PRIMECLUSTER Global Link Services Configuration and AdministrationGuide 4.3Redundant Line Control Function

7.16 dspobserv Command

[Name]

dsphanet - Displaying the operation status of communication target monitoring

[Synopsis]

/opt/FJSVhanet/usr/sbin/dspobserv [-d]

[Feature description]

The dspobserv command displays the current operation status of communication target monitoring.

[Option]

You can specify the following option.


[-d]

An asterisk (*) is displayed at the end of a physical IP address of the active node that GLS recognizes as a communication target.

[Display format]

The following shows the display formats of monitoring status:

Display

Contents

observ status

ON

The monitoring function is enabled.

OFF

The monitoring function is disabled.

interval

In seconds the monitoring interval in the stationary status.

times

The monitoring count.

idle

Displays in seconds the wait time that elapses after monitoring starts and before the HUB links up.

repair_time

Displays the recovery monitoring interval in seconds.

fail over mode

YES

If the virtual interface is registered in the cluster resource, node switching is performed when all the transfer routes fail. (default)

NO

If the virtual interface is registered in the cluster resource, node switching is not performed when all the transfer routes fail.

VIP

Displays the name of a virtual interface held by the monitored node.

NIC

Displays the hostname or IP address of a real interface to be monitored.
When the -d option is specified, an asterisk (*) is displayed at the end of the physical IP address of the active node in a communication target.

Status

Active

Monitoring is in progress.

FAIL

Monitoring failed (recover monitoring in progress).

----

The monitoring function is disabled.

[Related commands]

hanetobserv

[Examples]

The following shows an example of displaying the status of communication target monitoring in GS linkage mode.

# /opt/FJSVhanet/usr/sbin/dspobserv