Event traps are messages reported from a device. If you have any questions about the message contents, refer to the instruction manual for hardware to take corrective actions.
Notification of component blockage
Target | Level | Event display | Remarks |
---|---|---|---|
CM Unit | Error | P 01SSMM00 Controller Module(CM xxHz zz yyPort)#MM<pp ss rr> Fault | SS : Parts subtype |
CM BE Expander | Error | P 06SSMM00 Controller Module(CM xxHz zz yyPort)#MM<pp ss rr> BE Expander Fault | SS : Parts subtype |
CM SAS Port | Error | P 09SSMMnn Controller Module(CM xxHz zz yyPort)#MM<pp ss rr> SAS Port Fault | SS : Parts subtype |
CM BE Expander Port | Error | P 0ASSMMnn Controller Module(CM xxHz zz yyPort)#MM<pp ss rr> BE Expander Port#nn Fault | SS : Parts subtype |
CM Memory:512MB | Error | P 0B01MM00 Controller Cache(MEM-512MB)#MM<pp ss rr> Fault | MM : Module ID(10-11) |
CM Memory:1GB | Error | P 0B02MM00 Controller Cache(MEM-1GB)#MM<pp ss rr> Fault | MM : Module ID(10-11) |
CM Memory:2GB | Error | P 0B04MM00 Controller Cache(MEM-2GB)#MM<pp ss rr> Fault | MM : Module ID(10-11) |
CM Flash ROM | Error | P 0CSSMM00 Controller Module(CM xxHz zz yyPort)#MM<pp ss rr> Flash ROM Fault | SS : Parts subtype |
CM FAN Unit | Error | P 0D00MM00 Cooling Fan(BLOWER FAN)#MM<pp> Fault | MM : Module ID(10-11) |
CA Port | Error | P 11SSMMnn Controller Module(CM xxHz zz yyPort)#MM<pp ss rr> Host Port#nn Fault | SS : Parts subtype |
CM FE Expander | Error | P 12SSMM00 Controller Module(CM xxHz zz yyPort)#MM<pp ss rr> FE Expander Fault | SS : Parts subtype |
CM FE Expander Port | Error | P 13SSMMnn Controller Module(CM xxHz zz yyPort)#MM<pp ss rr> FE Expander Port#nn Fault | SS : Parts subtype |
SFP Optical Shortwave | Error | P 1A00MMnn FC SFP CM#MM Port#nn<pp ss rr oo> Fault | MM : Module ID(10-11) |
BBU | Error | P 750000nn Battery Unit(BBU) Slot#nn<pp ss rr> Fault | nn : Slot No.(0-1) |
3.5 Inch DISK | Error | P 80SSDDnn Disk Drive(HDD-xxxGB-yykrpm) DE#DD/Slot#nn<pp ss rr cc> Fault | SS : Parts subtype |
3.5 Inch Disk | Error | P 80SSDDnn Disk Drive(HDD-xxxGB-yykrpm) DE#DD/Slot#nn<pp ss rr cc> FailedUse | SS : Parts subtype |
3.5 Inch DISK | Error | P 88SSDDnn Disk Drive(HDD-xxxGB-yykrpm) DE#DD/Slot#nn<pp ss rr cc> Fault | SS : Parts subtype |
2.5 Inch DISK | Error | P 81SSDDnn Disk Drive(HDD-xxxGB-yykrpm) DE#DD/Slot#nn<pp ss rr cc> Fault | SS : Parts subtype |
2.5 Inch Disk | Error | P 81SSDDnn Disk Drive(HDD-xxxGB-yykrpm) DE#DD/Slot#nn<pp ss rr cc> FailedUse | SS : Parts subtype |
2.5 Inch DISK | Error | P 88SSDDnn Disk Drive(HDD-xxxGB-yyKrpm) DE#DD/Slot#nn<pp ss rr cc> Fault | SS : Parts subtype |
3.5 Inch DISK | Error | P 82SSDDnn Disk Drive(HDD-xxxGB-SATA) DE#DD/Slot#nn<pp ss rr cc> Fault | SS : Parts subtype |
3.5 Inch Disk | Error | P 82SSDDnn Disk Drive(HDD-xxxGB-SATA) DE#DD/Slot#nn<pp ss rr cc> FailedUse | SS : Parts subtype |
3.5 Inch DISK | Error | P 88SSDDnn Disk Drive(HDD-xxxGB-SATA) DE#DD/Slot#nn<pp ss rr cc> Fault | SS : Parts subtype |
2.5 Inch DISK | Error | P 83SSDDnn Disk Drive(HDD-xxxGB-SATA) DE#DD/Slot#nn<pp ss rr cc> Fault | SS : Parts subtype |
2.5 Inch Disk | Error | P 83SSDDnn Disk Drive(HDD-xxxGB-SATA) DE#DD/Slot#nn<pp ss rr cc> FailedUse | SS : Parts subtype |
2.5 Inch DISK | Error | P 88SSDDnn Disk Drive(HDD-xxxGB-SATA) DE#DD/Slot#nn<pp ss rr cc> Fault | SS : Parts subtype |
EXP | Error | P 9001DD0N Expander(EXP) DE#DD/Group#nn<pp ss rr> Fault | DD : DE-ID |
EXP Port | Error | P 9100DDNn Expander(EXP) DE#DD/Group#N/Port#m<pp ss rr> Fault | DD : DE-ID |
EXP FAN | Error | P 9200DD0N Cooling Fan(BLOWER FAN) DE#DD/Group#nn<pp> Fault | DD : DE-ID |
DE FANU | Error | P D100DD0N Cooling Fan(ENC FAN) DE#DD/Slot#nn<pp> Fault | DD : DE-ID |
PSU | Error | P D200DD0N Power Supply(PSU) DE#DD/Slot#nn<pp ss rr> Fault | DD : DE-ID |
Warning (temperature alarm)
Target | Level | Event display | Remarks |
---|---|---|---|
DE Abnormal exhaust gas temperature | Error | P DA0tDD00 DE OUT TEMP | t : Type(1=1U, 2=2U) |
DE Abnormal exhaust gas temperature | Error | P DA0tDD00 DE OUT TEMP | t : Type(1=1U, 2=2U) |
DE Abnormal exhaust gas temperature | Warning | J DA0tDD00 DE OUT TEMP | t : Type(1=1U, 2=2U) |
DE Abnormal intake temperature | Error | P DB0tDD00 DE IN TEMP | t : Type(1=1U, 2=2U) |
DE Abnormal intake temperature | Warning | J DB0tDD00 DE IN TEMP | t : Type(1=1U, 2=2U) |
Warning (expiration)
Target | Level | Event display | Remarks |
---|---|---|---|
BATTERY six months prior to expiry | Warning | J 700600nn BATTERY n 6MONTH WARNING YYYY/MM | nn : Slot No. |
BATTERY one week prior to expiry | Warning | J 700700nn BATTERY n 1WEEK WARNING YYYY/MM | nn : Slot No. |
BATTERY n day(s) prior to expiry | Warning | J 700700nn BATTERY n dDAY WARNING YYYY/MM | nn : Slot No. |
BATTERY expiry | Warning | J 70FE00nn BATTERY n EXPIRATION ALARM YYYY/MM | nn : Slot No. |
Warning (other)
Target | Level | Event display | Remarks |
---|---|---|---|
CM Check1 | Warning | J C1MM0000 Controller Module(CM xxHz zz yyPort)#MM<pp ss rr> Check-1 | MM : Module ID(10-11) |
Multiple memory collectable error:512MB | Warning | J C301MM00 Controller Cache(MEM-512MB)#MM<pp ss rr> Correctable Error | MM : Module ID(10-11) |
Multiple memory collectable error:1GB | Warning | J C302MM00 Controller Cache(MEM-1GB)#MM<pp ss rr> Correctable Error | MM : Module ID(10-11) |
Multiple memory collectable error:2GB | Warning | J C304MM00 Controller Cache(MEM-2GB)#MM<pp ss rr> Correctable Error | MM : Module ID(10-11) |
CM-Warning | Warning | J 01SSMM00 Controller Module(CM xxHz zz yyPort)#MM<pp ss rr> Warning FACTOR(ww) | SS : Parts subtype |
CM BE Expander Warning | Warning | J 06SSMM00 Controller Module(CM xxHz zz yyPort)#MM<pp ss rr> BE Expander Warning | SS : Parts subtype |
CM SAS Port Warning | Warning | J 09SSMMnn Controller Module(CM xxHz zz yyPort)#MM<pp ss rr> SAS Port#nn Warning | SS : Parts subtype |
CM BE Expander Port Warning | Warning | J 0ASSMMnn Controller Module(CM xxHz zz yyPort)#MM<pp ss rr> BE Expander Port#nn Warning | SS : Parts subtype |
SMART notice from Disk | Warning | J 80SSEEEE Disk Drive(HDD-xxxGB-yyKrpm) DE#DD/Slot#nn<pp ss rr cc> SMART | SS : Parts subtype |
Disk preventative separation SMART | Warning | J 80SSEEEE Disk Drive(HDD-xxxGB-yyKrpm) DE#DD/Slot#nn<pp ss rr cc> Warning | SS : Parts subtype |
SMART notice from Disk | Warning | J 81SSEEEE Disk Drive(HDD-xxxGB-yyKrpm) DE#DD/Slot#nn<pp ss rr cc> SMART | SS : Parts subtype |
Disk preventative separation SMART | Warning | J 81SSEEEE Disk Drive(HDD-xxxGB-yyKrpm) DE#DD/Slot#nn<pp ss rr cc> Warning | SS : Parts subtype |
SATA Disk notice from Disk | Warning | J 82SSEEEE Disk Drive(HDD-xxxGB-SATA) DE#DD/Slot#nn<pp ss rr cc> SMART | SS : Parts subtype |
SATA Disk preventative separation SMART | Warning | J 82SSEEEE Disk Drive(HDD-xxxGB-SATA) DE#DD/Slot#nn<pp ss rr cc> Warning | SS : Parts subtype |
SMAR notice from SATA Disk | Warning | J 83SSEEEE Disk Drive(HDD-xxxGB-SATA) DE#DD/Slot#nn<pp ss rr cc> SMART | SS : Parts subtype |
SATA Disk preventative separation SMART | Warning | J 83SSEEEE Disk Drive(HDD-xxxGB-SATA) DE#DD/Slot#nn<pp ss rr cc> Warning | SS : Parts subtype |
EXP Alarm | Warning | J 9002EEEE Expander(EXP) DE#DD/Group#nn<pp ss rr> Warning | SS : Parts subtype |
EXP Port | Warning | J 9002EEEE Expander(EXP) DE#DD/Group#N/Port#nn<pp ss rr> Warning | SS : Parts subtype |
Event notification (M messages)
Target | Level | Event display | Remarks |
---|---|---|---|
Write Bad Data | Error | M E0050xxx WRITE BAD DATA | xxx : RLU No. |
PINNED Data | Error | M E10300MM PINNED DATA | MM : CM module ID where PINNED occurred |
NRDY (Factor 01) | Error | M E2070001 NOT READY(01:Configration Error) | |
NRDY (Factor 02) | Error | M E2070002 NOT READY(02:CM F/W Version Error) | |
NRDY (Factor 03) | Error | M E2070003 NOT READY(03:NVRAM Parity Error) | |
NRDY (Factor 04) | Error | M E2070004 NOT READY(04:Restore Fail) | |
NRDY (Factor 05) | Error | M E2070005 NOT READY(05:RSP/SVC Degrade) | |
NRDY (Factor 06) | Error | M E2070006 NOT READY(06:Basic Set Online(Pre) Error) | |
NRDY (Factor 07) | Error | M E2070007 NOT READY(07:Basic Set Online(Recovery) Error) | |
NRDY (Factor 08) | Error | M E2070008 NOT READY(08:Basic Set Online(Normal) Error) | |
NRDY (Factor 09) | Error | M E2070009 NOT READY(09:Maintenance Set Online Error) | |
NRDY (Factor 10) | Error | M E207000A NOT READY(10:Basic Restore Error) | |
NRDY (Factor 11) | Error | M E207000B NOT READY(11:Power Off/Fail Incomplete) | |
NRDY (Factor 12) | Error | M E207000C NOT READY(12:Backup Fail) | |
NRDY (Factor 13) | Error | M E207000D NOT READY(13:Multi CM Down) | |
NRDY (Factor 14) | Error | M E207000E NOT READY(14:Machine Down Recovery End) | |
NRDY (Factor 15) | Error | M E207000F NOT READY(15:Machine Down Recovery Failed) | |
NRDY (Factor 16) | Error | M E2070010 NOT READY(16:DE Build Error) | |
NRDY (Factor 17) | Error | M E2070011 NOT READY(17:CM Memory Shortage) | |
NRDY (Factor 18) | Error | M E2070012 NOT READY(18:PBC Combination Error) | |
NRDY (Factor 19) | Error | M E2070013 NOT READY(19:RT Type Error) | |
NRDY (Factor 21) | Error | M E2070015 NOT READY(21:Configuration Data restored from System Disk) | |
NRDY (Factor 22) | Error | M E2070016 NOT READY(22:No Version) | |
FC loop recovery success | Error | M E406C0DD FC Loop Recovery Completed | DD : Young number DE No. |
FC loop recovery failure | Error | M E406F0DD FC Loop Recovery Failed | DD : Young number DE No. |
End of rebuild to HS | Error | M 21810xxx RAID Group#0xxx REBUILD to HS (Recovered end) | xxx : RLU No. |
End of rebuild to DV | Error | M 21810xxx RAID Group#0xxx REBUILD to DV (Recovered end) | xxx : RLU No. |
Disconnected intra-cabinet path | Error | M 38040C0732xxyy Remote Copy Path (MID#xx PORT#yy) Not Available | xx : MID |
Recovery notification
Target | Level | Event display | Remarks |
---|---|---|---|
CM BE Expander Warning recovery | Information | R 06SSMM00 Controller Module(CM xxHz zz yyPort)#MM<pp ss rr> BE Expander Normal | SS : Parts subtype |
EXP Warning recovery | Information | R 9002EEEE Expander(EXP) DE#DD/Group#nn<pp ss rr> Normal | EEEE : Position information |
PSU Alarm recovery (AC-Fail clear) | Information | R D200DD0N Power Supply(PSU) DE#DD/Slot#nn<pp ss rr> Normal | DD : DE-ID |
DE exhaust temperature alarm recovery | Information | R DA0tDD00 DE OUT TEMP Normal | DD : DE-ID |
DE intake air temperature alarm recovery | Information | R DB0tDD00 DE IN TEMP Normal | DD : DE-ID |