ETERNUS SF Express V15.0/ Storage Cruiser V15.0 Event Guide

2.2.4 McDATA Fibre Channel Switch Events

Failure event

Level

Event display

Troubleshooting

The status of the Fibre Channel port has changed to online.

Information

The status of the port has changed to Online Port No.%NUMBER%

None.

The status of the Fibre Channel port has changed to offline.

Information

The status of the port has changed to Offline Port No.%NUMBER%

Check whether the cable was disconnected and then reconnected. If this operation was not performed, check the SFP, cable, and the connection destination switch.

The status of the Fibre Channel port has changed to testing.

Information

The status of the port has changed to Testing Port No.%NUMBER%

If the Testing operation was not performed, contact Support.

The status of the Fibre Channel port has changed to error.

Error

The status of the port has changed to Faulty Port No.%NUMBER%

Check whether the cable was disconnected and then reconnected. If this operation was not performed, check the SFP, cable, and the connection destination switch.

The status of the FRU has changed to unknown.

Warning

The status of the unit has changed to Unknown FRU(%FRU NAME%) %NUMBER%

*1

Replace modules that are deemed to be defective.

The status of the FRU has changed to normal.

Information

The status of the unit has changed to Active FRU(%FRU NAME%) %NUMBER%

*1

None.

The status of the FRU has changed to backup.

Information

The status of the unit has changed to Backup FRU(%FRU NAME%) %NUMBER%

*1

None.

The status of the FRU has changed to update/busy.

Information

The status of the unit has changed to Update-busy FRU(%FRU NAME%) %NUMBER%
*1

None.

The status of the FRU has changed to error.

Error

The status of the unit has changed to failed FRU(%FRU NAME%) %NUMBER%

*1

Replace modules that are deemed to be defective.

A connection has been made to a device for which connection is not allowed.

Warning

The switch detects that a port binding violation occurs.

Check the SANtegrity settings.

The status of the FRU has changed to unknown.

Warning

The FRU(%FRU NAME%) %NUMBER% is removed or changes to an unknown status.

*1

Replace modules that are deemed to be defective.

The status of the FRU has changed to normal.

Information

The FRU(%FRU NAME%) %NUMBER% transitions to an active status.

*1

None.

The status of the FRU has changed to backup.

Information

The FRU(%FRU NAME%) %NUMBER% transitions to a backup status.

*1

None.

The status of the FRU has changed to update/busy.

Information

The FRU(%FRU NAME%) %NUMBER% transitions to an update/busy status.

*1

None.

The status of the FRU has changed to error.

Error

The FRU(%FRU NAME%) %NUMBER% transitions to a failed status.

*1

Replace modules that are deemed to be defective.

The Fibre Channel port Link Bit error rate has exceeded the threshold.

Warning

Bit error rate for a link exceeded an allowed threshold in Port No.%NUMBER%

Check the SFP, cable, and the connection destination switch.

The Fibre Channel port connection was lost.

Warning

Lost of signal or sync in port %NUMBER%

Check the SFP, cable, and the connection destination switch.

An abnormal sequence was received.

Error

Not operational primitive sequence was received in Port No.%NUMBER%

Check the SFP, cable, and the connection destination switch.

The sequence timed out.

Error

Primitive sequence timeout occurred in Port No.%NUMBER%

Check the SFP, cable, and the connection destination switch.

An invalid sequence was detected.

Error

Invalid primitive sequence was detected in Port No.%NUMBER%

Check the SFP, cable, and the connection destination switch.

A new connection was detected.

Information

The firmware detects that a new connection has been established on a Port No.%NUMBER%

None.

*1: The %FRU NAME% may contain any of the following strings:
BKPLNE, CTP, SBR, Center FAN, FAN, POWER, GLSL, GSML, GXXL, FPM, UPM, GLSR, GSMR, GXXR, FINT1, XPM