Top
ETERNUS SF Express V15.0/ Storage Cruiser V15.0 Event Guide

2.2.1 SN200 (Brocade) Events

From the Fibre Channel switch whose firmware version is 2.2 or more, the trap with the asterisk ("*") isn't notified but is notified as an event trap.

Failure event

Level

Event display

System failure

Error

Central Memory FAULT

System failure

Error

Embedded Port FAULT

FC port failure

Error

FC Port No.number FAULT

FC port online

Information

FC Port No.number Online

FC port offline

Information

FC Port No.number Offline

*

Power supply failure

Error

Power Supply #number FAULT

*

Power-off

Error

Power Supply #number FAULT

*

Power loss

Warning

Power Supply #number Absent

*

Fan failure

Error

Fan #number FAULT

*

Fan rotational speed decrease error

Error

Fan #number Below Minimal Threshold

*

Fan loss

Warning

Fan #number Absent

*

Temperature sensor failure

Error

Temp #number FAULT

*

Temperature decrease error

Error

Temp #number Below Minimal Threshold

*

Temperature rise error

Error

Temp #number Above Maximum Threshold

*

Temperature sensor loss

Warning

Temp #number Absent

Trap event

Error,
Warning,
Information

The unit trap message is output without any change.

Note

  • It may takes a time to display the event when FC Port failure, FC Ports online or FC Port offline.

    Following SNMP traps are displayed in the event log when execute disconnect/connect FC cable in a short time.

    • When the cable is disconnected : [Link Down Trap]

    • When the cable is connected : [Link Up Trap]

    The port where the trouble occurs cannot be specified from the event log, also the event linkage function doesn't operate. Please login to the Fibre Channel switch to specify the Port where the trouble occurs, and confirm the state of the VE port and the GbE port.

    * Also following event logs are displayed with above event log.

    • When the cable is disconnected : [FC Port No.214 Offline]

    • When the cable is connected : [FC Port No.214 Online]