The scope of the storage management functions of this software that can be used varies with the storage device model being used. For this software, the scope of available functions is represented as support levels, which are used as settings of the fault monitoring function and for other purposes. The table below lists the support levels that can be selected.
Support level | Typical device name | Device detection | Fault management | Management window linkage | Performance management | ||
---|---|---|---|---|---|---|---|
SNMP Trap monitoring | Device polling monitoring (*1) | Acquisition of device state | |||||
A | ETERNUS DX series | Automatic (*2) | Y1 | Y1 | Y1 | Y1 | Y1 |
B | Solaris OS, Windows, Linux, HP-UX, VMware, AIX server node on which ETERNUS SF Storage Cruiser's agent is already installed | Automatic (*2) | Y1 | Y1 | Y1 | Y1 | - |
C | VMware Infrastructure 3 Version 3.5 or later | Automatic (*2) | - | Y1 | Y1 | - | - |
D | NetApp FAS Series | Manual | Y1 | Y1 | - | Manual setting | Y1 (*7 For data collection only) |
E | ETERNUS LT20/LT20 S2 | Manual | Y1 | Y1 | - | Manual setting | - |
H | ETERNUS SN200 model 250M | Manual | Y1 | Y1 | - | Manual setting | - |
I | Other devices that are manually embedded | Manual | - (*3) | - (*4) | - | Manual setting | - |
Y1: Detail information on device internal elements can be displayed.
Y2: Information on the device and FC port can be displayed.
*1: The protocols using in the device polling are as follows.
Typical device name | Protocol Name |
---|---|
ETERNUS DX series | SNMP |
Server node on which ETERNUS SF Storage Cruiser's agent is already installed | unique protocol |
VMware Infrastructure 3 Version 3.5 or later | VMware dedicated protocol |
Other than listed above | ping |
*2: The "Detect device in subnet" function is not supported by the devices below. Specify and register the IP addresses.
The following devices that firmware version is V20L20 or later:
ETERNUS DX400 series, ETERNUS DX8000 series, ETERNUS4000 models 400 and 600, ETERNUS8000 models 800, 1200 and 2200
Solaris OS, Windows, Linux, HP-UX, VMware, AIX server node on which ETERNUS SF Storage Cruiser's agent is already installed
VMware server node
Solaris OS, Windows, Linux, HP-UX server node on which Softek Storage Cruiser's agent is already installed
ETERNUS LT250,LT270
The following switches may not be able to be detected in subnet depending on the firmware version, etc.
ETERNUS SN200 series, Brocade series, PRIMERGY BX600 Fibre Channel switch blade, Brocade VDX series, PRIMERGY BX Ethernet Fabric Switch
*3: For devices supporting SNMP Traps, this function is enabled by creating a SNMP Trap XML definition file.
*4: For devices supporting LAN, ping monitoring is enabled by specifying an IP address at manual embedding.
*5: SNMP Trap transmission must be set for each device. (This software does not automatically make said setting.)
*6: There are concerns in performance information. Refer to the Note in "7.1.1 Performance Information Types".
*7: For NetApp FAS Series. To refer to the performance information that is collected on the NetApp FAS Series, must be linkage with Systemwalker Service Quality Coordinator. Contact a Fujitsu system engineer for details on performance information.
*8: Only as for devices whose firmware version number is 3.0.1 or later, the performance management function is supported.