An "initialization processing failure check" task occurs when patch distribution/application initialization processing has failed.
If an "initialization processing failure check" task has occurred, a log will be output to the Details field of the Initialization processing failure check tab window indicating what kind of error has occurred.
Refer to the "returnCode" information. The following table shows the expected values and their meaning:
Keyword | returnCode | Meaning |
---|---|---|
executeCommand<Script path> | Other than 0 | The command may have failed to access the CMDB. Contact the infrastructure administrator to check whether ServerView Resource Orchestrator is running correctly. Then retry the processing in accordance with the infrastructure administrator's instructions. |
All | 189 | If one of the following values has been output for "message", this means that the connection for network communications with the business server has failed: [LinkExpRBA] CategoryCode: 50 [LinkExpRBA] ErrorCode: 80 [Actions] Check the following items:
|
If one of the following values has been output for "message" or "server_check_result", this means that a timeout has occurred during communications with the business server. [LinkExpRBA] CategoryCode: 50 [LinkExpRBA] ErrorCode: 60 [Actions] The following are the possible causes of the problem:
Check these possible causes and then try again. If the situation still does not change despite the retry attempt, collect investigation data using the problem investigation data collection command (swcfmg_collectinfo), and then contact Fujitsu technical support. | ||
If one of the following values has been output for "message", this means that a timeout has occurred during communications with the business server: [LinkExpRBA] CategoryCode: 50 [LinkExpRBA] ErrorCode: 60 [Actions] The following are the possible causes of the problem:
Check these possible causes and then try again. If the situation still does not change despite the retry attempt, collect investigation data using the problem investigation data collection command (swcfmg_collectinfo), and then contact Fujitsu technical support. | ||
Other | Collect investigation data using the problem investigation data collection command (swcfmg_collectinfo), and then contact Fujitsu technical support. |
Make Choice panel
When the Retry button is clicked, the initialization processing will be performed again.