Registry reading failed.
Explanation
The registry could not be read.
System action
The system interrupts processing.
System administrator response
Check whether AdvancedCopy Manager is installed correctly.
Registry information file reading failed.
Explanation
The registry information file could not be read.
System action
The system interrupts processing.
System administrator response
Check whether AdvancedCopy Manager is installed normally.
DB environment setup failed.
Explanation
The DB environment could not be set up.
System action
The system interrupts processing.
System administrator response
Perform error processing of the DB setup command and then retry. Note that this message is also output if Cancel is selected by the DB setup command.
Registry writing failed.
Explanation
Data could not be written to the registry.
System action
The system interrupts processing.
System administrator response
Refer to the following manual and collect the information required for troubleshooting, and then contact a Fujitsu systems engineer.
"Collecting maintenance information" in the "ETERNUS SF AdvancedCopy Manager Operator's Guide"
A handle used to identify the service control manager database could not be obtained.
Explanation
A handle used to identify the service control manager database could not be obtained.
System action
The system interrupts processing.
System administrator response
Refer to "Starting and Stopping a Service" in the "ETERNUS SF AdvancedCopy Manager Operator's Guide", and start the AdvancedCopy Manager service.
Service activation failed. Service name = [SERVICE]
Explanation
The service indicated in SERVICE parameter could not be started.
Parameters
SERVICE : Service name
System action
The system interrupts processing.
System administrator response
Refer to "Starting and Stopping a Service" in the "ETERNUS SF AdvancedCopy Manager Operator's Guide", and start the service indicated in SERVICE parameter.
Startup account setting failed. Please confirm the account name and the password and input it again.
Explanation
The startup account could not be set. Authentication was probably unsuccessful.
System action
The system interrupts processing.
System administrator response
Check the account name and password, and then retry.
If this fails to solve the problem, contact a Fujitsu systems engineer.
A port number could not be set.
Explanation
The port number could not be set.
System action
The system interrupts processing.
System administrator response
Check access permissions for the "Windows install directory"\system32\drivers\etc\services file and then retry.
If this fails to solve the problem, contact a Fujitsu systems engineer.
The service could not be registered. Service Name: [SERVICE]
Explanation
The service indicated in SERVICE parameter could not be registered.
Parameters
SERVICE : Name of the service that could not be registered
System action
The system interrupts processing.
System administrator response
Ensure that no existing service has the same name and then retry.
If this fails to solve the problem, contact a Fujitsu systems engineer.
SymfoWARE could not be installed.
Explanation
SymfoWARE could not be installed.
System action
The system interrupts processing.
System administrator response
An old version of SymfoWARE may have been installed. If SymfoWARE is already installed, check its version.
If this fails to solve the problem, contact a Fujitsu systems engineer.
Symfoware Client could not be installed.
Explanation
Installation of Symfoware Client failed.
System action
The system interrupts processing.
System administrator response
Contact a Fujitsu system engineer.
Failed to set up the ACCLI.
Explanation
Set up of the ACCLI function failed.
System action
The system interrupts processing.
System administrator response
Contact a Fujitsu system engineer.
Symfoware Server in a different version-level has already been installed.
Explanation
A different version-level of Symfoware Server has already been installed.
System action
The system interrupts processing.
System administrator response
It is possible that a Symfoware Server that is not handled is installed. If the Symfoware Server is already installed, take the following action:
Install a Symfoware client with the same version-level as the installed Symfoware Server, and then re-install the manager.
Save the data of the current Symfoware Server, then uninstall Symfoware Server, and install AdvancedCopy Manager.