PRIMECLUSTER Installation and Administration Guide 4.2 (Linux)
Contents Index PreviousNext

Appendix D Messages

D.1 Searching for a Message

This section explains the procedure for searching for a message reference.

The PRIMECLUSTER display formats are classified into five types. Determine the reference according to the format of the displayed message.

mark1Display format 1

FJSVcluster:severity:program:message-number:message 

severity:

Indicates the message severity level.
There are five message severity levels. Stop (HALT), Information (INFO), Warning (WARNING), Error (ERROR), and Question (QUESTION).

program:

Indicates the name of the program that outputs this message.

message-number:

Indicates the message number.

message:

Indicates the message text.

mark2Search procedure

After confirming the severity and message-number, determine the reference by referring to the table below.

severity

message-number

Reference

Stop (HALT)

0100, 0101, 0102

CF Configuration and Administration Guide

10.10.1 HALT Messages

Information (INFO)

2620, 2621, 2622, 2700, 2701

Information Messages

2100, 2200, 2201, 2202, 2203, 2204, 2205, 3200, 3201, 3202, 3203, 3204, 3205, 3206

CF Configuration and Administration Guide

10.10.2 INFORMATION messages

Warning (WARNING)

5200

CF Configuration and Administration Guide

10.10.3 WARNING messages

Error (ERROR)

6000, 6001, 6002, 6003, 6004, 6007, 6009, 6208, 6615, 6616, 6617, 6618, 6619, 6621, 6623, 6624, 6651, 6680, 6750, 6751, 6752, 6753, 6754, 6755, 6817

Error Messages

6000-10, 6021, 6025, 6200-23, 6226, 6300-1, 6600-4, 6606-8, 6611, 6614-16, 6653, 6661, 6665, 6668, 6675, 6680, 6900-4, 6910-1, 7500-22, 7535-43, 7545-6

CF Configuration and Administration Guide

10.10.4 ERROR messages

Question (QUESTION)

1421, 1422, 1423

Operator Intervention Messages

mark1Display format 2

command-name:message

command-name:

Indicates the command name.

message:

Indicates the message (describing the phenomenon, message number, reason, etc.).

mark2Search procedure

Messages of display format 2 are described in the CF Configuration and Administration Guide. Confirm command-name, and then determine the reference by referring to the following table:

Function

command-name

Reference in the CF Configuration and Administration Guide

Cluster node configuration

cfconfig

10.1 cfconfig message

CIP2.0 start/stop

cipconfig

10.2 cipconfig message

Outputting the node communication state

cftool

10.3 cftool message

Outputting and manipulating quorum information

rcqconfig

10.4 rcqconfig message

rcqquery

10.5 rcqquery message

CF execution

CF

10.6 CF runtime messages

mark1Display format 3

(SMAWsf,number1,number2):message

number1,number2:

Indicates the message number.

message:

Indicates the message.

mark2Search procedure

Messages of display format 3 are described in CF Configuration and Administration Guide.

Confirm number1 and number2, and then determine the reference by referring to the table below.

Operation

(number1-number2)

Reference location in CF Configuration and Administration Guide

Shutdown facility

(10, 2)-(10, 12)

(10, 15)-(10, 17), (10, 19), (10, 20)

(10, 23), (10, 101)

(30, 2)-(30, 10), (30, 12)-(30, 17)

(50, 3)-(50, 4), (50, 6), (50, 9)

10.11 Shutdown Facility

mark1Display format 4

(err-code,message-number):message

err-code:

Indicates the error code.

message-number:

Indicates the message number.

message:

Indicates the message.

mark2Search procedure

Messages of display format 4 are described in the "PRIMECLUSTER Reliant Monitor Service (RMS) with Wizard Tools Configuration and Administration Guide." Confirm err-code and message-number, and then determine the reference by referring to the table below.

Operation/state

err-code

message-number

Reference location in RMS Troubleshooting Guide

switchlog

ADC

1, 2, 3, 4, 5, 15, 17, 18, 20, 25, 27, 30, 31, 32, 33, 34, 35, 37, 38, 39, 41, 43, 44, 45, 46, 47, 48, 49, 57, 58, 59, 60, 61, 62, 63

3 Non-fatal error messages

ADM

55, 57, 58, 59, 60, 62, 63, 67, 70, 95, 96

BM

8, 14, 52, 54, 68

CML

11, 12, 17, 18, 19, 20, 21

CRT

1, 2, 3, 4

CUP

2, 3, 5, 7, 8

DET

1, 3, 4, 5, 6, 7, 12, 13, 14, 24, 28, 33

GEM

4

INI

1, 9

QUE

13

SCR

8, 20

SWT

4, 20, 25, 26, 45

SYS

1, 8, 13, 14, 15, 17, 48, 49, 50, 84, 90, 93, 94, 97, 98

UAP

1, 5, 6, 7, 8, 9, 15, 16, 19, 21, 22, 23, 24, 27, 28, 29, 32, 33, 35, 41, 42

US

5, 6, 31

WLT

1, 3

WRP

3, 4, 9, 11, 12, 14, 15, 16, 17

RMS error

ADC

16, 21

4 Fatal error messages

ADM

1, 2

BM

3, 49, 51, 58, 67

CML

14

CMM

1, 2, 3

DET

8, 9, 16

HVC

14

INI

7

MIS

4

QUE

1, 2, 5, 6, 11, 12

SCR

4, 5, 10, 12, 13, 15, 18

SYS

33, 52

UAP

36

US

1

mark1Display format 5 (other)

If the display format is other than display format 1 to 4, see the following:


Contents Index PreviousNext

All Rights Reserved, Copyright(C) FUJITSU LIMITED 2006