 (*1), or no specification for uplink port

PY-SWB101(PG-SW201)
PY-SWB102(PG-SW111)
PY-SWB103(PG-SW112)
PY-SWB104(PG-SW109)

2,4

CB3 and CB4

PY-SWB101(PG-SW201)
PY-SWB102(PG-SW111)
PY-SWB103(PG-SW112)
PY-SWB104(PG-SW109)
PY-CNB101
PY-FEB101 (*4)

7,8

*1: The same LAN switch blade model should be mounted in CB1 and CB2.
*2: When installing a PY-SWB104 (PG-SW109) on CB1 or CB2, set the transmission speed at the down link port of PY-SWB104 (PG-SW109) to 1 Gbps. For details on how to configure the settings, refer to the corresponding hardware manual.
*3: Only BX920 S3 and BX924 S3 are supported as server blades, when mounting PY-CNB101 on CB1 and CB2.
*4: Only BX920 S3 and BX924 S3 are supported as server blades, when using PY-FEB101.
*5: Use each physical network adapter, by performing redundancy using teaming.


Table C.8 Default Blade Server Configuration for Network Auto-Configuration (for PRIMERGY BX600 S3 Chassis)

Server Blade

Specification of Uplink Port
(Location of LAN Switch Blade)

LAN Switch Blade to Use

Physical Network Adapter Number (*)

BX600 series servers

NET1 and NET2, or no specification for uplink port

PG-SW107

3,4

NET3 and NET4

PG-SW104

7,8

* Note: Use each physical network adapter, by performing redundancy using teaming.


The numbers of physical network adapters given above can be checked in "Network Properties" on the [Resource Details] tab.

When the LAN switch blade is in IBP mode, the same physical network adapter as in the case of "no specification for uplink port" in the list above is selected.

When the user configures the network automatically using an arbitrary physical NIC, define the physical NIC to be used in the server NIC definition file, and specify the physical LAN segment in the server NIC definition from the network resource.

To reflect the physical NIC configuration specified in the server NIC definition file on Resource Orchestrator, use the rcxadm nicdefctl commit command. This enables automatic network configuration even in configurations using an arbitrary physical NIC.
However, when using server NIC definitions, the operation must be performed from the command-line.
In addition, when using rack mount and tower servers, automatic network configuration including the configuration using an arbitrary physical NIC is possible by defining the physical NIC to be used in the server NIC definition file and then specifying the physical LAN segment defined in the server NIC definition from the network resource.

See

  • For details on the server NIC definitions, refer to "15.11 Server NIC Definition" in the "Reference Guide (Command/XML) CE".

  • For details on the nicdefctl command, refer to "5.15 rcxadm nicdefctl" in the "Reference Guide (Command/XML) CE".

In the diagram, the default blade server configurations as described in the following configuration example when using a PRIMERGY BX900 S1 chassis are shown.

Table C.9 Configuration Example 1

Server blades

BX920 S2

Specification of uplink port

CB1 and CB2

LAN switch blade to use

PY-SWB103(PG-SW112)

Table C.10 Configuration Example 2

Server blades

BX920 S2

Specification of uplink port

Both "no specification for uplink port" and "CB3 and CB4" are specified

LAN switch blade to use

PY-SWB104(PG-SW109)

Figure C.1 Blade Server Diagram of Configuration Example 1


Figure C.2 Blade Server Diagram of Configuration Example 2