Top
ETERNUS SF Storage Cruiser 14.0 User's Guidefor Virtual Storage Conductor

C.1 vscefieldsetnow Command

NAME

vscefieldsetnow - Sets up the VSC Manager for connection


SYNOPSIS

vscefieldsetnow

DESCRIPTION

This command changes or dynamically adds a VSC Manager for connection while the VSC Engine is running during the operation.

This command can be executed while the VSC Engine is running.

This command must be executed by a user with administrator privileges.


OPTIONS

None.


EXAMPLES

Case of VS900 Model 200

vsce1:admin> vscefieldsetnow

Setting up VSCManager. <cr> to skip a parameter

How many VSC Manager do you install in this system?: (1..2) [2] 2
  // Input explanation: Enter the number 2 to specify that two VSC Managers will be set up. //

Input 'IP Address' of VSC Manager 1: [192.168.1.1] 192.168.1.6
  // Input explanation: Enter new IP Address (192.168.1.6) to change the address from the one displayed. //

Input 'IP Address' of VSC Manager 2: [192.168.1.100] 
  // Input explanation: Press [ENTER] key to accept the IP Address displayed. //

[VSC Manager(1)] 
  IP Address = 192.168.1.6
[VSC Manager(2)] 
  IP Address = 192.168.1.100
Are you sure ? Yes:1 No:other -> 1
vscefieldsetnow: Operation normally end.

Other case of VS900 Model 200

BFOS:admin> vscefieldsetnow

setting up to the networks of vscengine. <cr> to skip a parameter

how many vsc manager do you install in this system? (1..2) [1] -> 2
// Input explanation: Enter the number 2 to specify that two VSC Managers will be set up. //

input 'ip address' of vsc manager 1. [192.168.1.1] 192.168.1.6
// Input explanation: Enter new IP Address (192.168.1.6) to change the address from the one displayed. //

input 'ip address' of vsc manager 2: [192.168.1.100] 
// Input explanation: Press [ENTER] key to accept the IP Address displayed. //

setting parameters are ...

Setting of this switch:
       vsce number       = vsce31
       shared id         = 1
       ip address(eth0)  = 192.168.1.110
       ip address(eth1)  = 192.168.1.111

Setting of other switch:
       vsce number       = vsce32
       shared id         = 2
       ip address(eth0)  = 192.168.1.120
       ip address(eth1)  = 192.168.1.121

Setting of VSC Manager 1:
       ip address        = 192.168.1.6

Setting of VSC Manager 2:
       ip address        = 192.168.1.100

Are you sure ? Yes:1 No:other -> 1

vscefieldsetnow : Operation normally end. 

BFOS:admin>

EXIT STATUS

0: Normal end of setting up the VSC Manager for connection.

1: Failure to set up the VSC Manager for connection.