This section explains the 672XX message series.
[Description]
Command execution was canceled. For details, refer to the event output at the same time.
[Corrective Action]
Refer to the event output at the same time.
[Description]
Deletion of the cloning image obj failed.
[Corrective Action]
Refer to the other messages output at the same time.
[Description]
The IP address or MAC address specified for obj cannot be used because it is already in use.
[Corrective Action]
Check and correct the option argument specified, and then perform the operation again.
When this message is output, the IP address or MAC address may already be being used for one of the following registered devices.
Chassis
LAN switches
Admin servers
Managed servers
Power monitoring devices
[Cloud Edition]
[Description]
The IP address or MAC address specified for obj cannot be used because it is already in use.
There may also be the following cases:
obj is already in use.
This also applies when an already excluded IP address (an admin server, a managed server, a network address, or a broadcast address) is specified for an exclusion IP address, when configuring a network resource.
The specified disk resource is used for an L-Server. The size and path cannot be changed for the disk resources used by an L-Server.
The specified disk resource is used by an L-Server. The disk resource has been registered in a resource pool. Therefore, disk registration cannot be released.
In obj, the MAC address written in "mac_address=" has already been used.
[Corrective Action]
Check and correct the option argument specified, and then perform the operation again.
When this message is output, the IP address or MAC address may already be being used for one of the following registered devices.
Chassis
LAN switches
Network device
Admin server
Managed server
Power monitoring device
For other cases, perform the following corrective actions.
When obj is already in use
Perform one of following corrective actions:
Review the specified option argument, and perform the operation again.
Exclude obj from an L-Server.
Release registration of obj from the storage pool.
In obj, when the MAC address written in "mac_address=" has already been used
Perform the operation again after correcting the specified MAC address.
[Description]
The command cannot be executed because another command is being executed by obj.
In the following cases, a resource name other than the one specified is displayed for obj.
When power operation of a chassis is performed while another process is being executed for a resource mounted in the chassis
When takeover of operations has been performed for a server which has been switched to a spare server and there is another physical OS or VM host that has the server configured as a spare server, and that physical OS or VM host is executing another process
[Corrective Action]
When obj is "Manager task"
Check the operating status of the admin server. After the operation being executed is complete, perform the operation again.
If this message is displayed while the admin server is stopped, operations being executed on the admin server may remain in the database. Start the admin server to complete the operations being executed on the admin server, or perform the operation again after restoring the collected configuration definition information.
When obj is something other than "Manager task"
Check the object obj and perform the operation again after the other command is complete.
However, when performing registration or deletion of managed servers or LAN switches in the same chassis, commands can only be performed for one resource at a time. This message will be displayed when commands are performed for multiple resources at the same time.
[Cloud Edition]
[Description]
The requested process cannot be performed as another process is already being performed.
[Corrective Action]
Take corrective action based on the content of obj.
When obj is a network resource
Wait for a short while and then repeat the operation. After deleting the L-Server connected to the network resource, perform the operation again.
When obj is "Manager task"
Check the operating status of the admin server. After the operation being executed is complete, perform the operation again.
If this message is displayed while the admin server is stopped, operations being executed on the admin server may remain in the database. Start the admin server to complete the operations being executed on the admin server, or perform the operation again after restoring the collected configuration definition information.
When obj is a LAN switch blade name
The network resource using the LAN switch blade which is displayed in obj exists. Delete the network resource and perform the operation again.
When obj is something other than the above
Wait for a short while and then repeat the operation.
[Description]
image has already been defined.
[Corrective Action]
Check and correct the object, then perform the operation again.
[Description]
The cloning image has not been specified.
[Corrective Action]
When this message is output during cloning image operation, collect the cloning image and then execute the command again.
[Virtual Edition]
[Description]
The system image of the managed server or the system image of the version specified does not exist.
[Corrective Action]
Check the system image of the relevant managed server.
If the specified version is incorrect, specify the correct version and execute the command again.
In some cases, the image file may not have been synchronized. Refer to "2.1 Starting and Stopping the Manager" in the "Operation Guide VE", and restart the manager service.
[Cloud Edition]
[Description]
The system image of the managed server or the system image of the version specified does not exist. Or there is no snapshot of the managed server, or the specified version of the snapshot was not found.
[Corrective Action]
Check whether there is a system image or snapshot of the relevant managed server.
If an incorrect version was specified, specify the correct version, and perform the operation again.
There is also a chance that image files have not been synchronized. Refer to "2.1 Starting and Stopping the Manager" in the "Operation Guide CE", and restart the manager service.
[Description]
The cloning image has already been deployed to the managed server server_name.
[Corrective Action]
Check and correct the relevant managed server, then perform the operation again.
[Description]
The specified servers include servers with different settings.
[Corrective Action]
Check the following settings for the target server.
Whether there are settings for HBA address rename
Whether there is server management software being used
Target servers with the same settings and perform the operation again.
For servers with different settings, process them individually.
[Virtual Edition]
[Description]
There is no spare server that matches the following conditions. Or the spare server specified does not meet the following conditions.
Power control is possible
The status is "normal", "warning", or "stop"
When the spare server is a VM host, it must meet all of the following conditions:
HBA address rename settings are configured, and an agent is registered
The status is "normal" or "warning"
A VM guest does not exist on a VM host (when the settings are not configured to switch to a spare server containing a VM guest)
[Xen]
It is not configured as the pool master (when the VM host is Citrix XenServer)
The server is not set as the switchover target for another switchover event
The server belongs to the same subnet as the operation server
[Corrective Action]
Choose one of the following corrective actions:
After checking there is a spare server that matches the above conditions, perform the operation again.
Specify a spare server that meets the above conditions, and then perform the operation again.
Specify a managed server that meets the above conditions as the spare server for use in server switchover, and then perform the operation again.
When setting a VM host as a spare server using the pre-configuration function, do so after importing HBA address rename settings and agent registration.
For details, refer to "12.2 Importing the System Configuration File" of the "User's Guide VE".
[Cloud Edition]
[Description]
When a physical L-Server has been switched over
There are no physical server resources available as spare servers in the specified spare server resource pool.
In other cases
There are no spare servers that fulfill the conditions. The specified spare server does not fulfill the following conditions.
Power control is possible
The status is "normal", "warning", or "stop"
When the spare server is a VM host, it must meet all of the following conditions:
HBA address rename settings are configured, and an agent is registered
The status is "normal" or "warning"
A VM guest does not exist on a VM host (when the settings are not configured to switch to a spare server containing a VM guest)
The server is not set as the switchover target for another switchover event
The server belongs to the same subnet as the operation server
[Corrective Action]
When a physical L-Server has been switched over
Register an additional physical server resource in the spare server resource pool specified for the target L-Server.
In other cases
Choose one of the following corrective actions:
Check that the physical server in the server pool which was specified as a spare server meets or exceeds all of the following conditions:
Number of CPUs
CPU Clock Speed
Memory Size
Number of NICs
Number of FCs in the FC connection pattern
There may be differences between the values in the definition files and the actual configuration information of that server.
Check that the correct values have been entered.
For details on the definition file, refer to "Chapter 8 Creating Definition Files" in the "Setup Guide CE".
A physical server cannot be found that has the number of FCs specified in the FC connection pattern.
Refer to "10.1.2 Storage Configuration" in the "Design Guide CE" for information on how to obtain the FC information for the physical server.
After checking there is a spare server that matches the above conditions, perform the operation again.
Specify a spare server that meets the above conditions, and then perform the operation again.
Specify a managed server that meets the above conditions as the spare server for use in server switchover, and then perform the operation again.
When setting a VM host as a spare server using the pre-configuration function, do so after importing HBA address rename settings and agent registration.
For details, refer to "10.2 Importing the System Configuration File" in the "User's Guide for Infrastructure Administrators (Resource Management) CE".
[Description]
obj has not been recovered.
Takeover of operations was executed on managed servers that have not performed Auto-recovery or manual switching.
[Corrective Action]
There is no need to take corrective action, as neither Auto-recovery nor manual switching to the managed server specified has been performed.
[Description]
The command cannot be executed because a public IP address has not been assigned.
[Corrective Action]
Check if installation of the software has been completed successfully.
For how to install software, refer to the following:
For Virtual Edition, refer to "Chapter 10 Configuring the Operating Environment of Managed Servers" of the "User's Guide VE".
For Virtual Edition, refer to "Chapter 10 Configuring the Operating Environment of Managed Servers" of the " User's Guide for Infrastructure Administrators (Resource Management) CE".
[Virtual Edition]
[Description]
The IP address specified is invalid.
[Corrective Action]
When this error occurs during the registration of a managed server
Check that the admin LAN IP address of the specified managed server is included in the subnet of the admin LAN, and then perform the operation again.
When this error occurs when changing the admin IP address of a managed server
Check the following and perform the operation again.
That the admin LAN IP address of the specified managed server is included in the subnet of the admin LAN
That IP addresses before and after changing are in the same subnets, when changing the admin IP addresses for a primary server or a spare server
When this error occurs when changing the admin LAN IP address of an admin server
Check that the IP address specified is the admin LAN IP address of the admin server, and then perform the operation again.
[Cloud Edition]
[Description]
One of the following is possible:
The IP address specified is invalid.
This message may be output when the rcxvmdiskagt command is executed.
[Corrective Action]
When this error occurs during the registration of a managed server
Check that the admin LAN IP address of the specified managed server is included in the subnet of the admin LAN, and then perform the operation again.
When this error occurs when changing the admin IP address of a managed server
Check the following and perform the operation again.
That the admin LAN IP address of the specified managed server is included in the subnet of the admin LAN
That IP addresses before and after changing are in the same subnets, when changing the admin IP addresses for a primary server or a spare server
When this error occurs when changing the admin LAN IP address of an admin server
Check that the IP address specified is the admin LAN IP address of the admin server, and then perform the operation again.
When this message is displayed when the rcxvmdiskagt command was executed
Ensure that the specified IP address is the IP address of admin LAN for the VM host, then perform the operation again.
[Description]
The range of IP addresses defined on the admin server is already in use.
[Corrective Action]
Check the range of the IP addresses (DHCP range) defined on the admin server.
[Description]
An error has occurred on the admin server.
[Corrective Action]
Check the following:
If setup of the admin server was completed successfully.
For setup, refer to "2.1 Manager Installation" of the "Setup Guide VE" or "Setup Guide CE".
Whether communication with the server management unit is possible
Use the ping command or another method to check if there is a problem with the network environment between the admin server and the server management unit.
If a cable is disconnected from the LAN connector, connect it.
Whether Write (reference and updating) authority is possessed for the SNMP setting of the management blade
Check the SNMP community name set from the ROR console.
If it was omitted, [public] will be specified.
Check that the management blade of the managed server has Write (reference and updating) authority for the SNMP community name specified.
If the SNMP community name does not have Write (reference and updating) authority, change the authority settings.
Check that the values of the IP address, user name, and password set for the Remote Management Controller when registering the managed server have not been changed from their original values.
For details of checks and the setup method, refer to the manual of the server being used.
Refer to "2.1 Starting and Stopping the Manager" of the "Operation Guide VE" or "Operation Guide CE", and check whether the "Related services" have been started on the admin server. If they have stopped, restart them.
For how to check and start services, refer to "2.1 Starting and Stopping the Manager" of the "Operation Guide VE" or "Operation Guide CE".
After starting any stopped services, perform the operation that resulted in the error again.
If this does not resolve the problem, collect troubleshooting information and contact Fujitsu technical staff.
[Description]
Acquisition of managed server information failed because the server cannot communicate with the managed server or server management unit.
[Corrective Action]
Check the status of the managed server and the server management unit, the value specified for the operand, and the values set for the following:
That the IP address of the server management unit of the managed server is set correctly and the server is operating normally
The SNMP community settings of server management unit for the managed server
That the SNMP community name specified from the ROR console has Read (reference authority) or Write (reference and updating) authority.
The SNMP community settings of the managed server
That the SNMP community name of the managed server has Read (reference authority).
Specify the same SNMP community name for the managed server and the server management unit.
That the values of the IP address, user name, and password set for the Remote Management Controller when registering the managed server have not been changed from their original values
That the IP address of the managed server specified is correct
Setup of the agent for the specified managed servers was completed successfully
Network settings (such as DNS) of the admin server are correct and the execution of OS network-related commands is completed within seconds
When this message is displayed, take the following corrective actions, depending on the case:
When this message is displayed after reconfiguration of hardware properties following replacement, and there are no problems with the managed server or server management unit
There is a possibility that the reconfigured hardware properties were temporarily unobtainable.
Reconfigure the hardware properties again.
When this message is displayed during deployment of a cloning image
Registration of agents after deployment has failed. Either redeploy the cloning image or refer to step 2. in the corrective action of "Message number 67328" and recover the managed server the image was deployed to.
When a single cloning image was being deployed to multiple managed servers, take corrective action for all of the managed servers.
When a managed server is VMwareESXi
Necessary information cannot be obtained from the required software.
Refer to ServerView Operations Manager in "2.4.2.2 Required Software" in the "Design Guide VE", and enable management of the target server using ServerView Operations Manager.
When a managed server is VMwareESXi and another vendor's server
The definition file may not exist or the target managed server may not have been defined in the definition file.
Confirm that there is no error in the filename or content of the definition file, referring to "C.1.5 Configuration when Creating a Virtual L-Server Using VMware ESXi on Other Vendor's Servers " in the "Setup Guide CE".
If this does not resolve the problem, collect troubleshooting information and contact Fujitsu technical staff.
[Description]
An error has occurred during power control of a managed server.
[Corrective Action]
Check the following and take corrective action.
The SNMP community name set from the ROR console
If it was omitted, [public] will be specified.
Whether or not the management blade of the managed server has Write (reference and updating) authority for the SNMP community name specified
If the SNMP community name does not have Write (reference and updating) authority, change the authority settings.
That the values of the IP address, user name, and password set for the Remote Management Controller when registering the managed server have not been changed from their original values
For details of checks and the setup method, refer to the manual of the server being used.
[Description]
The chassis has not been registered.
The admin LAN of the chassis including the server to be registered may not have been set correctly.
[Corrective Action]
After registering a chassis, perform the operation again.
When the chassis has been registered, check the admin LAN settings of the server to be registered.
[Description]
The managed server specified does not meet the requirements for Auto-recovery or manual switching.
The name of the managed server specified is displayed for obj.
The following detailed causes are displayed for detail.
no image
Backup of the system image of the server specified was not performed.
[Corrective Action]
Take corrective action based on the detailed cause.
no image
After system images are backed up on the server specified, perform manual switching again.
[Description]
A Resource Orchestrator agent has not been installed on a managed server.
The name of the managed server is displayed for obj.
[Corrective Action]
After installing a Resource Orchestrator agent on the managed server, execute the command again.
[Description]
An error has occurred in LAN switch control.
The network management command is displayed for command.
A character string indicating the process that resulted in an error during network management is displayed for rcxerrno.
One of the following is displayed for mip:
The admin IP addresses of the managed LAN switch
Admin IP addresses or server names of managed servers
An error may occur during the following conditions:
When specifying a different IP address with LAN switch
When specifying a SNMP community name not set in the LAN switch
When the LAN switch is not operating correctly
When the LAN switch is replaced with a different type of LAN switch from the original, and restoration performed
[Corrective Action]
After checking the following, execute the command again.
That the LAN switch is a supported model
That the LAN switch is the same model as the original
Whether the content of the following settings of LAN switch matches that of Resource Orchestrator
If they are different, correct the settings of both LAN switch and Resource Orchestrator so they match.
The admin IP addresses of LAN switch
The subnet mask for the admin IP addresses of the LAN switch
VLAN ID to which the admin IP addresses of the LAN switch belong
The connection port for the admin IP addresses of the LAN switch
SNMP community name
The user name for remote login
The password for remote login
The privileged password for remote login
Whether there is an abnormality in the communication route between the admin LAN and the LAN switch
Check whether a LAN cable is unplugged or the LAN switch is powered off.
Whether the LAN switch is operating correctly
Check the following, and if necessary, remove the problem using the maintenance procedure of the LAN switch.
The LAN switch is powered on
The SNMP agent is operating normally
The server can connect to the LAN switch using telnet
Information
When telnet connection is disabled, enable it.
For details on settings, refer to the manual for the server.
The number of simultaneous connections using telnet may be limited depending on the model. In this case, log out of other telnet connections.
[Description]
An internal command for obtaining server information may be being executed in another process.
[Corrective Action]
Wait a couple of minutes and then execute the command again.
[Description]
Command execution failed on the managed server.
The admin IP address of the managed server or the server name is displayed for mip.
[Corrective Action]
Check the following on the managed server indicated for mip.
Check that the managed server is not down
If the system is down, start the system from the appropriate OS.
Check that the managed server was started using the appropriate OS
If it was not, change the BIOS settings referring to the manual for the server.
[Linux]
Check if the LAN card is correctly configured and activated on the system by executing the /sbin/ifconfig -a command
If it has not been configured and activated correctly, configure the LAN card referring to the Linux installation guide.
If the problem is still not resolved after performing the above actions, collect the corresponding message and troubleshooting data, and contact Fujitsu technical staff.
[Description]
An error has occurred in VLAN settings for LAN switch.
[Corrective Action]
For the LAN switch of the managed server that was the target of the operation (such as server registration or server deletion) that resulted in the error, confirm the following.
The LAN switch is powered on
The SNMP agent is operating normally
The server can connect to the LAN switch using telnet
Information
When telnet connection is disabled, enable it.
For details on settings, refer to the manual for the server.
The number of simultaneous connections using telnet may be limited depending on the model. In this case, log out of other telnet connections.
If the end host mode is being used, the VLAN ID of the active external port that is also the Selected Port cannot be deleted.
Deactivate that port or change the VLAN IDs of all the internal ports that have the same VLAN IDs as the external port and the retry.
External ports that are Selected Ports can be checked by logging into the LAN switch and running the show pin-interface all command.
After checking the above, if necessary, remove the problem using the maintenance procedure of the LAN switch.
For Virtual Edition, refer to "Replacing LAN switch blades" in "6.3.4 Replacing Non-server Hardware" of the "Operation Guide VE" and reflect the VLAN information on the server, then perform the operation again.
For Cloud Edition, refer to "Replacing LAN switch blades" in "9.3.4 Replacing Non-server Hardware" of the "Operation Guide CE" and reflect the VLAN information on the server, then perform the operation again.
[Description]
PRIMECLUSTER GLS has not been installed on the managed server.
[Corrective Action]
Install PRIMECLUSTER GLS on the managed server.
Refer to the product manual for the installation method of PRIMECLUSTER GLS.
[Description]
The command terminated abnormally.
[Corrective Action]
Perform the operation again.
[Description]
Password decryption failed.
[Corrective Action]
If this message is displayed when importing a system configuration file, check that the password for the resource definition specified as "encrypted" (an encrypted password) has been configured as an encrypted character string.
For the system configuration file, refer to "Appendix B Format of CSV System Configuration Files" in the "User's Guide VE".
If the problem is still not resolved after performing the above actions, collect the corresponding message and troubleshooting data, and contact Fujitsu technical staff.
[Cloud Edition]
[Description]
Password decryption failed.
[Corrective Action]
When the message above is output during reading of a configuration definition file
Confirm if the password is configured using an encrypted character string in the resource definition line for specifying "encrypted" (encrypted password).
For details on configuration definition files, refer to "Appendix B Format of CSV System Configuration Files" in the "User's Guide for Infrastructure Administrators (Resource Management) CE".
When message is output while network configuration information file is being read and "true" is set for PasswordEncryption tag or when rcxnetworkservice command is executed.
Check if an encrypted character string is configured for the Password element or the PrivilegedPassword element.
Refer to "13.6.1 Creating" in the "Reference Guide (Command/XML) CE" for information about network configuration information.
If the problem is still not resolved after performing the above actions, collect the corresponding message and troubleshooting data, and contact Fujitsu technical staff.
[Description]
The range of IP addresses specified is incorrect.
One of the following is displayed for code:
9:
An invalid IP address is included in the specified range of IP addresses
10:
The range of the start IP address and that of the end IP address are incorrect
13:
The start IP address and end IP address are not in the same subnet
14:
The start IP address is the same as the subnet number
15:
The end IP address is the same as the broadcast address
102:
The host of the start IP address specified for the redundancy method is not the same
103:
The same subnet of the start IP address specified for the redundancy method has been used
201:
IP addresses of registered managed servers exist outside the range of specified admin IP addresses, or a different subnet was specified when registered managed servers already exist
[Corrective Action]
Take corrective action based on the content of code.
For "201"
Choose one of the following corrective actions:
Specify a range of addresses including the registered managed server addresses in the same subnet as the range of admin IP addresses prior to change, and then perform the operation again.
Release the IP addresses of the registered managed servers, and then perform the operation again.
For a code other than the above
Check the parameter, and then perform the operation again.
[Virtual Edition]
[Description]
The option specified for option is not supported.
[Corrective Action]
Check and correct the option specified, and then perform the operation again.
[Cloud Edition]
[Description]
When a physical L-Server was created, "NICs.NIC.NetworkLinkfor NICIndex(num)" is displayed in option
Network resources cannot be specified for the displayed NIC.
The number displayed for NICIndex(num) is a value one lower than the number specified when creating the L-Server.
When "-system" or "-force" is displayed in option
The storage unit to which the disk resource, for which an operation was attempted using the rcxadm lserver attach command or the rcxadm lserver detach command, belongs does not support the -system option or the -force option of the rcxadm lserver command used for the switchover of operating and standby storage. Therefore, the -system option and the -force option cannot be specified.
When "resource" is displayed in "option"
The error may be the result of one of the following:
The specified resource is not the target of the movement
The resource has not been registered in the orchestration tree
When "-deny deldisk" is displayed in option
-deny deldisk (do not delete) cannot be specified when reducing disks that have been separated from the virtual storage from the specified L-Server.
In other cases
The option specified for option is not supported.
[Corrective Action]
When a physical L-Server was created, "NICs.NIC.NetworkLinkfor NICIndex(num)" is displayed in option
Change the network resource settings and perform the operation again.
When "-system" or "-force" is displayed in option
Check that switchover of operating or standby storage is being performed for the correct storage unit, or check the content of the replication definition file.
When "resource" is displayed in "option"
Specify a movable resource. Also, register resources that have not been registered in the resource orchestration tree into resource pools.
When "-deny deldisk" is displayed in option
This disk is deleted when reducing disks that have been separated from the virtual storage from the specified L-Server. To reduce, specify the -allow deldisk option and retry.
The -deny deldisk option can only be specified when detaching disks from physical L-Servers or virtual L-Servers with the VM type Hyper-V.
In other cases
Check and correct the option specified, and then perform the operation again.
[Description]
Deletion of the oldest cloning image failed because it is in use.
[Corrective Action]
Delete one or more versions of cloning images that are not in use, then perform the operation again.
[Description]
Deleting the version version of the cloning image failed because it is in use.
[Corrective Action]
Enable use of the specified version version of the cloning image, and then perform the operation again.
[Virtual Edition]
[Description]
An error has occurred during the process set in "17.6 Network Parameter Auto-Configuration for Cloning Images" of the "User's Guide VE".
A number corresponding to one of the following processes is displayed for type:
10: PRE_TGTSVR_IMAGE_CREATE
The process before collection of cloning images
11: POST_TGTSVR_IMAGE_CREATE
The process after collection of cloning images
13: POST_TGTSVR_IMAGE_INSTALL
The process after deployment of cloning images
[Corrective Action]
Take the corrective action for "Message number 61501" or "Message number 61502" displayed in the event log.
When neither "Message number 61501" nor "Message number 61502" are displayed, collect troubleshooting information and contact Fujitsu technical staff.
[Description]
Login failed.
[Corrective Action]
Enter the correct user ID and password, and then log in again.
When there is no error in the user ID and password, and the management account is a new addition, there is an error in the password configured during account creation.
For Virtual Edition, Set the password given in "Chapter 5 Managing User Accounts" of the "Operation Guide VE" again.
For Cloud Edition, Set the password given in "Chapter 3 Managing User Accounts for Infrastructure Administrators" of the "Operation Guide CE" again.
[Description]
Writing to the file or directory specified for filename failed because the file type is invalid.
[Corrective Action]
After performing one of the following corrective actions perform the operation again.
Change the name of the file or directory displayed for filename
Move or delete the file or directory displayed for filename
[Description]
The environment variable variable is invalid.
[Corrective Action]
Check the value of the variable variable and then perform the operation again.
[Description]
The shell to be started was not found.
[Corrective Action]
Correct the environment variable SHELL.
[Description]
Execution of the command described in obj failed.
[Corrective Action]
Check the following, resolve the problem, and execute the command again.
The command execution environment is correct
Execute the /opt/FJSVrcvhb/bin/rcxhbactl command from a desktop environment.
Users have sufficient command execution authority
There is enough free memory
[Description]
The file or directory specified for filename was not found.
[Corrective Action]
Specify an existing file or directory.
[Cloud Edition]
[Description]
The file or directory specified for filename was not found.
[Corrective Action]
Specify an existing file or directory.
[Description]
The file or directory specified for filename cannot be created.
[Corrective Action]
Check the access authority for the directory.
[Description]
There is no home directory for the executing user.
[Corrective Action]
For the OS user account on which the command has been executed, check if the following has been set and the directory set is on the admin server. Correct them and perform the operation again.
There is an entry of the user account on which the command has been executed on "Local Users and Groups" of the admin server
In the environment valuable of the above account, APPDATA or USERPROFILE exists and the correct directory is set
[Description]
The chassis chassis_name was not found.
[Corrective Action]
Check the name of chassis specified.
[Description]
The specified alias(alias) was not found.
[Corrective Action]
Execute the following command and check the alias, and then perform the operation again.
[Windows Manager]
>rcxadm certctl list <RETURN> |
[Linux Manager]
# rcxadm certctl list <RETURN> |
Example
In the following, client2, client1, server5, server4, server3, server2, and server1 are aliases.
Truststore: |
[Description]
The keystore file was not found.
[Corrective Action]
Check that the keystore file exists in the following directory.
When operating managers in clusters, check that the shared disk for managers is mounted, and then perform the operation again.
If it does not exist, collect troubleshooting information and contact Fujitsu technical staff.
When it is a manager
[Windows Manager]
Installation_folder\SVROR\Manager\etc\opt\FJSVssmgr\current\certificate\common_truststore
[Linux Manager]
/etc/opt/FJSVrcvmr/opt/FJSVssmgr/current/certificate/common_truststore
When it is an agent
[Windows] [Hyper-V]
Installation_folder\Agent\StorageRM\Agent\etc\certificate\agent_truststore
[Linux] [VMware] [Xen] [KVM]
/etc/opt/FJSVssagt/certificate/agent_truststore
[Solaris]
/etc/opt/FJSVrcvat/certificate/agent_truststore
[Description]
The keystore file may be damaged or the file is incorrect.
[Corrective Action]
Collect troubleshooting information and contact Fujitsu technical staff.
[Description]
An internal error occurred.
[Corrective Action]
Collect troubleshooting information and contact Fujitsu technical staff.
[Description]
The command syntax is incorrect. "usage" is displayed.
[Corrective Action]
Check and correct the command format, and then perform the operation again.
[Virtual Edition]
[Description]
The object obj does not support function.
The name of the unsupported function is displayed for function.
When function cannot be used for obj, detail will not be displayed.
When function cannot be used because of usage conditions, the following detailed information will be displayed enclosed in parentheses for detail.
"Out of DHCP range"
The IP address displayed in obj is out of the range of IP addresses for which the backup and restore functions for system images can be used.
"invalid switchover method"
Server switchover using backup and restore cannot be used for the server displayed for obj.
This is displayed when a VM host is operating on the server displayed for obj.
"invalid model"
The target of operation displayed for obj is a model that does not support function.
"invalid destination"
The VM guest displayed for obj does not support movement to the VM host specified as the destination.
"VM type"
The target of operation displayed for obj is server virtualization software that does not support function.
[Xen]
Setting and release of VM maintenance mode for Citrix XenServer pool masters is not supported.
"OS type"
The target of operation displayed for obj is a server OS that does not support function.
"incompatible network devices"
The NIC configuration of the target of operation displayed for obj does not match the conditions for spare servers of function.
"incompatible IBP group configuration between switch-1 and switch-2"
The IBP group settings of the switch switch-1 of the switchover source, and the switch switch-2 of the switchover target that is displayed for obj do not match the operation conditions of function.
"incompatible mode between switches switch-1 (mode-1) and switch-2 (mode-2)"
The modes of the switch switch-1 of the switchover source, and the switch switch-2 of the switchover target that is displayed for obj do not match.
The modes of each switch, "IBP mode", "switch mode", or "end-host mode" is displayed for mode-1 and mode-2.
"VIOM"
As the server displayed for obj already has VIOM coordination configured as its virtualization method, HBA address rename cannot be set.
"invalid deployment configuration"
The function displayed for function is one not supported in the current environment. For details of backup and restore, and cloning, use ServerView Deployment Manager. For Virtual I/O (HBA address rename), please use ServerView Virtual-IO Manager.
When this message is displayed for other operations, it is not necessary to perform those operations.
For "difference of NIC setting for Admin LAN"
When the settings of the NIC for the admin LAN are a server different to that displayed for obj, configuration of a spare server is not possible.
"Manager is Linux"
This cannot be used with a Linux manager.
[Corrective Action]
This message is displayed because use of an unsupported function was attempted for obj. No action is required.
[Cloud Edition]
[Description]
The object obj does not support function.
The name of the unsupported function is displayed for function.
When function cannot be used for obj, detail will not be displayed.
When function cannot be used because of usage conditions, the following detailed information will be displayed enclosed in parentheses for detail.
In detail, the following detailed information is displayed:
"power-off"
The function displayed in function cannot be used with the current power state (power-off).
"The last pool_type pool cannot be deleted."
The target resource displayed in obj cannot be deleted because it is the last resource pool of resource pool type pool_type.
"pool type mismatched"
The target resource displayed in obj cannot be registered in the resource pool because it is a resource pool type that cannot be registered.
"already exists in pool name"
The target resource displayed in obj cannot be registered in the resource pool because it is already registered in pool name.
"boot disk"
The boot disk cannot be deleted.
"invalid Redundancy"
The function displayed in function cannot be used as L-Server has been located on a VM host with a disabled HA function.
function cannot be executed, as VMware FT has been set for the target resource.
Or function cannot be executed as VMware FT cannot be configured for the target resource.
"Network pool,Address pool,and Image pool"
The target resource cannot be included when calculating the number of L-Servers creatable for each L-Server template.
"VirtualStorage[virtual storage...]", "Pool[storage pool...]", "VirtualStorage[virtual storage],Pool[storage pool]"
The name of the virtual storage resource is displayed in virtual storage.
The name of the storage pool name is displayed in storage pool.
For the function displayed for function, it is not possible to specify system disks and data disks with differing virtual storage or storage pools.
"vmhost[vmtype]"
In vmhost, the VM host name is displayed.
The VM type for the vmhost is displayed in vmtype.
Migration cannot be performed when the VM types of the L-Server and the VM host specified as the migrate destination are different.
"spare server"
Since the operation target resource is a spare server, registration in the server pool cannot be performed.
"some settings exist"
Registration in the server pool cannot be performed because the target operation resource already has an OS installed, or some settings such as I/O virtualization have been configured.
"VMType", "Model", "CPU", "Memory", "Policy.Positioning", "NICs", "Disks.Disk.type", "Policy.SpareSelection", "CPU.NumOfCPU", "CPU.CPUPerf", "Memory.MemorySize", or "FCConnectionPattern"
The above tabs specified in the L-Server template cannot be imported, as they are not supported.
When importing an L-Server template for a physical L-Server, if the following elements are displayed, there is an inconsistency in combinations with other elements described in the XML file.
CPU
Memory
CPU.NumOfCPU
CPU.CPUPerf
Memory.MemorySize
Disks.Disk.type
"Not connected PhysicalServer"
Operation cannot be performed, as the physical server is not connected due to changes to physical server usage.
"VIOM"
HBA address rename settings cannot be configured for the server displayed in obj as a virtualization method has been already configured using VIOM.
"Not Physical Server"
This command can only be performed for the physical L-Server.
Execute this command for the physical L-Server.
"setting VIOM server profile"
In the chassis mounting the server displayed in obj, setting of VIOM is not possible because a server with a virtualization method configured using HBA address rename already exists.
"Network Parameter Auto-Configuration is enabled"
Failed to configure the IP address of the public LAN. The specified cloning images cannot be used, as ROR VE network parameter settings are valid.
"Invalid target network admin LAN"
Failed to configure the IP address of the public LAN. IP addresses cannot be configured for the admin LAN.
"Target network overlaps with admin LAN"
Failed to configure the IP address of the public LAN. The same network as the admin LAN cannot be configured for the public LAN.
When obj is something other than "Target network overlaps with admin LAN"
You are trying to use a function that is not supported by obj, or a function that cannot be used because the status is invalid.
"Invalid agent version"
Failed to configure the IP address of the public LAN. As an agent of a version earlier than ServerView Resource Orchestrator V2.2.1 has been installed, it is not possible to configure a public LAN IP address on the specified cloning image.
When creating a physical L-Server, the IP address cannot be automatically configured if a Red Hat Enterprise Linux image is specified.
When using the created L-Server, manually configure the public LAN IP address.
"disk link"
The DiskLink element cannot be specified in XML for disks with the disk number 0.
"disk copy"
The DiskCopy element cannot be specified in XML for disks with the disk number 0.
"disk link, copy"
The DiskLink element and the DiskCopy element cannot be specified in XML for a single disk at the same time.
"disk type"
The value specified for "type" cannot be set for disks other than disk number 0.
"DiskLink" or "DiskCopy"
An L-Server cannot be created, as the above elements are not supported when creating an L-Server.
"MacAddress"
The operation cannot be performed because the L-Server function displayed in function does not support the above elements.
"release MacAddress" or "reserve MacAddress"
[KVM]
Addition and deletion of NICs and changing of VM type are not possible because the following operations are not supported.
Allocating of a MAC address from the address pool of Resource Orchestrator when modifying virtual L-Server configuration definition information
Releasing of the MAC address allocated from the address pool of Resource Orchestrator
"illegal disk type"
Configurations cannot be changed, since the specified disk resource is not the disk resource of a VM guest.
"disk unregistration"
Try to release disk resource registration using a configuration modification operation.
"Not Virtual Machine" or "Physical Server"
Usage is not possible for physical L-Servers.
"already in use"
A disk that is already being used exclusively by an L-Server cannot be attached to another L-Server.
"last" or "logical server not found"
The function cannot be executed, since operations not supported by the target resources were specified.
"hierarchizing of Tenant folder"
As the hierarchizing of tenant folders is not supported, tenant folders cannot be created in, or moved into, a tenant folder.
"invalid Repurpose"
function cannot be executed, as the resource to be operated does not support the XML tag in detail.
"already in use"
A virtual machine, a physical server, or a disk that is already being used exclusively by an L-Server cannot be connected to another L-Server.
"VM Type", "VMType", or "VM type"
The target resource displayed in obj is server virtualization software that does not support function.
[VMware]
For VMware ESXi, the following operation is not supported.
Backup
[Xen]
The following operation is not supported.
Overcommit
[Oracle VM]
The following operation is not supported.
Creation of an L-Server without specifying a cloning image
Overcommit
[Solaris Containers]
The following operation is not supported.
Creating and deleting an L-Server
Modifying L-Server specifications
Modifying the basic information of L-Servers
Attaching and detaching disks of L-Servers
Console Screen Acquisition of L-Servers
Operations of cloning image
Operations of snapshot
Migration of a VM guest to a different VM host
Allocating and releasing resources of L-Servers
"illegal disk type"
The disk type is not supported.
"not creatable storage"
Disk resources cannot be automatically generated on the target storage device.
"can not delete the static disk"
The LUN created in advance cannot be deleted.
"VIOM is required"
When allocating disk resources to physical L-Servers from multiple storage chassis, VIOM is necessary.
"subnet"
The subnet address of the admin LAN resource that is directly connected from the manager cannot be changed.
"mask"
The subnet mask of the admin LAN resource that is directly connected from the manager cannot be changed.
"DefaultGateway"
The default gateway of the admin LAN resource that is directly connected from the manager cannot be changed.
When obj is "network_resource_name" and detail is "AddressSet"
The subnet address of a resource of the admin LAN directly connected to a manager cannot be specified.
When obj is "network_resource_name" and detail is "ManagementLanSubnet"
Subnet addresses of the admin LAN cannot be used for public LAN resources.
The <ManagementLanSubnet> tag cannot be specified when the <Type> tag to specify the network resource type is not set.
When obj is "network_resource_name" and detail is "Pool"
The specified Pool element cannot be specified when changing network resource settings.
obj is "network_resource_name" and detail is "Vlanautosetting"
Automatic VLAN configuration flags for external connection ports cannot be changed.
When obj is "UserGroup", and detail is "supervisor group"
The "supervisor" group cannot be edited and deleted.
"Pool"
The resource pool cannot be specified.
"Type"
The network resource type cannot be specified.
"Vlanid"
The VLAN ID cannot be specified.
"other tenant folder"
A resource that is being used by a powered on L-Server cannot be moved to another tenant.
Stop the L-Server before moving the resource.
The following resources cannot be moved:
Powered on L-Servers
Folders that contain powered on L-Servers
Resource pools used by powered on L-Servers
Folders or resource pools that contain resource pools used by powered on L-Servers
"The resources used are permission denied."
Access authority is necessary for some resources displayed in obj, which are used by the L-Server.
Check the status of the resources used by the L-Server.
"storage is not configured properly"
The function displayed in function cannot be used as the storage has not been configured properly.
"unknown disk"
function cannot be executed, as there is an unknown disk on the resource to be operated.
"converted vm" or "converted server"
function cannot be executed, as the resource to be operated is an L-Server linked to either a configured physical server or a virtual machine.
"secondary vm of VMware FT"
function cannot be executed, as the resource to be operated is a VMware FT secondary virtual machine.
"exist spare server settings"
function cannot be executed, as the resource to be operated is a physical server for which a spare server has been configured.
"agent is not registered"
function cannot be executed, as there is no registered agent.
"Server pool,Storage pool,Network pool,Address pool,and Image pool"
The operation is valid for VM pools.
The elements in the resources registered in the resource pool cannot be displayed for the resource to be operated.
Reserve information for configuring HA cannot be displayed, as the resource to be operated is not a VM pool.
Overcommit attribute is only valid for VM pools.
"VM pool,Server pool,Network pool,Address pool,and Image pool"
The operation is valid for Storage pools.
Thin provisioning attribute is only valid for Storage pools.
"over_commit is defined in pool.rcxprop"
When using admin server that is upgraded from ROR V2.3 or V3.0 and the upgrade procedures for overcommit are not executed, configuration of the overcommit attribute is not supported. edit the definition file. Refer to "G.1.1 Over Commit Definition File" of the "Setup Guide CE" for more details.
"thin_provisioning is defined in pool.rcxprop"
When using admin server that is upgraded from ROR V2.3 or V3.0 and the upgrade procedures for overcommit is not executed, configuration of the thin provisioning attribute is not supported. Alterntatively, edit the definition file. Refer to "G.1.1 Over Commit Definition File" of the "Setup Guide CE" for more details.
"Server pool,Network pool,Address pool,and Image pool"
The operation is valid for VM and Storage pools.
The setting for displaying the attributes is only valid for VM and Storage pools.
"Server pool,Storage pool,Network pool,Address pool,and Image pool"
The operation is valid for VM pools and server pools.
The resource to be operated cannot be displayed linked to L-Servers.
"VM pool,Server pool,Storage pool,Network pool,and Address pool"
The operation is valid for image pools.
The target resource cannot display image information.
When registering resources to a resource pool, and "force" is displayed
function cannot be executed, as the force option is not supported for resources other than server pools.
"Dynamic Memory is enabled"
Dynamic memory settings are enabled for the target resource.
Memory capacity cannot be changed for L-Servers for which dynamic memory settings are enabled.
"Exist"
When the VM type is something other than KVM, the Exist element cannot be specified.
"DiskLink and ServerImageLink.disk cannot be specified at the same time"
When the L-Server template with the "setting for disk deployment when specifying an image" is specified, a disk which was created (and saved) from virtual storage cannot be specified.
"remaining disk"
For the specified L-Server, a disk which was created (and saved) from virtual storage cannot be specified. The disk can be only specified for virtual L-Servers with the Hyper-V VM type.
"L-Server with snapshot"
Saved virtual disks (created from virtual storage) cannot be added to an L-Server from which a snapshot has been collected.
"not connectable disk resource from VM host"
Virtual disks that cannot be connected to from a VM host with an L-Server deployed cannot be specified.
"disk with snapshot"
deny_deldisk=true(do not delete) cannot be specified for the disk from which a snapshot has been collected.
"product version of VM management software"
In environments where an SCVMM that has not been upgraded to Microsoft(R) System Center 2012 Virtual Machine Manager or later is being used, one of the following operations was performed:
Connection of the L-Server to a disk that was allocated from a virtual storage and saved
Detachment (without deletion) of a disk that was allocated from a virtual storage and saved, from an L-Server.
"disk size, exist"
When the VM type is KVM and the DiskSize element is specified, specify "true" for the Exist element.
"disk link, exist"
When a disk resource created in advance is specified, "false" cannot be specified for the Exist element.
"L-Platform", "Folder", or "Tenant Folder"
The function displayed in function cannot be used with the L-Platform.
"Folder.[tag name]"
The specified resources cannot be created on resource folders or an L-Platform.
"belongs to L-Platform"
The function displayed in function cannot be used with the resources of an L-Platform.
"can not belongs to L-Platform"
Target resources cannot be created on or moved to the L-Platform.
"deny_deldisk=true is specified"
In a specified L-Server, when detaching a disk allocated from virtual storage, the disk is deleted.
"HBA address rename cannot use FCConnectionPattern."
FCConnectionPattern cannot be used in an environment where the HBA address rename service is configured.
"The resource is registered in pool"
The server displayed in obj is registered in the resource pool, so the boot agent cannot be changed.
"no disk configuration information"
Disk information may have not been obtained, because periodic queries to the VM management software has not been done. Wait for a short while and then repeat the operation.
"agent not available"
The function displayed in function cannot be used because the target managed server displayed in obj is a server that cannot use agents.
"agent available"
The target managed server displayed in obj cannot be registered as the VM host that cannot use agents because it has been registered as a server that can use agents.
"HA is required for AliveMonitoring"
When alive monitoring is enabled, None cannot be specified for the Redundancy element.
"Out of DHCP range"
The IP address displayed in obj is out of the range of IP addresses for which the backup and restore functions for system images can be used.
"invalid switchover method"
Server switchover using backup and restore cannot be used for the server displayed for obj.
This is displayed when a VM host is operating on the server displayed for obj.
"invalid model"
The target of operation displayed for obj is a model that does not support function.
"invalid destination"
The VM guest displayed for obj does not support movement to the VM host specified as the destination.
"VM type"
The target of operation displayed for obj is server virtualization software that does not support function.
"OS type"
The target of operation displayed for obj is a server OS that does not support function.
"incompatible network devices"
The NIC configuration of the target of operation displayed for obj does not match the conditions for spare servers of function.
"incompatible IBP group configuration between switch-1 and switch-2"
The IBP group settings of the switch switch-1 of the switchover source, and the switch switch-2 of the switchover target that is displayed for obj do not match the operation conditions of function.
"incompatible mode between switches switch-1 (mode-1) and switch-2 (mode-2)"
The modes of the switch switch-1 of the switchover source, and the switch switch-2 of the switchover target that is displayed for obj do not match.
The modes of each switch, "IBP mode", "switch mode", or "end-host mode" is displayed for mode-1 and mode-2.
"VIOM"
As the server displayed for obj already has VIOM coordination configured as its virtualization method, HBA address rename cannot be set.
"invalid deployment configuration"
The function displayed for function is one not supported in the current environment. For details of backup and restore, and cloning, use ServerView Deployment Manager. For Virtual I/O (HBA address rename), please use ServerView Virtual-IO Manager.
When this message is displayed for other operations, it is not necessary to perform those operations.
For "difference of NIC setting for Admin LAN"
When the settings of the NIC for the admin LAN are a server different to that displayed for obj, configuration of a spare server is not possible.
"Manager is Linux"
This cannot be used with a Linux manager.
"L-Server is "defined" status"
Specified L-Server cannot be operated because of the "defined" status.
[Corrective Action]
When obj is "Target network overlaps with admin LAN"
After creating a physical L-Server, configure the IP address manually. Configure the admin and public LANs in different networks.
When obj is something other than "Target network overlaps with admin LAN"
No action is necessary.
When detail is "VMType", "Model", "CPU", "Memory", "Policy.Positioning", "NICs", "Disks.Disk.type", "Policy.SpareSelection", "CPU.NumOfCPU", "CPU.CPUPerf", "Memory.MemorySize", or "FCConnectionPattern"
Review the L-Server template to see if the above elements are used, and then perform the operation again.
If the following elements are displayed, review the XML file and perform the operation again.
CPU
Memory
CPU.NumOfCPU
CPU.CPUPerf
Memory.MemorySize
Disks.Disk.type
When obj is "network_resource_name" and detail is "AddressSet"
Specify the subnet name of the admin LAN, and perform the operation again.
When obj is "network_resource_name" and detail is "ManagementLanSubnet"
Specify a different value for the subnets of the admin and public LANs, and perform the operation again.
When creating a network resource for the admin LAN using the public LAN subnet, add the <Type>admin</Type> tag, and specify the <ManagementLanSubnet> tag.
When obj is "network_resource_name" and detail is "Pool"
After deleting the Pool element, perform the operation again.
obj is "network_resource_name" and detail is "Vlanautosetting"
Delete vlanautosetting from the ExternalPorts element in the XML definition and then perform the operation again.
When obj is "DefaultGateway" and detail is "ManagementLanSubnet name = "" , Type = admin"
For the admin LAN connected directly to a manager, do not specify the default gateway.
When function is "convert L-Server" and detail is "storage is not configured properly"
Check that the storage has been configured for linking the configured physical server to the L-Server.
When detail is "some settings exist"
When registering a configured physical server to a resource pool, specify the -force option and perform the operation again.
When detail is "Dynamic Memory is enabled"
When changing the memory capacity with dynamic memory enabled
Perform the operation using VM management software.
The changed values are reflected on the configuration of the L-Server by periodic queries made to the VM management software.
For details on the reflection of L-Server configuration by periodic queries, refer to "17.2 Modifying an L-Server" of the "User's Guide for Infrastructure Administrators (Resource Management) CE".
When changing the memory capacity using Resource Orchestrator
Change the settings of the target virtual machine to static memory using VM management software.
After the change has been reflected on the L-Server, perform the operation again.
When detail is "release MacAddress" or "reserve MacAddress"
After deleting the L-Server, create an L-Server again.
When detail is "illegal disk type"
Specify a disk resource for VM guest, and perform the operation again.
When detail is "disk unregistration"
Use the unregister command to release the registration of obj disk resources, and perform the operation again.
When detail is "L-Platform"
Perform the operation, using the command for L-Platforms.
When detail is "Folder"
Create a resource, using the command for the resource folder.
When detail is "Tenant Folder"
Perform the operation, using the command for tenants.
When detail is "belongs to L-Platform"
when you change the setting of the alive monitoring to L-Server disposed from L-Platform, use the XML file that contains only the tag of the alive monitoring setting and redundancy.
When detail is "can not belongs to L-Platform"
Specify the resource folder or tenant folder for the creation or destination resource folder, and perform the operation again.
When detail is "deny_deldisk=true is specified"
In the specified L-Server, when detaching a disk allocated from virtual storage, the disk is deleted.
To reduce, specify deny_deldisk=false. The deny_deldisk argument may also be omitted.
The -deny_deldisk=true argument can only be specified when detaching disks from physical L-Servers or virtual L-Servers with the VM type Hyper-V.
When detail is "DiskLink and ServerImageLink.disk cannot be specified at the same time"
Modify the L-Server template or change the setting so that disks which were created (and saved) from virtual storage will not be used, and then perform the operation again.
When detail is "remaining disk"
Review the VM type and environment, and then perform the operation again.
When detail is "L-Server with snapshot"
When adding a saved virtual disk (created from virtual storage) to a virtual L-Server, delete all snapshots of that virtual L-Server first, and then perform the operation again.
When detail is "not connectable disk resource from VM host"
Check the VM management software to see if the VM host with an L-Server deployed can connect to virtual disks, and then perform the operation on the L-Server which can connect to virtual disks.
When detail is "disk with snapshot"
When saving a virtual disk (created from virtual storage), delete all snapshots of that virtual L-Server first, and then perform the operation again.
When detail is "product version of VM management software"
Check if the SCVMM being used has been upgraded to Microsoft(R) System Center 2012 Virtual Machine Manager or later. If not, upgrade SCVMM and then perform the operation again.
When detail is " HBA address rename cannot use FCConnectionPattern."
Re-execute without specifying FCConnectionPattern.
When detail is "no disk configuration information"
Regular enquiry to the VM management product it is and there is a possibility that disk information on the image cannot be acquired for the unexecution.
Wait for a short while and then repeat the operation.
When function is "registering agent" and detail is "agent not available"or "agent available"
Perform one of the following corrective actions:
Make the target managed server displayed in obj the server for VM hosts which can use agents by modifying the settings in the definition file explained in the following section. Then, register the agent.
"C.1.5 Configuration when Creating a Virtual L-Server Using VMware ESXi on Other Vendor's Servers" in "Setup Guide CE"
Make the target managed server displayed in obj the server for VM hosts which cannot use agents by deleting that server. After this, register the server and agent, referring to the following section:
"C.1.5 Configuration when Creating a Virtual L-Server Using VMware ESXi on Other Vendor's Servers" in "Setup Guide CE"
When detail is "HA is required for AliveMonitoring"
Specify "HA" for the Redundancy element, and then perform the operation again.
In other cases
This message is displayed because use of an unsupported function was attempted for obj. No action is required.
[Description]
The specified command, subcommand, or option is not supported.
The name of the managed server or the port name is displayed for obj.
The following detailed information is given in detail.
"Manager"
The server displayed for obj is an admin server.
"Port name"
The port name displayed for obj is a port name not supported by Resource Orchestrator.
[Corrective Action]
Perform checks based on each piece of detailed information, if the combination of resources is incorrect or the values differ, change the values specified or the settings and then perform the operation again.
"Manager"
When this message is displayed during registration of a managed server, check that an admin server is not the target of the operation.
If displayed when performing reconfiguration of hardware properties, check that an admin server has not been mounted in the relevant slot.
"Port name"
When changing port numbers, check there are no mistakes in port names.
For how to change port numbers, refer to follwing:
For Virtual Edition, refer to "8.2 Changing Port Numbers" of the "User's Guide VE", or "5.11 rcxadm mgrctl" of the "Reference Guide (Command) VE"
For Cloud Edition, refer to "6.2 Changing Port Numbers" of the "", or "5.14 rcxadm mgrctl" of the "Reference Guide (Command/XML) CE"
[Description]
The specified managed server cannot perform operation against target.
The name of the managed server is displayed for server.
The target operation of server is displayed for target.
[Corrective Action]
Correct the specified target.
[Description]
An error has occurred because the PostgreSQL login user password has been changed.
[Corrective Action]
The configured user password is not correct.
Check the OS password setting conventions, and set an appropriate password.
If this does not resolve the problem, collect troubleshooting information and contact Fujitsu technical staff.
[Description]
The command cannot be executed because the obj1 is defined as type of obj2.
[Corrective Action]
After resolving the problem, perform the operation again.
[Description]
The VM host or VM guest is not supported.
The name of the specified server is displayed for obj.
[Corrective Action]
Specify the physical OS name, and then perform the operation again.
[Description]
The IP address specified is incorrect, or the chassis information specified is not registered on the admin server.
[Corrective Action]
Check the following:
Check that the specified IP addresses of the chassis and server management unit or the server information (such as IP address) are correct.
If there are errors, perform registration again using the correct information.
Check if the chassis is powered on. If the chassis is not powered on, after powering it on, perform registration again.
[Description]
The LAN switch for connection to the network interface of the managed server for registration is not registered.
[Corrective Action]
Register the LAN switch for connection to the network interface of the managed server for registration, and then perform the operation again.
How to check and register the destination LAN switch
For Virtual Edition, refer to "C.1 Connections between Server Network Interfaces and LAN Switch Ports" of the "Design Guide VE", and check the LAN switch to be connected to the NIC of the specified managed server.
Refer to "B.3 Resource Definitions" in the "User's Guide VE", add LAN switch definitions to the system configuration file, and then import it again.
For Virtual Edition, refer to "C.1 Connections between Server Network Interfaces and LAN Switch Ports" of the "Design Guide CE", and check the LAN switch to be connected to the NIC of the specified managed server.
Refer to "B.3 Resource Definitions" in the "User's Guide for Infrastructure Administrators (Resource Management)", add LAN switch definitions to the system configuration file, and then import it again.
[Description]
The slot number or IP address of the specified LAN switch is incorrect.
[Corrective Action]
Check the mounting position of the LAN switch blade and IP address, specify the correct slot number and IP address, and then perform the operation again.
[Virtual Edition]
[Description]
There are multiple resources with the name specified for obj.
Commands cannot be used to operate multiple resources with the same name.
[Corrective Action]
Execute the command after changing the names of resources so no two have the same name.
When it is not possible to change the names of resources with the same name, perform operations from the GUI.
[Cloud Edition]
[Description]
When registering resources to resource pools
obj has already been registered in a resource pool.
When moving resources from the resource pool
A resource that has the same name as obj is registered in the destination resource pool.
When performing user authentication using directory service
obj is already registered in one of the following locations. The names are not-case-sensitive.
Root folder
Same resource folder
Same tenant folder
Inside the same resource pool
When importing the configuration information for the operation of Disaster Recovery environments
There are multiple VM guests or VM hosts specified in obj.
When the name on management software has been changed, reverse the change, and perform the operation again.
When operating network devices
There are multiple network devices specified in obj.
When creating a L-Server, resource pool, folder, or tenant
There are the following possibilities:
A resource with the same name already exists.
When created directly under the orchestration tree, an L-Server template with the same name may exist.
In other cases
There are multiple resources with the name specified for obj.
Commands cannot be used to operate multiple resources with the same name.
[Corrective Action]
When registering resources to resource pools
With Resource Orchestrator, if obj has already been registered in a resource pool, it is displayed because currently registered resources cannot be registered. No action is necessary.
When moving resources from the resource pool
Resources with the same name cannot be registered on this product. Change the resource name and then try again.
When performing user authentication using directory service
A resource with the same name as an already registered resource is displayed, because it cannot be registered at the same time. Change the resource name, and then perform the operation again.
When operating network devices
Execute the command again, referring to "7.4 Changing LAN Switch Settings" of the "User's Guide for Infrastructure Administrators (Resource Management) CE", after changing the network device name using the GUI.
When creating a L-Server, resource pool, folder, or tenant
Change the name and perform creation again.
In other cases
Execute the command after changing the names of resources so no two have the same name.
When it is not possible to change the names of resources with the same name, perform operations from the GUI.
[Description]
Login as a Resource Orchestrator user has not been performed.
[Corrective Action]
Perform the operation again after logging in as a Resource Orchestrator user.
If this message is displayed when executing a command, log in as an administrative user of Resource Orchestrator or with OS administrator authority and perform the operation again.
For details of the authority necessary for executing commands, refer to "Chapter 1 Overview" of the "Reference Guide (Command) VE" or "Reference Guide (Command/XML) CE".
For details of how to log in as an administrative user of Resource Orchestrator, refer to "2.1 rcxlogin" of the "Reference Guide (Command) VE" or "Reference Guide (Command/XML) CE".
When operating managers in clusters, there is a chance that the shared disk for managers is not mounted.
Mount the shared disk for managers on the node the operation was performed on and perform the operation again.
[Description]
A communication error with the manager occurred during execution of a command.
[Corrective Action]
Check the following, resolve the problem, and execute the command again.
Check the Network Environment
How to Check
Check that the port number (service name: rcxweb, default: 23461) used by the admin server for the Resource Coordinator Manager service is not being used for another service.
Execute the following command on the server where a manager is installed to check the usage status of the port number.
Display process IDs using port numbers
Example
[Windows Manager]
>netstat -oan | find "0.0.0.0:23461" <RETURN> TCP 0.0.0.0:23461 0.0.0.0:0 LISTENING 2632 -> Process ID is 2632 |
[Linux Manager]
# netstat -lnp | grep ":23461" <RETURN> tcp 0 0 :::23461 :::* LISTEN 4095/httpd -> Process ID is 4095 |
Check that the process ID belongs to the httpd of Resource Orchestrator
Example
[Windows Manager]
>tasklist /svc /FI "PID eq 2632" <RETURN> Image name PID service ========================= ====== ====================================== httpd.exe 2632 ResourceCoordinatorWebServer(Apache) |
[Linux Manager]
# ps -fp 4095 <RETURN> UID PID PPID C STIME TTY TIME CMD root 4095 1 0 Jul18 ? 00:00:00 /opt/FJSVrcvmr/sys/apache/bin/httpd -k start |
Corrective Action
When it was being used by another service, change the port number to be used.
For how to change port numbers, refer to the follwing:
For Virtual Edition, refer to "8.2 Changing Port Numbers" or "9.1.6 Changing Port Numbers" of the "User's Guide VE".
For Cloud Edition, refer to "6.2 Changing Port Numbers" or "7.1.6 Changing Port Numbers" of the "User's Guide for Infrastructure Administrators (Resource Management)".
When the port number being used by Resource Coordinator Manager is correct, or the corrective action above does not resolve the problem, collect troubleshooting information and contact Fujitsu technical staff.
[Description]
A console control error has occurred in the process in the rcxlogin command for hiding passwords.
[Corrective Action]
If terminal software other than the standard Windows command prompt is being used, check the settings of that software.
If the problem occurs when using the command prompt or the corrective action above does not resolve the problem, collect troubleshooting information and contact Fujitsu technical staff.
[Description]
Operation is not possible as the manager service is running.
The name of one of the running services is displayed for process.
[Corrective Action]
Refer to "2.1 Starting and Stopping the Manager" of the "Operation Guide VE" or "Operation Guide CE", and check whether the "Manager Services" and "Related Services" have been stopped on the admin server. If any server is running, stop it.
After stopping any started services, perform the operation that resulted in the error again.
[Windows Manager]
When operating managers in clusters, there is a chance that the cluster services for the manager and for the HBA address rename setup service are online on the same node.
Check that the cluster services are not online on the same node in the [Failover Cluster Management] window, and migrate the cluster service for the HBA address rename setup service to another node if it is online on the same node.
When other nodes have failed, perform the operation after recovery.