Systemwalker Desktop Patrol V14g Operation Guide: for Administrators
Systemwalker

3.1.4 Perform Settings of PC Operation Management

When using the PC operation management function, it is required to perform the following settings on CS and the PC to perform operation management.

3.1.4.1 Settings of CS

Perform the following settings on CS.

3.1.4.2 Settings of Operation Management Target PC

Perform the following setting on the BIOS settings window of the PC to perform operation management. For information on how to display the BIOS settings window, please refer to the manual of PC itself.

  1. Startup of ME BIOS (Start the window such as AMT settings .etc)

  2. Settings of Intel® ME Configuration

  3. Settings of Intel® AMT Configuration

For method of setting, please refer to the manual of PC to perform operation management.


Example of setting in case of FMV-D5330

The method of setting on FMV-D5330 is as follows.


Start ME BIOS

Start according to the following procedure.

  1. Turn on the power of PC and start the PC.

  2. After the “FUJITSU” logo is displayed, “Press <Ctrl-P> to enter Intel® ME Setup” will be displayed on the window. At this time, press [Ctrl] and [P] at the same time.

  3. The setting window of “Intel ® ME Configuration”, “Intel ® AMT Configuration” will be displayed. After “Intel® ME Password” is displayed, enter the following password.


Settings of Intel® ME Configuration

After ME BIOS is started, perform password authentication, select “Intel ® ME Configuration”, and perform the following settings. Please do not modify other settings.

Setting Items

Setting Value

Intel® ME Power Control

Intel® ME State upon Initial Power-On

ON

Intel® ME ON in Host Sleep States

ALWAYS

Setting Procedure

  1. Select “Intel® ME Configuration”.

  2. Select “Intel® ME Power Control”. In setting items, select the following two items separately and perform settings.

    • Intel® ME State upon Initial Power-On

    • Intel® ME ON in Host Sleep States

  • Select “Return to Previous Menu”.

  • Select “Return to Previous Menu”.


Settings of Intel® AMT Configuration

After starting ME BIOS, please execute password authentication and select “Intel ® AMT Configuration” to perform the following settings. Please perform settings according to the sequence of “Provision Model”, “TCP/IP”. Please do not modify other settings.

Setting Items

Setting Value

Required/Optional

Provision Model

-

Intel AMT 2.0 Mode
(Note)

-

Small Business
(Note)

TCP/IP

Network Interface

Enable
(Note)

DHCP

Disable
(Note)

IP address

IP address

Subnet mask

Subnet mask

Default Gateway address

Default gateway

Preferred DNS address

Preferred DNS

Alternate DNS address

DNS

Domain Name

Domain name

◎: Required item

○: Optional item (Please set a value that is same as the network settings of OS.)

Note) Whether to modify the current setting value, select yes (Y) or no (N).


Setting Procedure

  1. Select “Intel® AMT Configuration”.

  2. In setting items, select “Provision Model”, the following items will be displayed in sequence. Please perform settings in sequence. (After settings have been completed, “Provision Model” will disappear from the list of setting items.)

    • Intel® AMT 2.0 Mode

    • Small Business

  3. In setting items, select “TCP/IP”. The following setting items will be displayed in sequence, please perform settings separately.

    • Network Interface

    • DHCP

    • IP address

    • Subnet mask

    • Default Gateway address (If not to set, please click [Enter] directly)

    • Preferred DNS address (If not to set, please click [Enter] directly)

    • Alternate DNS address (If not to set, please click [Enter] directly)

    • Domain Name (If not to set, please click [Enter] directly)

  4. Select “Return to Previous Menu”

  5. Select “Exit”

    Note

    In the OS and AMT to perform operation management of PC, fixed IP address should be assigned separately. Please do not perform DHCP settings in OS and AMT.