Set the information required by the admin server to manage a virtualization switch and the information of a remote virtualization switch in a redundant configuration. Use the vscefieldset command to set this information.
This section describes the items of information to be set.
Virtualization switch number
Enter the virtualization switch number of a virtualization switch that is managed by the admin server. This must be a unique number in the admin server's range of management.
The numeric value (1 to 128) entered and prefixed with "vsce" forms the communication host name to be used. For example, enter "1" to establish a communication host name of "vsce1".
Shared ID of a virtualization switch
Assuming virtualization switches in a redundant configuration as one group, assign an identifier for the entire group.
For example, when placing two virtualization switches in a redundant configuration, set 1 for the local virtualization switch and 2 for the remote virtualization switch.
IP address of a virtualization switch
This is an IP address of Ethernet port for virtualization switch control for communication with the admin server or between virtualization switches in a redundant configuration. Set a representative IP address of Ethernet port for virtualization switch control of the virtualization switch.
Number of remote virtualization switches in a redundant configuration
Enter the number of virtualization switches in a redundant configuration minus one, which accounts for the local virtualization switch.
When two virtualization switches are in a redundant configuration, enter 1 because there is only one remote virtualization switch.
Number of admin servers
Enter the number of admin servers that manage virtualization switches.
However, enter 1 for admin servers in a cluster configuration.
IP address of an admin server
Set the IP address of an admin server that manages a virtualization switch.
When admin servers are in a cluster configuration, set the take-over IP address.