Machine Administration Guide 2.6
Contents Index PreviousNext

Chapter 4 Command Reference

4.10 inst2comp (1M)

Name
inst2comp - Physical slot name change command
Format
/usr/sbin/FJSVmadm/inst2comp inst_name
Function
The inst2comp command displays ap_id based on the adapter driver instance name of the PCI card.
Specify the instance name of the adapter driver in inst_name.
Execution example
To display the name of the PCI physical slot where an adapter controlled by glm2 ismounted:
example% /usr/sbin/FJSVmadm/inst2comp glm2
pcipsy1:R0B01-PCI#slot01
End status
The end status can be:
0: Normal end
1: The specified driver instance does not exist.
Other than 0 and 1: Another type of error

Contents Index PreviousNext

All Rights Reserved, Copyright(C) FUJITSU LIMITED 2001-2005
All Rights Reserved, Copyright (C) PFU LIMITED 2001-2005