When the device polling function of this software detects the state change of the device, display it in the event as follows.
Note
When the state change of device is detected by executing [Refresh] operation, the following events are not displayed. Confirm the state from a device icon.
Event | Level | Event display | Troubleshooting |
---|---|---|---|
When the state changes into error(red) | Error | Unit status changed: Error | Please confirm the state of the device. |
When the state has changed warning(yellow) | Warning | Unit status changed: Warning | Please confirm the state of the device. |
When the state has changed normal(green) | Information | Unit status changed: OK | None. |
When the State has changed unmonitored | Warning | Connection Timeout | Please confirm whether the LAN between Manager and the device is operating normally. Please confirm whether the state of each device is proper, processes for network communication such as SNMP are operating, and when the device contains the server node Agent then the Agent is operating normally. If the community name of a device that uses SNMP for communication is changed, set the "SNMP_COMMUNITY_NAME_FOR_IP" to the setting file by referring to "C.2 sanma.conf Parameter" in the ETERNUS SF Storage Cruiser User's Guide, and reflect the contents of the setting file on this software. |
When communication has been recovered | Information | Connection OK | None. |
When error occurs in the polling function | Error | [Polling] (Error event) | Take appropriate action for each event message as follows:
|
When communication is reestablished, the event displayed differs, depending on the polling function communication method.
Device status polling method
In accordance with the most recent status, the event displayed is either Unit status changed: OK, Unit status changed: Warning, or Unit status changed: Error.
Communication status polling method
The event displayed is Connection OK. Changes in device status are not detected.
See
For information about polling methods, refer to the "ETERNUS SF Storage Cruiser User's Guide", section "Function Outline" > "Device Polling".
See
For information about this event of ETERNUS VS900 model 200 virtualization switch, refer to the "ETERNUS SF Storage Cruiser User's Guide", section "Environment Configuration" > "Fibre Channel Switch" > "VS900 model 200 Virtualization switch" > "Points of concern".