Interstage Shunsaku Data Manager Operator's Guide - Microsoft(R) Windows(R) 2000/ Microsoft(R) Windows Server(TM) 2003 - - UNIX -
Contents Index PreviousNext

Appendix A Execution Parameters in Environment Files > A.2 Conductor Environment Files

A.2.3 Entry Example

An entry example for the execution parameters in the conductor environment file is shown below.

#---The directory where the conductor log file is stored---#
LogFileFolder   "C:\Program Files\Interstage Shunsaku\Shunsaku\log\conductor\"

#---The changeover size for the conductor log file (MB)---#
LogFileSize      100

#---The number of the conductor backup log file---#
LogFileBackup    100

#---The number of days that the conductor log file will switch---#
LogFileSwitch    30

#---The storage directory for conductor performance log file---#
PfmFileFolder   "C:\Program Files\Interstage Shunsaku\Shunsaku\log\conductor\"

#---The size of conductor performance log file that will switch (MB)---#
PfmFileSize      500

#---The number of the conductor performance backup log file---#
PfmFileBackup    100

#---The number of days that the conductor performance log file will switch---#
PfmFileSwitch    30
#---The directory where the conductor core file is stored---#
CoreFileFolder  "C:\Program Files\Interstage Shunsaku\Shunsaku\core\conductor\"

#---Maximum number of responses to the application---#
AnsMax           100

#--- The director identifier for the data insertion destination---#
InsertPoint      shund1 file1 
InsertPoint      shund3 file2

#---Maximum number of connections to the conductor---#
MaxConnection    1000

#---File information---#
File             file1 shund1 shund2
File             file2 shund3 shund4

#---Domain information---#
Domain           dom1 file1 file2

#---Default File information---#
DefaultFile      file1

#---The directory where the conductor log file is stored---#
LogFileFolder   /var/opt/FJSVshnsk/log/conductor/

#---The changeover size for the conductor log file (MB)---#
LogFileSize      100

#---The number of the conductor backup log file---#
LogFileBackup    100

#---The number of days that the conductor log file will switch---#
LogFileSwitch     30

#---The storage directory for conductor performance log file---#
PfmFileFolder     /var/opt/FJSVshnsk/log/conductor/

#---The size of conductor performance log file that will switch (MB)---#
PfmFileSize       500

#---The number of the conductor performance backup log file---#
PfmFileBackup     100

#---The number of days that the conductor performance log file will switch---#
PfmFileSwitch     30

#---The directory where the conductor core file is stored---#
CoreFileFolder    /var/opt/FJSVshnsk/core/conductor/

#---Maximum number of responses to the application ---#
AnsMax            100

#---The director identifier for the data insertion destination---#
InsertPoint       shund1 file1
InsertPoint       shund3 file2

#---Maximum number of connections to the conductor---#
MaxConnection   1000

#---File information---#
File              file1 shund1 shund2
File              file2 shund3 shund4

#---Domain information---#
Domain            dom1 file1 file2

#---Default File information---#
DefaultFile       file1

Contents Index PreviousNext

All Rights Reserved, Copyright (C) FUJITSU LIMITED 2006