1.25.7 Specify Output of Error Log

Functional Specification

Modify the collected log for investigation (error log).

Command Format

FSW11EJ7.EXE <Password> /L /F /E <Flag> [/Silent]

Option

<Password>:

Enter the password set during installation of the client (CT).

/L:

Perform log output.

/F:

Specify it when outputting to files.

/E:

Specify it when outputting error logs.

<Flag>:

Enter one of the following numbers.

0:

When logs are not to be collected

1:

When logs are to be collected

/Silent:

It is the option that is effective in the OS of Windows Vista® or higher. It can avoid displaying the following message after command execution.

Press any key to continue...

Return Value

0:

[Fixed Value]


Location for Saving Commands

When executing on the PC in which the OS is Windows Server® 2008 64-bit edition, Windows Server® 2008 R2, Windows Vista® 64-bit edition or Windows® 7 64-bit edition

%SystemRoot%\SYSWOW64\FSW11EJ7.EXE

When executing on the PC in which the OS is other than Windows Server® 2008 64-bit edition, Windows Server® 2008 R2, Windows Vista® 64-bit edition or Windows® 7 64-bit edition

%SystemRoot%\system32\FSW11EJ7.EXE

*%SystemRoot% is usually C:/Windows.


Authority Required for Execution/Execution Environment

Notes

Example of Use

c:\>fsw11ej7.exe password /L /F /E 0
[E701-INF001] The command has ended.