The following hardware conditions must be met when using Resource Coordinator VE:
For supported models, refer to the ServerView Resource Coordinator VE home page.
Software | Hardware | Remarks |
---|---|---|
Manager | PRIMERGY RX series servers | The CPU must be a multi-core CPU. |
PRIMERGY Partition Model | - | |
Agent | PRIMERGY BX620 S4 | When using servers other than the PRIMERGY BX series, it is necessary to mount an IPMI-compatible (*1) server management unit (*2). |
PRIMERGY Partition Model | - | |
SPARC Enterprise M series | To use power consumption monitoring, the XCP version should be after version 1090. | |
- | PRIMERGY SX650 | Registering a PRIMERGY BX series chassis displays it automatically. |
HBA address rename setup service | Personal computers | - |
*1: Support IPMI2.0.
*2: This usually indicates a BMC (Baseboard Management Controller)
*3: Supported after application of necessary patches.
.
Note
The functions that agents can use differ depending on the hardware being used.
Function | PRIMERGY series | SPARC Enterprise | Other PC servers | |||
---|---|---|---|---|---|---|
Blade Models | Rack-Mount/Tower Models | Partition Models | ||||
Status monitoring | Yes | Yes | Yes | Yes | Yes (*1) | |
Power operations | Yes | Yes | Yes | Yes | Yes | |
Backup and Restore (*2) | Yes | Yes | Yes | No | Yes | |
Hardware maintenance | Yes | Yes (*3) | Yes (*3) | No | Yes (*3) | |
Maintenance LEDs | Yes | No | No | No | No | |
Open external management software | Yes | Yes | Yes | Yes | No | |
Server switchover | Backup and Restore | Yes | Yes | No | No | Yes |
HBA address rename (*4) | Yes | Yes | No | No | No | |
VIOM Coordination Function | Yes (*5) | No | No | No | No | |
Cloning (*2, *6) | Yes | Yes | Yes | No | Yes | |
HBA address rename (*4) | Yes | Yes | No | No | No | |
VIOM Coordination Function | Yes (*5) | No | No | No | No | |
VLAN Settings | Yes | No | No | No | No | |
Pre-configuration | Yes | Yes | Yes | Yes | Yes | |
Power consumption monitoring | Yes (*7) | Yes (*8) | No | Yes (*9) | No |
Yes: Use possible.
No: Use not possible.
*1: Server monitoring in coordination with server management software is not possible.
*2: When agents are operating on iSCSI disks, image operations are not possible for the following disk configurations.
Perform operation using a single iSCSI disk configuration.
iSCSI disk + internal disk
iSCSI disk + SAN disk
*3: Maintenance LEDs cannot be operated.
*4: When using HBA address rename, the mounted HBA must be compatible with HBA address rename.
*5: ServerView Virtual-IO Manager is necessary.
*6: Cloning of Linux agents operating on iSCSI disks is not possible.
*7: Only BX900 S1 chassis and BX920 S1 servers are supported.BX920 S2 and BX922 S2 servers are also supported after application of necessary patches.
*8: Only rack mount models (RX200/300/600) are supported.
*9: Only M3000 servers are supported.
The following hardware is required for admin clients:
Software | Hardware | Remarks |
---|---|---|
Client | Personal computers | - |