[Name]
dsphanet - Displaying the operation status of communication target monitoring
[Synopsis]
/opt/FJSVhanet/usr/sbin/dspobserv [-d]
[Feature description]
The dspobserv command displays the current operation status of communication target monitoring.
[Option]
You can specify the following option.
[-d]
An asterisk (*) is displayed at the end of a physical IP address of the active node that GLS recognizes as a communication target.
[Display format]
The following shows the display formats of monitoring status:
The option is not specified:
# /opt/FJSVhanet/usr/sbin/dspobserv
observ status = ON
interval = 5 sec
times = 5 times
idle = 60 sec
repair_time = 5 sec
fail over mode = YES
Node VIP NIC Status
+----------------+-------------------+-------------------+------+
host1 192.168.100.10 192.168.10.10 ACTIVE
192.168.20.10 ACTIVE
192.168.10.20 ACTIVE
192.168.20.20 ACTIVE |
The option is specified:
# /opt/FJSVhanet/usr/sbin/dspobserv -d
observ status = ON
interval = 5 sec
times = 5 times
idle = 60 sec
repair_time = 5 sec
fail over mode = YES
Node VIP NIC Status
+----------------+-------------------+-------------------+------+
host1 192.168.100.10 192.168.10.10* ACTIVE
192.168.20.10* ACTIVE
192.168.10.20 ACTIVE
192.168.20.20 ACTIVE |
Display | Contents | |
|---|---|---|
observ status | ON | The monitoring function is enabled. |
OFF | The monitoring function is disabled. | |
interval | In seconds the monitoring interval in the stationary status. | |
times | The monitoring count. | |
idle | Displays in seconds the wait time that elapses after monitoring starts and before the HUB links up. | |
repair_time | Displays the recovery monitoring interval in seconds. | |
fail over mode | YES | If the virtual interface is registered in the cluster resource, node switching is performed when all the transfer routes fail. (default) |
NO | If the virtual interface is registered in the cluster resource, node switching is not performed when all the transfer routes fail. | |
VIP | Displays the name of a virtual interface held by the monitored node. | |
NIC | Displays the hostname or IP address of a real interface to be monitored. | |
Status | Active | Monitoring is in progress. |
FAIL | Monitoring failed (recover monitoring in progress). | |
---- | The monitoring function is disabled. | |
[Related commands]
hanetobserv
[Examples]
The following shows an example of displaying the status of communication target monitoring in GS linkage mode.
# /opt/FJSVhanet/usr/sbin/dspobserv |