When you create redundant transfer routes on the network, you need to create a single type virtual interface from multiple interfaces by executing the following command on NAS;
vif create single virtual interface name interface 1, interface 2, ... |
The virtual interface name is specified as vif0, vif1, vif2, and so on.
Example
vif create single vif0 e0,e1 |
The virtual interface is created using the above command. If NAS is restarted, the virtual interface will be lost. You need to set up /etc/rc as the virtual interface can automatically be created during NAS restart using the following steps:
Mount /vol/vol0 on the NAS management server.
Add the "vif create single" command that is used to create a virtual interface above the ifconfig line. ifconfig sets up an actual interface in /etc/rc of NAS. Then, give commentary # to ifconfig and add the new ifconfig line for the virtual interface.
Example
vif create single vif0 e0,e1 |