This section explains messages starting from meter0000.
Get Status succeeded.
Description
Metering periodic log creation succeeded.
Corrective Action
No action is required.
Command succeeded.
Description
Deleting the metering log was successful.
Corrective Action
No action is required.
The config file is not found.
Description
The metering log deletion property file (metering_log.properties) cannot be found.
Corrective Action
Recreate the metering log deletion property file (metering_log.properties).
Refer to "8.7.3 Metering Log Settings" in the "Operation Guide CE" for information on the metering log operation config file.
The config file read failed.
Description
Reading the metering log deletion property file (metering_log.properties) was failure.
Corrective Action
Recreate the metering log deletion property file (metering_log.properties).
Refer to "8.7.3 Metering Log Settings" in the "Operation Guide CE" for information on the metering log operation config file.
Obtain imageName failed.
Description
L-Platform Management function has stopped.
Corrective Action
Check L-Platform Management function start and can be connected.
REST error occurred.
Description
L-Platform Management function has stopped.
Corrective Action
Check that there are no errors in the metering log operation config file (metering_log.properties).
Refer to "8.7.3 Metering Log Settings" in the "Operation Guide CE" for information on the metering log operation config file.
It failed in the acquisition of the value.
Description
The metering log operation config file (metering_log.properties) settings contain an error.
Corrective Action
Check that there are no errors in the metering log operation config file (metering_log.properties).
Refer to "8.7.3 Metering Log Settings" in the "Operation Guide CE" for information on the metering log operation config file.
DB error occurred.
Description
Writing in the metering database was failure.
Corrective Action
Check whether the metering database is running, and execute it again after it starts.
The start method is as follows.
[Windows Manager]
Display the service screen ([control panel] > [management tool] > [service]) by the user who has the manager authority. And start the [ServerView Resource Orchestrator Service Catalog Manager DB Service (Charging)] service.
[Linux Manager]
Execute the following command by super user authority.
/opt/FJSVctchg/bin/ctchgstart
In case not solving it by the above-mentioned, collect the command log and contact Fujitsu technical support.
It failed in the connection.
Description
Connecting to the metering database failed.
Corrective Action
Check whether the metering database is running, and execute it again after it starts.
The start method is as follows.
[Windows Manager]
Display the service screen ([control panel] > [management tool] > [service]) by the user who has the manager authority. And start the [ServerView Resource Orchestrator Service Catalog Manager DB Service(Charging)] service.
[Linux Manager]
Execute the following command by super user authority.
/opt/FJSVctchg/bin/ctchgstart
In case not solved by the above-mentioned action method, collect the command log and contact Fujitsu technical support.