PRIMECLUSTER Wizard for NAS 4.3 Configuration and Administration Guide

Appendix B Turning of the control facility for the NAS-Cluster

In PRIMECLUSTER Wizard for NAS, it is monitored to the NAS-Cluster accessible by the ping / ping6 command. When the ping / ping6 command doesn't respond (It is not possible to access it), PRIMECLUSTER Wizard for NAS executes failover of the NAS-Cluster. In the following, it explains the method of the tuning of the parameter of Netapp resource.

Turning of the control facility for the NAS-Cluster

  1. The GLS resource monitors it between the cluster node and Switching-HUB. It should be set that failover of the NAS-Cluster doesn't execute it until the switching of the NIC of GLS is completed.
    In a word, it is necessary to meet the requirement of following.
    Monitoring Interval of GLS detector (a) + Switching time of the NIC with GLS (b) < Starting time of the NAS-Cluster failover (X)

    (a) + (b) = 10 (sec) + 30(sec) or 60(sec) < X (sec)

    Example

    * Switching time of the NIC with GLS

    case1

    not monitoring between HUB and HUB

    about 30 sec

    case2

    monitoring between HUB and HUB

    about 60 sec

    See

    Refer to "PRIMECLUSTER Global Link Services Installation and Administration Guide."

  2. After 300(recommended value) seconds pass, the RemoteFileSystems resource to monitor between the cluster node and the NAS device becomes faulted resource if the trouble is detected.
    Therefore, the value in which the failure detection time of NAS-Cluster and the failover time of NAS-Cluster are added should be within at 300 seconds.
    In a word, it becomes like the next expression.

    Starting time of the NAS-Cluster failover (X) <
    RemoteFileSystems failure time (300 sec) - time of the NAS-Cluster failover

    Therefore, it becomes the following.

    About 40sec. or about 70sec. < X < 300 sec - time of the NAS-Cluster failover (1)


The NAS cluster control facility will be initiated as follows:

As shown in the above figure, the time required for completing the NAS cluster control facility (1) is (m).

Turning of the Netapp resource setting for the ping / ping6 command

Default value is following:

A

Count of the ping / ping6 command for NAS-Cluster

10 count

B

Timeout time of the ping / ping6 command for NAS-Cluster

5 sec

C

Execution interval of the ping / ping6 command for NAS-Cluster

5 sec

The NAS-Cluster failover beginning time in default can be calculated from the following expression.

( B + C ) * ( A - 1 ) + B = (5+5) * 9 + 5 = 95 sec.

The NAS-Cluster failover beginning time in default is 95 sec.

Note

The required time for failover changes by the environment.