9.3.2.1 Procedure for Applying Corrections by Stopping an Entire System

This section explains the procedure for applying corrections by stopping the entire cluster system. An example of a two-node 1:1 standby configuration is used here.

mark2Flow of operation

mark2Procedure

Copy the correction to be applied to each node to the local file system in advance.

  1. Stop RMS.

    Execute hvshut -a on either cluster node to stop the operation of RMS.

  2. Shut down all nodes.

     

  3. Boot in single-user mode.

    Boot all the nodes that were shut down in single-user mode.

  4. Mount the local file system.

    Mount the required local file system on all the nodes.

  5. Apply corrections.

    Apply the corrections that were copied to the local file system in advance.

  6. Reboot.

    After applying the corrections, reboot the nodes by using shutdown -r.