ETERNUS SF Express V15.3/ Storage Cruiser V15.3/ AdvancedCopy Manager V15.3 Installation and Setup Guide
ETERNUS

4.2.2 Configuring the network environment

If you set up firewalls between the Management Server and ETERNUS Disk storage system, set the following port numbers so as to allow transmissions to pass the firewalls.

Port number/Protocol

Communication start direction

Function

161/udp

From Management Server to ETERNUS Disk storage system

Configuration management, performance management, and polling

162/udp

From ETERNUS Disk storage system to Management Server

Fault management

1372/tcp (*1)

From Management Server to ETERNUS Disk storage system

Configuration management
(For ETERNUS DX80 S2/DX90 S2, ETERNUS DX400 S2 series, ETERNUS DX8000 S2 series)

Performance management
(For ETERNUS DX80 S2/DX90 S2, ETERNUS DX400 S2 series, ETERNUS DX8000 S2 series)

Advanced Copy
(For ETERNUS DX80 S2/DX90 S2)

50002/tcp

From Management Server to ETERNUS Disk storage system

Advanced Copy
(For ETERNUS DX80 S2/DX90 S2)

1999/tcp (*2)

From Management Server to ETERNUS Disk storage system

Configuration management

Advanced Copy
(For ETERNUS DX60/DX60 S2/DX80/DX90)

22/tcp

From Management Server to ETERNUS Disk storage system

Configuration management
(For ETERNUS DX80 S2/DX90 S2, ETERNUS DX400 S2 series, ETERNUS DX8000 S2 series)

Performance management
(For ETERNUS DX80 S2/DX90 S2, ETERNUS DX400 S2 series, ETERNUS DX8000 S2 series)

23/tcp

From Management Server to ETERNUS Disk storage system

Configuration management
(For ETERNUS DX60/DX60 S2/DX80/DX80 S2/DX90/DX90 S2, ETERNUS DX400 S2 series, ETERNUS DX8000 S2 series)

*1: For Maintenance-Secure connection
*2: For Maintenance connection

Express uses SNMP to register ETERNUS Disk storage system. Therefore, before registering devices, it is required to start SNMP Agent of ETERNUS Disk storage system. ETERNUS Disk storage system that has no SNMP Agent started cannot be registered.

Check the network environment, access privileges and settings of communication mode between Management Server and ETERNUS Disk storage system. If either communication mode of the Management Server or the ETERNUS Disk storage system is set to "Full (full duplex)", do not set the other to "Auto Negotiation".
Refer to the manual for each ETERNUS Disk storage system and check the network environment settings.

Point

The telnet connection and the Maintenance connection should be available on the ETERNUS Disk storage system.

Note

There are notes in combination with products using the SNMP trap reception function.
  • For Windows environment

    As with ServerView AlarmService, Express use OS standard SNMP trap reception service for fault management with SNMP Trap reception. Therefore, if any of the following products are mixed, take the same setting procedure as ServerView AlarmService is mixed.

    • Systemwalker Centric Manager

      Refer to each product's manual for specific setting method.

  • For Linux environment

    • As with ServerView AlarmService, Express use OS standard snmptrapd of net-snmp package for fault management with SNMP Trapreception.
      Therefore, if any of the following products are mixed, take the same setting procedure as ServerView AlarmService is mixed.

      • Systemwalker Centric Manager All versions

      • ServerView Resource Coordinator VE V2.1.1 - V2.1.3

      Refer to each product's manual for specific setting method.

    • When uninstalling the following product in an environment mixed with it, FJSVswstt package remains.

      • ServerView Resource Coordinator VE V2.1.1 - V2.1.3

      Execute the following command to delete FJSVswstt package:

      # rpm -e FJSVswstt