If panicinfo_setup fails, the following messages will be output to the standard error output according to the cause.
Content:
Execution of the <command> command failed.
Corrective action:
Check the command and execute it again.
Content:
The <command> command failed on the <node> node.
Corrective action:
Check the command and execute the <command> command on the <node> node again.
Content:
Execution of the <command> command timeout.
Corrective action:
Check the command and execute the <command> command on the <node> node again.
Content:
Distribution of the index file to <node> node failed.
Corrective action:
Confirm that the CF services (CFSH, CFCP) have started normally.
Content:
Distribution of the panicinfo definition file to <node> node failed.
Corrective action:
Confirm that the CF services (CFSH, CFCP) have started normally.
Content:
Reading of the Netdump client settings on the <node> node failed.
Corrective action:
Confirm that Netdump is normally set up.
Content:
The panicinfo configuration file already exists.
Corrective action:
Enter "I" to initialize the panicinfo configuration file, "C" to distribute the panicinfo configuration file on the command execution node, and "Q" to terminate the command.
Content:
Changing of the index file mode on <node> node failed.
Corrective action:
Confirm that the "chmod" command can be executed normally on <node> node for the "/etc/opt/FJSVcllkcd/etc/SA_lkcd.idx" file, and then re-execute the command.
Content:
Updating of rcsd.cfg failed on the <node> node.
Corrective action:
Confirm that the "/etc/opt/SMAW/SMAWsf/rcsd.cfg" file is included in the <node> node and then, re-execute the command.
Content:
Changing of the owner on the <node> node failed.
Corrective action:
Confirm that the "chown" command can be executed for the "/etc/opt/FJSVcllkcd/etc/SA_lkcd.idx" file and for the "/etc/opt/SMAW/SMAWsf/rcsd.cfg" file on the <node> node, and then re-execute the command.
Content:
Changing of the owner group on the <node> node failed.
Corrective action:
Confirm that the "chgrp" command can be executed for the "/etc/opt/FJSVcllkcd/etc/SA_lkcd.idx" file and for the "/etc/opt/SMAW/SMAWsf/rcsd.cfg" file on the <node> node, and then re-execute the command.
Content:
Changing of the panicinfo configuration file mode on <node> node failed.
Corrective action:
Confirm that the "chmod" command can be executed normally on <node> node for the "/etc/panicinfo.conf" file, and then re-execute the command.
Content:
Changing of the owner on the <node> node failed.
Corrective action:
Confirm that the "chmod" command can be executed normally for the "/etc/panicinfo.conf" file on the <node> node, and then re-execute the command.
Content:
Changing of the owner group on the <node> node failed.
Corrective action:
Confirm that the "chgrp" command can be executed normally for the "/etc/panicinfo.conf" file on the <node> node, and then re-execute the command.
Content:
Internal error.
Corrective action:
Copy this message, and then contact your Fujitsu systems engineer (SE).
Content:
The Shutdown Facility configuration file is not found. You might not have completed configuring the Shutdown Facility.
Corrective action:
Confirm that Shutdown Facility configuration is completed then execute the command again.
Content:
Reading Shutdown Facility configuration failed. You might have set the Shutdown Facility incorrectly.
Corrective action:
Confirm that Shutdown Facility configuration is correct then execute the command again.
Content:
Reading Shutdown Agent configuration failed. You might have set the Shutdown Agent incorrectly.
Corrective action:
Confirm that Shutdown Agent configuration is correct then execute the command again.
Content:
Creation of the <file name> file failed.
Corrective action:
Confirm that the <file name> file can be created then execute the command again.
Content:
The RSB Shutdown Agent configuration file is not found. You might not have completed configuration the RSB Shutdown Agent.
Corrective action:
Confirm that RSB Shutdown Agent configuration is completed then execute the command again.
Content:
The Blade Shutdown Agent configuration file is not found. You might not have completed configuration the Blade Shutdown Agent.
Corrective action:
Confirm that Blade Shutdown Agent configuration is completed then execute the command again.
Content:
The IPMI Shutdown Agent configuration file is not found. You might not have completed configuration the IPMI Shutdown Agent.
Corrective action:
Confirm that IPMI Shutdown Agent configuration is completed then execute the command again.