This section explains how to change power monitoring environment settings.
Power environment settings include power monitoring device settings and collection settings.
Use the following procedure to change collection settings:
From the RC console menu, select [Tools]-[Options].
The [Options] dialog is displayed.
In the [Options] dialog, select the "Environmental Data" category title.
The "Environmental Data" area is displayed.
In the "Environmental Data" area, change the following items.
Select "Power", to start collecting power consumption data.
Enter the time interval of the data collection (1-6 or 10).
The number of devices that can be monitored simultaneously depends on the value of this polling interval.
Polling interval | Number of devices that can be monitored simultaneously |
---|---|
1 minute | 130 |
6 minutes | 780 |
10 minutes | 1300 |
Enter storage periods for each collection rate. Data older than the configured storage period will be deleted everyday.
Click the <Apply> button.
The following settings can be changed:
Device name
Admin LAN (IP address)
SNMP community
Voltage
Comment
Complete setting modifications on the actual power monitoring device before performing this procedure.
Use the following procedure to change power monitoring device settings:
From the RC console, right-click the power monitoring device, then select [Modify]-[Registration Settings] from the popup menu.
The [Modify Power Monitoring Device] dialog is displayed.
Edit the items to be changed in the [Modify Power Monitoring Device] dialog and click the <OK> button.
The power monitoring device settings will be changed with the entered information.