Device Information files are created in CSV format in which items are separated by a comma. In addition, since the first line is used as item name, please output actual data from the second line.
Items and file examples recorded in files are shown as below.
Item
No. | Item name | Mandatory/Optional | Characters that can be specified | Remark |
|---|---|---|---|---|
1 | Asset Number | Mandatory (note) | Up to 24 characters can be set including DBC case alphanumeric characters and DBC case symbols. Letters are not case-sensitive. Letters are treated as capital letters for registration or modify when using lowercase letters. For example, modify “a001” as “A001”.
| Asset Number of machine |
2 | Model Name | Optional | Up to 64 characters can be set including DBC case alphanumeric characters, DBC case symbols and SBC case multi-byte characters. | Model name of machine |
3 | Serial Number | Optional | Up to 24 characters can be set including DBC case alphanumeric characters, DBC case symbols and SBC case multi-byte characters. | Serial name of machine |
4 | Manufacturer Name | Optional | Up to 64 characters can be set including DBC case alphanumeric characters, DBC case symbols and SBC case double-byte characters. | Manufacturer name of machine |
5 | Class | Mandatory | Up to 32 characters can be set including DBC case alphanumeric characters, DBC case symbols and SBC case multi-byte characters. In addition, when “PC” is set, error will occur if “machine name” and “user ID” are the same as other registered PC. | Class of mahcine |
6 | Type | Mandatory | Up to 64 characters can be set including DBC case alphanumeric characters, DBC case symbols and SBC case multi-byte characters. | Details of mahcine class |
7 | Propertyt ID | Optional | Up to 64 characters can be set including DBC case alphanumeric characters, DBC case symbols and SBC case double-byte characters. | Property type of machine |
8 | User ID | Mandatory | Up to 20 characters can be set including DBC case alphanumeric characters and DBC case symbols. | User ID of user that is using the machine. Error will occur when setting value that is not registered to Systemwalker Desktop Patrol. |
9 | Device name | Mandatory | Up to 20 characters can be set including DBC case characters and SBC case characters. | Name for use of machine |
10 | Contract No. | Optional | Up to 20 characters can be set including DBC case alphanumeric characters and DBC case symbol (“-”). | Number of lease contract or rent contract related to machine. Error will occur when setting value that is not registered as contract information. |
11 | Maintainance code | Optional | Up to 20 characters can be set including DBC case alphanumeric characters and DBC case symbol (“-”). | Number of maintenance contract related to machine. Error will occur when setting value that is not registered as contract information. |
12 | Usage status | Optional | Set any of the following items according to usage status.
| Usage statusof machine |
13 | Inherent information(1~30) | Optional | Up to 64 characters can be set including DBC case alphanumeric characters, DBC case symbols and SBC case multi-byte characters. | Any information related to machine. |
14 | Path Name of Link | Optional | Up to 255 characters UNC presentation can be used for setting. Path name or URL of directory also can be set except path name of files. In case a path is specified to start with “http:” or “https:”, it is determined as URL without detecting if the file exists. | Related machine data (e.g. machine image) or these input directory and URL. |
15 | IP Address 1 | Optional | Set in following format. XXX.XXX.XXX.XXX XXX: DBC case numbers from 0~255 can be set. |
|
16 | MAC Address 1 | Optional | Set in following format. XX:XX:XX:XX:XX:XX XX: only hex presentation from 00 - FF can be set. DBC case letters can be set as capital or lowercase. Separators can be as “_”. In addition, separators can be omitted for setting. When separator “_” is omitted, separator “:” will be registered in machine management ledger. Setting example: FF:0B:5D:D0:D7:13 FF-0B-5D-D0-D7-13 FF0B5DD0D713 |
|
17 | IP Address 2 | Optional | Set in following format. XXX.XXX.XXX.XXX XXX: DBC case numbers from 0~255 can be set. |
|
18 | MAC Address 2 | Optional | Set in following format. XX:XX:XX:XX:XX:XX XX: only hex presentation from 00 - FF can be set. DBC case letters can be set as capital or lowercase. Separators can be as “_”. In addition, separators can be omitted for setting. When separator “_” is omitted, separator “:” will be registered in machine management ledger. Setting example: FF:0B:5D:D0:D7:13 FF-0B-5D-D0-D7-13 FF0B5DD0D713 |
|
19 | Setup Place | Optional | Up to 60 characters can be set including DBC case alphanumeric characters, DBC case symbols and SBC case multi-byte characters. | Set the setup place of machine. Error will occur when setting value that is not registered to “building management information”. |
20 | Related Asset Number | Optional | Up to 24 characters can be set including DBC case alphanumeric characters and DBC case symbols. Letters are not case-sensitive. Letters are treated as capital letters for registration or modify when using lowercase letters. For example, modify “a001” as “A001”. In addition, in case related asset number is not input, the value that is the same as the asset Number will be related asset number. In case following related asset number is input, input value error will occur.
| |
21 | Date of Manufacture | Optional | Up to 20 characters can be set including DBC case alphanumeric characters, DBC case symbols and SBC case multi-byte characters. | Manufacture date of device |
22 | Date of Registration | Optional | Up to 20 characters can be set including DBC case alphanumeric characters, DBC case symbols and SBC case multi-byte characters. | Registration date for device property device account. |
23 | Inherent information (31~60) | Optional | Up to 64 characters can be set including DBC case alphanumeric characters, DBC case symbols and SBC case multi-byte characters. | Any information related to machine |
Note) when auto setting of assets management number is started, the automatically set property management number will be stochastic, and it will be automatically set in “Assets Management number setting” tab of “Environment Setup” window.
Remarks: in case “contract No.” or “maintenance code” of register/modify machine is not set, the section administrator can only set the section to which he belongs, the subordinate section or unconfigured “user ID” when registering/modifying property information.
Example
Asset Number,Model Name,Serial Number,Manufacturer Name,Class,Type,Asset Classification,User ID,Device Name,Contract No.,Mainte Code,Availability,User Memo1,User Memo2,User Memo3,User Memo4,User Memo5,User Memo6,User Memo7,User Memo8,User Memo9,User Memo10,User Memo11,User Memo12,User Memo13,User Memo14,User Memo15,User Memo16,User Memo17,User Memo18,User Memo19,User Memo20,User Memo21,User Memo22,User Memo23,User Memo24,User Memo25,User Memo26,User Memo27,User Memo28,User Memo29,User Memo30,Path Name of Link,IP Address 1,MAC Address 1,IP Address 2,MAC Address 2,Setup Place,Related Asset Number,Date of Manufacture,Date of Registration,User Memo31,User Memo32,User Memo33,User Memo34,User Memo35,User Memo36,User Memo37,User Memo38,User Memo39,User Memo40,User Memo41,User Memo42,User Memo43,User Memo44,User Memo45,User Memo46,User Memo47,User Memo48,User Memo49,User Memo50,User Memo51,User Memo52,User Memo53,User Memo54,User Memo55,User Memo56,User Memo57,User Memo58,User Memo59,User Memo60 A-000000030,FMV7TXJ121,MA1500428,FUJITSU,PC,Client, lease property, fujitsugoro,CT30,Lease0001,,In use,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, A-000000067,FMV7TXJ121,MA1500428,FUJITSU,PC,server, lease property, fujitsugoro,CT67,Lease0001,,In use,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, |