To manage the HBA installed in a Windows server node, please install the following HBA vendor's SNIA HBA API library.
For PG-FC105, PG-FC106, PG-FC107, PG-FC201, PG-FC202, PG-FC203/203L,PG-FCD201, and Emulex's LP9000, LP9002L, LP9802, LP1050, LP1050Ex, LP11002, LPe11002
Please install HBAnyware (SNIA HBA API) according to the HBA card's instruction manual or the driver's manual.
When using the driver version v5-2.13a4 (Windows2000) with PG-FC105, this configuration is not necessary.
To use PG-FC202, PG-FC203/203L, PG-FCD201, LP11002 or LPe11002, change the $INS_DIR\Agent\bin\HBAAPI.dll to another name (for example, HBAAPI.dll.bak).
If the $INS_DIR\Agent\bin\HBAAPI.dll does not exist, file name change is not necessary.
($INS_DIR means "Program Directory" specified at the Agent instllation.)
For PG-FCD101, PG-FCD102, and Qlogic's QLA2340, QLA2342
Please install the SNIA HBA API common library (for Common HBA API Version 2.18).
Copy $INS_DIR\Agent\lib\HBAAPI.dll to $INS_DIR\Agent\bin\HBAAPI.dll.
($INS_DIR means "Program Directory" specified at the Agent instllation.)
When the same files already exist in the copy destination, copying is not necessary.
For MC-08FC11, MC-08FC31, MC-08FC41, MC-08FC51, MC-08FC61, MC-08FC71, MC-08FC81,MC-08FC91
Please install HBAnyware (SNIA HBA API) according to the HBA card's instruction manual or the driver's manual.