ETERNUS SF Express V15.0/ Storage Cruiser V15.0 Event Guide

1.2.1 Common event

Point

The device name is not displayed in the event that there is "*" in the leftmost column of the following table.
Please sort by date and refer.

Event log display example

Explanation

Measure

Add + device-model-name

A device has been added.

Delete + device-model-name/parts-name

A device has been deleted.

Set SNMP Trap transmission address 12.34.56.78

The trap transmission address of the device was set to 12.34.56.78.

Delete SNMP Trap transmission address 12.34.56.78

The trap transmission address 12.34.56.78 was deleted from the device.

Change SNMP Trap transmission address

The trap transmission address of the device has been changed.

*

Connect Access Path

The access path has been connected.

*

Delete Access Path

The access path has been deleted.

*

Re-set Access Path for + FC port name

The access path has been inherited.

Delete Switch Zone

The zoning information has been deleted.

*

Failed

An error was found during the user operation.

Respond in accordance with the Operation History and the message ID during operation.

*

Same WWPN already exists.(WWPN=222800000EA60011)

WWPN (222800000EA60011) is duplicated.

Check the setting if the FC device allows change of the WWPN according to user settings.

Invalid WWPN is detected in device model name (WWPN = WWPN information)

An incorrect WWPN was detected.

Check the setting if the FC device allows change of the WWPN according to user settings.

*

Same iSCSI Name and same IP Address already exists.
(iSCSI Port= iqn.1991-05.com.microsoft:bx600s3-wsfcb.fpro(192.168.1.1))

There is a duplicate value in the iSCSI Port iSCSI name and IP address settings.

Check the iSCSI name and IP address settings, and edit them so that each setting has a unique value.

Invalid iSCSI Name is detected in iSCSI Port (iSCSI Port= iSCSI Port information)

An invalid iSCSI name was detected.

Check the iSCSI name setting.

SNMP Trap was received. But the source IP address(12.34.56.78) of SNMP Trap is duplicately used by some devices in DB of Manager.

A SNMP trap was received, but the source IP address of the SNMP trap is used by multiple management target devices.

Make sure that the IP address and other information entered for incorporating the device manually is correct.

Unsupported Firmware Version v12.34.56

A device with firmware v12.34.56, which is not supported by Storage Cruiser, was detected.

Firmware not supported Storage Cruiser is used for the target device.
Contact your Fujitsu engineer (CE or SE) because patches need to be applied to Storage Cruiser.

This message is displayed at the time of an operation such as [Reload Conf.].
See also "FIRMWARE_VERSION_CHECK" of "sanma.conf Parameter" in the "ETERNUS SF Storage Cruiser Operation Guide".