Failure event | Level | Event display | Troubleshooting |
---|---|---|---|
The status of the Fibre Channel port has changed to online. | Information | The status of the port has changed to Online Port No.%NUMBER% | None. |
The status of the Fibre Channel port has changed to offline. | Information | The status of the port has changed to Offline Port No.%NUMBER% | Check whether the cable was disconnected and then reconnected. If this operation was not performed, check the SFP, cable, and the connection destination switch. |
The status of the Fibre Channel port has changed to testing. | Information | The status of the port has changed to Testing Port No.%NUMBER% | If the Testing operation was not performed, contact Support. |
The status of the Fibre Channel port has changed to error. | Error | The status of the port has changed to Faulty Port No.%NUMBER% | Check whether the cable was disconnected and then reconnected. If this operation was not performed, check the SFP, cable, and the connection destination switch. |
The status of the FRU has changed to unknown. | Warning | The status of the unit has changed to Unknown FRU(%FRU NAME%) %NUMBER% *1 | Replace modules that are deemed to be defective. |
The status of the FRU has changed to normal. | Information | The status of the unit has changed to Active FRU(%FRU NAME%) %NUMBER% *1 | None. |
The status of the FRU has changed to backup. | Information | The status of the unit has changed to Backup FRU(%FRU NAME%) %NUMBER% *1 | None. |
The status of the FRU has changed to update/busy. | Information | The status of the unit has changed to Update-busy FRU(%FRU NAME%) %NUMBER% | None. |
The status of the FRU has changed to error. | Error | The status of the unit has changed to failed FRU(%FRU NAME%) %NUMBER% *1 | Replace modules that are deemed to be defective. |
A connection has been made to a device for which connection is not allowed. | Warning | The switch detects that a port binding violation occurs. | Check the SANtegrity settings. |
The status of the FRU has changed to unknown. | Warning | The FRU(%FRU NAME%) %NUMBER% is removed or changes to an unknown status. *1 | Replace modules that are deemed to be defective. |
The status of the FRU has changed to normal. | Information | The FRU(%FRU NAME%) %NUMBER% transitions to an active status. *1 | None. |
The status of the FRU has changed to backup. | Information | The FRU(%FRU NAME%) %NUMBER% transitions to a backup status. *1 | None. |
The status of the FRU has changed to update/busy. | Information | The FRU(%FRU NAME%) %NUMBER% transitions to an update/busy status. *1 | None. |
The status of the FRU has changed to error. | Error | The FRU(%FRU NAME%) %NUMBER% transitions to a failed status. *1 | Replace modules that are deemed to be defective. |
The Fibre Channel port Link Bit error rate has exceeded the threshold. | Warning | Bit error rate for a link exceeded an allowed threshold in Port No.%NUMBER% | Check the SFP, cable, and the connection destination switch. |
The Fibre Channel port connection was lost. | Warning | Lost of signal or sync in port %NUMBER% | Check the SFP, cable, and the connection destination switch. |
An abnormal sequence was received. | Error | Not operational primitive sequence was received in Port No.%NUMBER% | Check the SFP, cable, and the connection destination switch. |
The sequence timed out. | Error | Primitive sequence timeout occurred in Port No.%NUMBER% | Check the SFP, cable, and the connection destination switch. |
An invalid sequence was detected. | Error | Invalid primitive sequence was detected in Port No.%NUMBER% | Check the SFP, cable, and the connection destination switch. |
A new connection was detected. | Information | The firmware detects that a new connection has been established on a Port No.%NUMBER% | None. |
*1: The %FRU NAME% may contain any of the following strings:
BKPLNE, CTP, SBR, Center FAN, FAN, POWER, GLSL, GSML, GXXL, FPM, UPM, GLSR, GSMR, GXXR, FINT1, XPM
Also see "2.5.1 Fibre Alliance MIB Support Device Events".