Top
ServerView Resource Coordinator VE V2.2.2 Setup Guide

3.5 Configuring the Server Environment

This section describes how to configure servers and chassis for Resource Coordinator VE.


Chassis Settings (for Blade Servers)

Refer to the management blade manual to apply the settings chosen in "3.1.1 Chassis Settings (For blade server environments)" to the management blade.
Note that the SNMP community must be set to Write (read and write) access.

Refer to the management blade manual to set the following SNMP agent settings.

Note

When powering off a chassis together with its enclosed server blades, servers are shut down using the graceful shutdown option of the management blade. To enable this feature, all servers within the chassis should have a ServerView Agent installed.


Chassis Settings (PRIMERGY Partition Models)

Refer to the management board manual to apply the settings chosen in "3.1.4 Chassis Settings (Settings for PRIMERGY Partition Models)" to the management board.
Note that the SNMP community must be set to Write (read and write) access.

Enable the following function referring the instructions given in the management board's manual.

Mode Switch Settings for the Operator Panel (SPARC Enterprise M Series Servers)

When managing SPARC Enterprise M series servers using Resource Coordinator VE, set the mode switch of operator panel to "Locked" in the OpenBoot configuration to automatically start up the OS when powering on SPARC Enterprise M series servers.


Chassis Settings (SPARC Enterprise M4000/M5000/M8000/M9000 servers)

Refer to the remote management controller manual to apply the settings chosen in "3.1.5 Chassis Settings (SPARC Enterprise M4000/M5000/M8000/M9000 servers)" to the management blade.
Note that the SNMP community must be set to Write (read and write) access.

Refer to the instructions given in the XSCF manual and enable the following functions.

Remote Management Controller Settings (for Non-Blade Servers)

Refer to the remote management controller manual to configure the following on the IPMI controller.

For SPARC Enterprise M3000 servers, refer to the XSCF manual and enable the following services.

For SPARC Enterprise T series servers, refer to the ILOM manual and enable the following services.

Note

When assigning multiple IP addresses to multiple network interfaces on a XSCF module, make sure that the IP address used by Resource Coordinator VE is assigned to the first of those network interfaces.


BIOS Settings for Managed Servers

The following BIOS configurations must be modified.

System BIOS

This is the system BIOS for a managed server.
Enable or disable the internal SCSI BIOS and FC-HBA BIOS as appropriate, and set up the appropriate boot order.

Note

  • The BIOS settings of server blades include an option to automatically start up servers when their enclosing chassis is powered on. For details, refer to the server blade manual.

  • For PRIMERGY BX900/BX400, when an LND-PG203 is mounted as the LAN expansion card of the server blade, do not set the NIC of the LAN expansion card as "disable" in the server blade's BIOS settings.
    The connections between server blades and LAN switch blades are not shown correctly, when "disable" is set.
    The following functions do not operate correctly.

    • Changing and setting the VLAN for LAN switch blades (internal and external ports)

    • Server switchover (changing network settings while a server is switched over)

Internal SCSI BIOS

These are the BIOS settings for the internal SCSI disk(s) of a managed server.
Enable or disable booting from internal disks as appropriate.

FC-HBA BIOS

This is a BIOS setting that relates to FC-HBAs that have been installed as an expansion card in the blade server.
Enable or disable SAN boot as well as the connection of a SAN storage environment by means of a Fibre Channel switch.

Configure the following settings depending on the operating environment.

OS Settings for Managed Servers

When using the following functions, configure the OS to respond to ping commands.

Settings for Server Virtualization Software

Server virtualization software must be configured appropriately for Resource Coordinator VE.

Refer to "A.2 Configuration Requirements" for details on the required server virtualization software settings.


OBP (Open Boot Prom) Settings (SPARC Enterprise)

When managing SPARC Enterprise servers from Resource Coordinator VE, set the "autoboot?" option to "true" in the OBP configuration. Otherwise, the operating system will not automatically start up when powering on SPARC Enterprise servers.

For details, refer to "SPARC Enterprise - ETERNUS SAN Boot Environment Build Guide" of the Fibre Channel card driver manual.


Settings for ServerView Operations Manager (VMware ESXi)

When managing VMware ESXi using Resource Coordinator VE, register the target VMware ESXi with ServerView Operations Manager.

For details, refer to the ServerView Operations Manager manual.