Top
Cloud Infrastructure Management SoftwareV1.2.0 User's Guide

I.2.1 Setting up the Devices for which Eco Information is Collected

To collect eco information, SNMP traps must be set up for the target device. Specifically, set up the following items:

The procedure for setting up SNMP traps varies depending on the target device type. Refer to the manuals for each device for details.

This section explains the procedure for setting up SNMP traps, using the PRIMERGY BX900 as an example.

  1. Open the Web User Interface window for the ServerView management blade for the target device.

    Use a Web browser to access the Web User Interface for the ServerView management blade.

    • For HTTP

      http://[<IP address of the ServerView management blade>]:[<Port number (default: 80)>]

    • For HTTPS

      https://[<IP address of the ServerView management blade]:[Port number (default: 443)>]

  2. A window for entering the password will be displayed, so enter the user name and password that have been specified for the ServerView management blade.

  3. The start page for the ServerView management blade will be displayed. Select the [Settings] - [System Unit] and then SNMP from the menu on the left.

  4. Select SNMP Setting in the tab on the right.

  5. Check that the Enable SNMP checkbox has been selected in the Enable SNMP settings. If this checkbox has not been selected, select it and click the <Apply>.

  6. Check that there is a "public" entry in the SNMP community settings. If not, use Add community below the SNMP community and specify "public" for Community and "read only" for the user privileges. Then click the <Apply>.

  7. Add the IP address of the Admin Server to the SNMP trap destination settings. Use Event type of New trap destination below that to set Destination address/server name to the IP address of the Admin Server, Community to "public" and Type of Event to "AllEvent", and then click the <Apply>.

  8. Confirm that the IP address of the Admin Server has been added to the SNMP trap destination settings as shown in the window

  9. Close the window by signing out from the Web User Interface for the ServerView management blade.