Interstage Shunsaku Data Manager Operator's Guide - Microsoft(R) Windows(R) 2000/ Microsoft(R) Windows Server(TM) 2003 - - UNIX - |
Contents
Index
![]() ![]() |
Chapter 6 Monitoring and Logging | > 6.4 Monitoring Setup Information |
The execution parameters specified in the system environment file can be checked.
System setup information can be obtained by executing the shunsysstate command.
Example 1
The following example shows how system setup information is displayed.
shunsysstate -n shunsaku -i Shunsaku shunsysstate 2006/01/01 19:01:00 Parameter Value Conductor shunc DirSvr1 33101 Sorter shuno1 DirSvr1 33201 Director shund1 DirSvr1 33301 33302 33102 Searcher shuns01 DirSvr1 33501 shund1 Searcher shuns02 DirSvr1 33502 shund1 CharacterCode UTF-8 ANKmix 0 KNJmix 0 SkipChar "\s,\S,\n,\t" ExtendedQuery 0 SeparateChar Default SearcherFailureEscalation 0 MonitoringStyle 0 SearchAttribute 0 DegradableSearcherCnt 1
Refer to A.1 System Environment Files for more information on the execution parameters in the system environment file.
Example 2
In the following example, system setup information is output in CSV format.
shunsysstate -n shunsaku -i -C > C:\shunwork\monitor\syssetting.csv
shunsysstate -n shunsaku -i -C > /home/shunsaku/monitor/syssetting.csvContent of syssetting.csv
"Parameter","Value" "Conductor","shunc DirSvr1 33101" "Sorter","shuno1 DirSvr1 33201" "Director","shund1 DirSvr1 33301 33302 33102" "Searcher","shuns01 DirSvr1 33501 shund1" "Searcher","shuns02 DirSvr1 33502 shund1" "CharacterCode","UTF-8" "ANKmix",0 "KNJmix",0 "SkipChar","\s,\S,\n,\t" "ExtendedQuery",0 "SeparateChar","Default" "SearcherFailureEscalation",0 "MonitoringStyle",0 "SearchAttribute",0 "DegradableSearcherCnt",1
The column headings are as follows:
CSV files are output using the following format:
- Enclose character string items in double quotes (").
- Do not enclose numerical values in double quotes (").
Contents