Top
ServerView Resource Coordinator VE Setup Guide

3.1.2 Settings for Rack Mount or Tower Servers

Resource Coordinator VE supports the following types of remote management controllers to manage servers.

Choose values for the following remote management controller settings according to the criteria listed below.

Admin IP address (IP address of the IPMI controller)

The IP address must be in the same subnet as the admin server.

User name

Name of the user account used to log in the remote management controller and gain control over the managed server.
A user account with at least administration privileges within the remote management controller must be specified.
The user name can contain up to 16 alphanumeric characters and symbols (ASCII characters 0x20 to 0x7e).
If a user account with a name of 17 or more characters has already been set up, either create a new user account or rename it with a name of up to 16 characters.

Password

Password used to log in the remote management controller with the above user name.
The user password can contain up to 16 alphanumeric characters and symbols (ASCII characters 0x20 to 0x7e).
If a user account with password of 17 or more characters has already been set up, either create a new user account or change the password with one of up to 16 characters.

SNMP trap destination

The destination for SNMP traps sent by the remote management controller should be set as the admin server's IP address.

For PRIMERGY servers, the server status can be monitored from external server management software (ServerView Agent). In that case, choose a value for the following setting.

SNMP community name

Name of the SNMP community used to communicate with the management software (ServerView Agent) on the managed server.
This community name can contain up to 32 alphanumeric characters, underscores ("_"), and hyphens ("-").

Note

Use the same SNMP community for each server when using server switchover and cloning functions.