2.3 Device Polling

The Manager checks the statuses of registered devices by using SNMP, ping or unique protocol at intervals of 60 seconds (default). It is as follows which polling method.

Polling method

Protocol

Devices

Device status

SNMP

ETERNUS Disk storage system
NetApp FAS Series and V-Series

Communication status

SNMP

ETERNUS SN200 series Fibre Channel switch
PRIMERGY Fibre Channel switch blade
Brocade Fibre Channel switch
Brocade VDX series
PRIMERGY BX Ethernet Fabric Switch

unique protocol

server nodes for which Agent is installed

private protocol

VMware Infrastructure 3 Version 3.5 or later
VMware vSphere 4 or later
VMware ESXi 3.5 or later

ping

Devices supporting automatic detection, other than the above devices.
Manually embedded devices for which IP addresses are set.

With either SNMP or ping, Systemwalker Centric Manager linkage and Shell/bat linkage are enabled by default. The swsag code reported to Centric Manager is 4822. The linkage behavior can be modified. For information see "A.8 Device Polling Setting File".

Users can customize polling intervals, the time at which operation stops, the specification of devices to be excluded from polling operation, and other device polling functions. For details, see "A.8 Device Polling Setting File".

Note

When the device polling detects a change in network or device status, any event of "Device Polling Event" in the ETERNUS SF Event Guide is displayed. However, when the state change of device is detected by executing [Reload Conf.] operation, the following events are not displayed. Confirm the state from a Web Console.