Top
ETERNUS SF Express V15.1/ Storage Cruiser V15.1/ AdvancedCopy Manager V15.1 Messages
ETERNUS

A.5 Detail error messages of device information acquisition

This appendix explains in detail the error messages produced when the following events occur during acquisition or display of device information:

The messages explained in the appendix are logged to the following locations on the Managed Server.

Table A.2 Detail error messages on acquisition/reflection of device information

No.

Error message

Explanation

Action to be taken

1

[ERROR]NSP-API call exited abnormally. Volume=[Volume] Error=[STXerrno] Sense(SK SC SS)=[SK SC SS] message

Calling the hardware interface failed.

Depending on the output message, see "A.4 Detail error messages of ETERNUS Disk storage system" and take appropriate action based on the description of action to be taken.

2

[ERROR]The device information file is not consistent with the system devices. Try again with fetching all device information.

Device information file "device.ini" does not match system information.

[Windows version]
Execute acquisition/reflection of information on all devices.

3

[ERROR]Writing the inifile failed. Filename=[Filename] Section=[Section] Key=[Key] Value=[Value]

Writing the INI file failed.

[Windows version]
Check the status of the INI file.

4

[ERROR]Reading the inifile failed. Filename=[Filename] Section=[Section] Key=[Key]

Reading the INI file failed.

[Windows version]
Check the status of the INI file.

5

[ERROR]An API call exited abnormally. API=[API] Device=[Device] Error=[Errno] message

Calling the API failed.

[Solaris, Linux, HP-UX, and AIX versions]
Check the device status.

6

[ERROR]An API call exited abnormally. API=[API] Device=[Device] Volume=[Volume] Error=[Value of GetLastError] message

Calling the API failed.

[Windows version]
Check the device status.

7

[ERROR]A created process is exited abnormally. Command=[Command] ExitCode=[Code]

An internally executed command ended with an error.

Resolve the error, and re-execute the command if situation allows.

8

[ERROR]There is no result of the command. Command=[Command]

No results were output from the internally executed command.

9

Errors other than those above

A system error occurred.

Collect the information required for troubleshooting and contact a Fujitsu system engineer. (NOTE)

NOTE: Refer to the following manual for information on how to collect the information required for troubleshooting.
"Collecting maintenance information" in the "ETERNUS SF AdvancedCopy Manager Operation Guide"