62000 WARNING: spare disk disk too small

 

[Explanation]

The size of disk is too small and may not function as a spare disk.

[Resolution]

Specify a larger disk, and execute the command again.

 


 

62001 WARNING: device: write error, errno=errno

 

[Explanation]

A write error occurred in physical disk device.

[Resolution]

If device is a write-locked disk that is connected to a switch group, no action is required. Otherwise, remove device from the class and check the status of device.

 


 

62002 WARNING: group: free blocks are reduced

 

[Explanation]

Free blocks on group was reduced.

[Resolution]

You may not be able to create a volume with sufficient capacity.
Execute commands as needed and attempt recovery.

 


 

62003 WARNING: another disk must be connected to group

 

[Explanation]

You must connect another disk to group.

[Resolution]

Connect another disk.

 


 

62004 WARNING: object: copying not completed successfully

 

[Explanation]

Synchronization copying did not complete successfully.

[Resolution]

Disk failure may have occurred. Identify the cause by referring to GDS log message and syslog message.

 


 

62005 WARNING: object: gave up wait for the completion of copying by a cancel request

 

[Explanation]

Synchronization copying was canceled before completion.

[Resolution]

Check the status of the object object. If the copying is in progress, there is no need to work around. If it is not in progress, re-execute the copying where it is necessary. For details, see "Command Reference."

 


 

62007 WARNING: group: no spare disk available

 

[Explanation]

There is no valid spare disk in group.

[Resolution]

Define a spare disk as needed.

 


 

62008 WARNING: object.volume: cannot attached due to in status status

 

[Explanation]

Slice object.volume could not be attached since it is in status status.

[Resolution]

Check the slice status and cancel status status as needed.

 


 

62009 WARNING: volume: no need to resize volume

 

[Explanation]

There was no need to resize the volume volume.

[Resolution]

No particular resolution required.

 


 

62010 WARNING: disk.volume: special file(s) not found

 

[Explanation]

Special file for slice disk.volume could not be found.

[Resolution]

No particular resolution required.

 


 

62011 WARNING: node: node in stopped status

 

[Explanation]

node is in STOP status.

[Resolution]

No particular resolution required. However, promptly activating the node is recommended.

 


 

62012 WARNING: node: node in abnormal status

 

[Explanation]

node is in abnormal status.

[Resolution]

No particular resolution required. However, promptly recovering the node and activating it normally is recommended.

 


 

62013 WARNING: object: already in status status

 

[Explanation]

object is already in status status.

[Resolution]

No particular resolution required.

 


 

62014 WARNING: disk : device : write error, errno=errno

 

[Explanation]

A write error occurred on physical disk device.

[Resolution]

If device is a write-locked disk that is connected to a switch group, no action is required. In other situations, have device switchable and check its status.

 


 

62015 WARNING: disk : device : node: write error, errno=errno

 

[Explanation]

A write error occurred on physical disk device on node node.

[Resolution]

If device is a write-locked disk that is connected to a switch group, no action is required. In other situations, have device switchable and check its status.

 


 

62016 RNING: object: no need to update attribute value

 

[Explanation]

There was no need to change object attributes.

[Resolution]

No particular resolution required.

 


 

62017 WARNING: pslice: entry in /etc/fstab not updated, unsupported file system type fstype

 

[Explanation]

Entry in the /etc/fstab file relevant to the physical slice pslice was not updated since fstype is a file system type not supported by the sdxroot command.

[Resolution]

Edit the /etc/fstab file or change the file system configuration according to need.

 


 

62018 WARNING: correct /etc/fstab and file system configuration before rebooting, or system may not be booted

 

[Explanation]

The /etc/fstab file contains an invalid entry. When an entry for a file system, such as / (root), /usr, and /var, essential to system start-up is invalid, it will be impossible to start the system if rebooted.

[Resolution]

Refer to a GDS's WARNING message output just before this message and pinpoint the invalid entry in the /etc/fstab file. Be sure to repair the /etc/fstab file and the file system configuration as needed prior to rebooting the system.

 


 

62019 WARNING: volume: entry in /etc/fstab not updated, unsupported file system type fstype

 

[Explanation]

Since file system type fstype is not supported, entry in /etc/fstab file for volume could not be updated.

[Resolution]

Directly edit /etc/fstab as necessary.

 


 

62020 WARNING: ignored parameter param for EC

 

[Explanation]

Since EC function will be used for copying, parameter param was ignored.

 


 

62021 WARNING: ignored parameter param for OPC

 

[Explanation]

Since OPC function will be used for copying, parameter param was ignored.

 


 

62022 WARNING: ignored parameter param for TimeFinder

 

[Explanation]

Parameter param was ignored for copying with TimeFinder.

 


 

62023 WARNING: ignored parameter param for SRDF

 

[Explanation]

Parameter param was ignored for copying with SRDF.

 


 

62024 WARNING: proxy: no session

 

[Explanation]

No copy session exists between the proxy proxy and the master

[Resolution]

No special action is required.

 