From the Fibre Channel switch whose firmware version is 2.2 or more, the trap with the asterisk ("*") isn't notified but is notified as an event trap.
Failure event | Level | Event display | |
---|---|---|---|
System failure | Error | Central Memory FAULT | |
System failure | Error | Embedded Port FAULT | |
FC port failure | Error | FC Port No.number FAULT | |
FC port online | Information | FC Port No.number Online | |
FC port offline | Information | FC Port No.number Offline | |
* | Power supply failure | Error | Power Supply #number FAULT |
* | Power-off | Error | Power Supply #number FAULT |
* | Power loss | Warning | Power Supply #number Absent |
* | Fan failure | Error | Fan #number FAULT |
* | Fan rotational speed decrease error | Error | Fan #number Below Minimal Threshold |
* | Fan loss | Warning | Fan #number Absent |
* | Temperature sensor failure | Error | Temp #number FAULT |
* | Temperature decrease error | Error | Temp #number Below Minimal Threshold |
* | Temperature rise error | Error | Temp #number Above Maximum Threshold |
* | Temperature sensor loss | Warning | Temp #number Absent |
Trap event | Error, | The unit trap message is output without any change. |
Note
It may takes a time to display the event when FC Port failure, FC Ports online or FC Port offline.
Following SNMP traps are displayed in the event log when execute disconnect/connect FC cable in a short time.
When the cable is disconnected : [Link Down Trap]
When the cable is connected : [Link Up Trap]
The port where the trouble occurs cannot be specified from the event log, also the event linkage function doesn't operate. Please login to the Fibre Channel switch to specify the Port where the trouble occurs, and confirm the state of the VE port and the GbE port.
* Also following event logs are displayed with above event log.
When the cable is disconnected : [FC Port No.214 Offline]