Event traps are messages reported from a device. If you have any questions about the message contents, refer to the instruction manual for hardware to take corrective actions.
Failure event | Level | Event display |
---|---|---|
Module degradation | Error | ElementName(Item Id)degraded See the following table for the detailed module display. |
Timing of battery replacement | Error | ElementName(Item Id)expiration |
Panic reboot due to a CM hardware error | Warning | CM(Item ID) HARD ERROR PANIC REBOOT |
Frequency of collectable memory errors | Warning | MEMORY (Item ID) ERROR |
Frequency of collectable CM errors | Warning | CM(Item ID) CORRECTABLE ERROR |
Panic reboot due to a CPU, FROM, SCM hardware, or CA hardware error | Warning | ElementName(Item ID) ERROR PANIC REBOOT |
Panic reboot or DA one-side port blocking due to a DA hardware failure | Warning | DA(Item ID) ERROR |
I2C bus error | Warning | IBUS(Item ID) BUS ERROR |
Disk error detection using the Disk SMART function | Warning | DISK (Item ID) SMART Warning |
CM Thermal Trip(CMCPT) | Warning | CM UNIT<CMCPT>(Item ID) Thermal Trip |
Voltage failure | Warning | ElementName(Item Id) Voltage Sensor Fault |
Temperature error | Error | ElementName(Item Id) Thermal Fatal Error |
Temperature warning | Warning | ElementName(Item Id) Thermal Warning |
Temperature warning | Warning | ElementName(Item Id) Temperature Warning |
Internal module communication error | Warning | ElementName(Item Id) Communication Error |
Internal module error(omen failure) | Warning | ElementName(Item Id) Error |
Internal module CHECK-1 | Warning | ElementName(Item Id) CHECK-1 |
Internal module warning | Warning | ElementName(Item Id) Warning |
Six months before a battery expires | Warning | ElementName(Item Id) Expiration Warning |
CM Warning(FAN ALARM #0) | Warning | CM(Item Id) Warning(FAN ALARM #0) |
CM Warning(FAN ALARM #1) | Warning | CM(Item Id) Warning(FAN ALARM #1) |
CM Warning(CR-6L BATTERY) | Warning | CM(Item Id) Warning(CR-6L BATTERY) |
CM Warning(FLASH MEMORY) | Warning | CM(Item Id) Warning(FLASH MEMORY) |
CM Warning(RTC Error) | Warning | CM(Item Id) Warning(RTC Error) |
CM Warning(RSP-CFD) | Warning | CM(Item Id) Warning(RSP-CFD) |
CM Warning(BIOS-CFD) | Warning | CM(Item Id) Warning(BIOS-CFD) |
CM Warning(CF-CFD) | Warning | CM(Item Id) Warning(CF-CFD) |
CM Warning(FAN ALARM #2) | Warning | CM(Item Id) Warning(FAN ALARM #2) |
CM Warning(FAN ALARM #3) | Warning | CM(Item Id) Warning(FAN ALARM #3) |
Write Bad Data occurrence | Error | Write Bad Data |
PIN Data occurrence | Error | PIN Data |
Multi Dead Recovery occurrence | Error | Multi Dead Recovery |
Disk move detection | Warning | Disk was removed to other slot |
Power ON retry | Error | Power ON Retry |
Machine Down Recovery occurrence | Error | Machine Down Recovery |
Not Ready occurrence | Error | Not Ready |
Memory table error | Error | Invalid Memory Table Address |
PBC Enclosure Service error | Error | PBC Enclosure Service Error |
FC Loop Recovery completed | Warning | FC Loop Recovery completed |
FC Loop Recovery failed | Error | FC Loop Recovery failed |
Rebuilding completed(Bad Data included) | Error | Rebuilding completed(Bad Data included) |
FC one-side Loop blocking | Error | FC Loop Error |
Remote copy path not available | Error | Remote copy path not available |
REC Automatic HALT occurrence | Error | REC Automatic HALT or ERROR occurred |
Module name | Event display Display format | GR710, | GR740, | ETERNUS4000(except M80 and M100), ETERNUS3000(except M50) | ETERNUS6000 |
---|---|---|---|---|---|
Controller enclosure | CE | ||||
Central module processor | CM | Yes | Yes | Yes | Yes |
PNB Chip(CMPNB) | CM UNIT<CMPNB> | Yes | |||
Compact flash memory | CM UNIT<CF> | Yes | |||
Compact flash memory | COMPACT FLASH | Yes | |||
Battery (CMBAT) | CM UNIT<CMBAT> | Yes | |||
RSP(CMRSP) | CM UNIT<CMRSP> | Yes | |||
RSP | RSP | Yes | |||
RTC(CMRTC) | CM UNIT<CMRTC> | Yes | |||
Advanced communication process (CA) | CA | Yes | Yes | Yes | Yes |
Advanced device process (DA) | DA | Yes | Yes | Yes | |
DA(CMDA) | CM UNIT<CMDA> | Yes | |||
RSP communication error (CMRCO) | CM COMM<CMRCO> | Yes | |||
CPU fan (CMCPF) | CM UNIT<CMCPF> | Yes | |||
Service control | SVC | Yes | Yes | Yes | |
Controller enclosure: Primary power supply unit | CE FE | Yes | |||
Controller enclosure: Secondary power supply unit (12V/5V) | CE BE(12V/5V) | Yes | |||
Controller enclosure: Secondary power supply unit (3.3V) | CE BE(3.3V) | Yes | |||
Controller enclosure: Fan | CE FAN | Yes | Yes | ||
Central module processor: Memory | MEMORY | Yes | Yes | Yes | Yes |
Central module processor: CPU | CM CPU | Yes | Yes | ||
CPU voltage failure (CMCVL) | CM UNIT<CMCVL> | Yes | |||
CPU temperature error (CMTMP) | CM UNIT<CMTMP> | Yes | |||
Internal temperature sensor error (CMTPS) | CM UNIT<CMTPS> | Yes | |||
Controller enclosure: Panel unit | CE PANEL | Yes | Yes | ||
Panel unit | PANEL UNIT | Yes | |||
CACD | CACD | Yes | |||
External temperature error (TEMP) | OUTER | Yes | |||
Internal temperature error (CMTMP) | CM | Yes | |||
CSL unit | CSL UNIT | Yes | |||
CSL communication failure | CSL COMM | Yes | |||
CSL voltage failure(PNLVL) | CSL | Yes | |||
Central module processor: DC/DC converter | CM DDCON | Yes | |||
Communication error between CMs | CM COMM | Yes | |||
CM voltage failure(CMPWR) | CM UNIT<CMPWR> | Yes | |||
PBC in CM | CM UNIT<CMPBC> | Yes | |||
Communication error between PBCs(CMPCO) in CM | CM PBC COMM | Yes | |||
PBC voltage failure(CPBVL) in CM | CM UNIT<CPBVL> | Yes | |||
DEI failure(CMDEI) in CM | CM UNIT<CMDEI> | Yes | |||
FC failure(CMFC) in CM | CM UNIT<FC> | Yes | |||
Battery | BATTERY | Yes | |||
Battery unit | BTU | Yes | Yes | ||
Battery unit | BBU | Yes | |||
Expanded battery unit | EX-BBU | Yes | |||
Battery control unit | BCU | Yes | Yes | ||
PC battery | BCU-PC | Yes | |||
Battery backup unit: Charger | BBUC | Yes | |||
Battery output board | BTOUTPUT | Yes | |||
Battery backup unit communication error | BBU COMM | Yes | Yes | ||
Expanded battery backup unit communication error | EX-BBU COMM | Yes | |||
Battery backup unit: Switch | BBU UNIT | Yes | |||
Expanded battery backup unit: Switch | EX-BBU CORE | Yes | |||
Battery backup unit voltage failure (BBUVL) | BBU | Yes | |||
BBU cable | BBU CABLE | Yes | Yes | ||
DACA | DACD | Yes | |||
Drive enclosure | DE | Yes | Yes | ||
Port bypass circuit | PBC | Yes | Yes | ||
Drive enclosure: Fan unit and DC/DC converter | DE FAN DDCON | Yes | |||
Device | DISK | Yes | Yes | Yes | Yes |
Drive enclosure: Primary power supply unit | DE FE | Yes | |||
Drive enclosure (10 drives enclosed): Fan | DE(10) FE | Yes | |||
Drive enclosure: Secondary power supply unit | DE BE | Yes | |||
Drive enclosure (10 drives enclosed): Fan | DE(10) FAN | Yes | |||
Drive enclosure: Panel unit | DE PANEL | Yes | Yes | ||
Drive enclosure: Fan board | DE FANBD | Yes | |||
Drive enclosure (10 drives enclosed): Fan | DE(10) FAN | Yes | |||
Drive enclosure: Back panel unit | DE BPU | Yes | |||
Drive enclosure: Power supply unit | DPSU | Yes | Yes | Yes | |
Drive enclosure (30 drives enclosed): Fan | DE(30) FAN UNIT | Yes | |||
Drive enclosure (30 drives enclosed): Fan | DE(30) FAN | Yes | |||
DE voltage failure | DE | Yes | |||
External DE temperature error | DE OUTER | Yes | |||
Internal DE temperature error | DE | Yes | |||
Central module processor: Fan | CM FAN | Yes | Yes | ||
Controller enclosure: Fan board | CE FANBD | Yes | |||
Controller enclosure: Back panel unit | CE BPU | Yes | |||
Controller enclosure: Fan unit | CE FAN UNIT | Yes | |||
Controller enclosure: Fan unit | CE FAN | Yes | |||
Controller enclosure: Front fan S | FAN UNIT S | Yes | |||
Controller enclosure: Front fan L | FAN UNIT L | Yes | |||
CM FAN Front(MFANF) | CM FAN Front | Yes | |||
CM FAN Rear(MFANR) | CM FAN Rear | Yes | |||
Controller enclosure: Power supply unit | CPSU | Yes | Yes | Yes | |
CE outlet thermal sensor | CE OUTLET THERMAL SENSOR | Yes | |||
IO board | IOB | Yes | |||
Router | RT | Yes | Yes | ||
IO board: DC/DC converter | IOB DDCON | Yes | |||
Central module: DC/DC converter | CM DDCON | Yes | Yes | ||
System control board: DC/DC converter | SVC DDCON | Yes | |||
Router: DC/DC converter | RT DDCON | Yes | |||
Port bypass circuit | PBC | Yes | Yes | ||
Port bypass circuit: DC/DC converter | PBC DDCON | Yes | |||
Communication error between PBCs (PBCCO) | PBC COMM | Yes | |||
RCI cable (DEI) | RCI CABLE | Yes | Yes | ||
FC loop | FC LOOP | Yes | Yes | ||
FC cable | FC CABLE | Yes | Yes | Yes | |
DEI cable | DEI CABLE | Yes | Yes | ||
FC EXPOSED loop | FC EXPOSED LOOP | Yes | |||
Personal computer: DC/DC converter | PC DDCON | Yes | Yes | ||
Maintenance PC | MAINTENANCE PC | Yes | |||
SCSI board | SCCI BOARD | Yes | |||
CM FLASH | FMEMBD | Yes | |||
Power supply unit | PSU/PSUDM | Yes | |||
BFCBP | FCBP | Yes | |||
Thrmistor cable | THRMISTOR CABLE | Yes | |||
PBC DIP-SW set error | PBC UNIT SETTING | Yes | |||
PBC DIP-SW count error | PBC UNIT COMBINATION | Yes |