This appendix describes the error code and detailed error messages output by the ETERNUS disk storage system, which were inserted into the messages.
If an error message not shown in this table appears, a hardware failure may have occurred. In such an event, contact your Fujitsu customer engineer (CE).
Error | Error message | Explanation | Corrective action |
---|---|---|---|
2 | invalid logical volume name. | The specified copy source or destination device is not found. | Check that the slice information exists on the copy source or destination device. |
3 | invalid extent number. | An internal conflict occurred. | Ask a Fujitsu systems engineer (SE) to collect the data necessary for troubleshooting. (NOTE) |
4 | invalid source BoxID. | An internal conflict occurred. | |
5 | invalid destination BoxID. | An internal conflict occurred. | |
6 | invalid source OLU. | The specified copy source or destination device is not found. | Check the partition information for the copy source device. |
7 | invalid destination OLU. | The specified copy source or destination device is not found. | Check the partition information for the copy destination device. |
8 | invalid extent. | The copy source or destination device does not exist. | Check the slice information on the copy source or destination device. |
11 | invalid source extent size. | An internal conflict occurred. | Ask a Fujitsu systems engineer (SE) to collect the data necessary for troubleshooting. (NOTE) |
12 | invalid copy interval. | The specified copy interval is invalid. | |
17 | Not support. | The specified copy function is not supported. | Contact a Fujitsu customer engineer (CE). |
22 | not STX. | The copy source or destination device does not exist. | Check the slice information on the copy source or destination device. |
24 | hardware error requiring CE-CALL. | A SCSI error (CheckCondition) was detected. | Check the device connection status and then retry. |
25 | SCSI condition met. | A SCSI error (Condition met) was detected. | |
26 | SCSI command busy. | One of the following events occurred.
| Take the applicable action as follows:
For other cases, contact a Fujitsu customer engineer (CE). |
27 | SCSI command conflict. | A SCSI error (a command conflict) was detected. | Check the device connection status and then retry. |
28 | SCSI queue full. | A SCSI error (queue full) was detected. | |
29 | unexpected SCSI error. | A SCSI error (abnormal status) was detected. | |
35 | invalid MPHD environment. | An MPHD path name was specified for the logical volume name when MPHD was not installed. | Check whether MPHD is installed. |
36 | memory allocation error. | Dynamic memory allocation failed. | Allocate sufficient memory or a swap area, or terminate any other programs that are being executed. |
37 | invalid option flag. | An internal conflict occurred. | Ask a Fujitsu systems engineer (SE) to collect the data necessary for troubleshooting. (NOTE) |
38 | invalid SynfinityDISK environment. | SynfinityDISK resource is not supported. | Specify a resource other than SynfinityDISK. |
39 | out of sequence. | One of the following occurred:
| Take one of the following actions:
If this fails to solve the problem, contact a Fujitsu systems engineer (SE). |
48 | invalid OLU. | The specified copy source or destination device is invalid because:
| Check the device that is the copy source or the device partition information of the copy destination, and retry the function. |
56 | invalid GDHD environment. | A GDHD path name was specified for the logical volume name when GDHD was not installed. | Check whether GDHD is installed. |
57 | invalid BoxID. | The specified remote cabinet identifier is invalid. | Check the connection conditions between cabinets, and retry. |
58 | invalid role. | The specified remote copy direction is invalid. | |
59 | setup is inadequate | The copy settings are not sufficient for normal operation. One of the following events occurred:
| Contact a Fujitsu customer engineer (CE) and systems engineer (SE). |
60 | bit map resolution disagree. | The bitmap resolution between cabinets is inconsistent. | |
61 | communication interrupted. | An error occurred in communication between cases. | Check the connection state between the cabinets, and retry processing. |
62 | another partner is not supported. | The version of firmware of one cabinet is not supported. | Contact a Fujitsu customer engineer (CE). |
63 | the session mode was not changed. | An attempt to switch the session mode has failed. (But the original status remains as is.) | Check the connection status between cabinets and then retry. |
64 | the session mode crosses. | An attempt to switch the session mode has failed. (Information between cabinets is inconsistent.) | |
65 | the operation of SnapOPC was failed. | One of the following has occurred:
| Take one of the following actions:
If this fails to solve the problem, contact a Fujitsu customer engineer (CE) and systems engineer (SE). |
66 | the operation of REC buffer was failed. | An attempt to either display information or change the settings for the REC transfer buffer has failed. | Check the settings status of the REC transfer buffer and then rerun the command. |
67 | the operation of concurrent suspend was failed. | A concurrent suspension operation has failed. (But the original status remains as is.) | Check the status of all sessions, and then rerun the command. For HP-UX and AIX editions, check that the copy destination volume is the same size or larger than the copy source volume. |
68 | invalid Snap Data volume. | A Snap Data volume specification error has been detected.
A volume other than a Snap Data volume was specified for Snap Data volume initialization. | Check the partition information for the copy source or copy destination device, and then rerun the command. |
69 | not support in GR-API. | The specified volume is not supported. | Check that the size of the specified volume is less than 2TB. |
70 | disk drive motor off. | The disk drive is in the stopped state due to the Eco-mode. | Rerun the command when the disk drive is being activated. |
Refer to the following manual, collect the data necessary for troubleshooting.
"Collecting maintenance information" in the "ETERNUS SF AdvancedCopy Manager Operator's Guide"