Top
PRIMECLUSTER Wizard for NetWorker 4.2 Configuration and AdministrationGuide

6.4.2 hvnwdisable/hvnwenable messages

Message is displayed by the format: “command name : level of message : message“. “hvnwdisable” or “hvnwenable” is displayed as “command name“. The description of format below omits command name.

ERROR: Internal error! (details)

[Content]

An internal error occurred.

[Corrective action]

Contact your system administrator.

ERROR: Failed to disable/enable resource monitoring - resource_name

[Content]

Cannot disable or enable monitoring.

[Corrective action]

Contact your system administrator.

ERROR: hvgdconfig does not exist!

[Content]

hvgdconfig file does not exist.

[Corrective action]

Check if building a userApplication (cluster application) has been completed.

ERROR: Obtaining local SysNode Name failed!

[Content]

Cannot get a local SysNode name.

[Corrective action]

Check if CF (Cluster Foundation) has been configured and is "UP" state.

ERROR: Obtaining RMS configuration Name failed!

[Content]

The RMS configuration name is note able to obtain.

[Corrective action]

Confirm the setting of userApplication (cluster application) is completed.

ERROR: Result of hvw is invalid!

[Content]

RMS hvw (1M) command is failed.

[Corrective action]

Confirm the setting of userApplication (cluster application) is completed.

ERROR: Failed to disable/enable resource monitoring! (details)

[Content]

Cannot disable or enable monitoring because of details.

[Corrective action]

Check if PRIMECLUSTER installation, cluster setup and building a cluster application (userApplication) have been completed.

ERROR: No Wizard for NetWorker resources belong to specified userApplication! - userApplication_name

[Content]

There is no PRIMECLUSTER Wizard for NetWorker resource in the specified userApplication userApplication_name.

[Corrective action]

Retry with a correct userApplication name.

ERROR: No Wizard for NetWorker resources are in the current RMS configuration!

[Content]

There is no PRIMECLUSTER Wizard for NetWorker resource in the current RMS configuration.

[Corrective action]

Check if building a userApplication (cluster application) has been completed or NetWorker resources are included in the userApplication.

ERROR: No Wizard for NetWorker resources exist on this node! - SysNode_name

[Content]

There is no PRIMECLUSTER Wizard for NetWorker resource on a local node SysNode_name.

[Corrective action]

Check if building a userApplication (cluster application) has been completed or NetWorker resources are included in the userApplication.

ERROR: Invalid userApplication or Resource!

[Content]

The specified userApplication name or resource name is invalid.

[Corrective action]

Retry with a correct userApplication name and resource name.

ERROR: The specified resource does not exist on SysNode_name! - resource_name

[Content]

The specified resource does not exist on a local node SysNode_name.

[Corrective action]

Retry with a correct resource name or retry on a correct node.