| Part 2 Serial Port Driver Features (PRIMEPOWER800/900/1000/1500/2000/2500/HPC2500 and GP7000F Models 1000/2000) | > Chapter 8 Command Reference |
iompadm - multi path control command
/usr/opt/FJSViomp/bin/iompadm [-p] [-c fjmse] subcommand [parameter ...]
FJSVse(or FJSVsec), FJSViomp
iompadm(1M) on the duplicated console paths displays the status of communication paths composed of instances (the units of duplicated communication paths), and restores the communication path where a failure occurs.
You can display the status of communication paths or restore them using a combination of the specified subcommand and parameter.
A communication path is a path that is used for communications between a system serial port and System Management Console.
If in a partition, serial ports on the first and second system boards are used as the communication path by default.
The communication path names will be "/dev/fjse/0" and "/dev/fjse/1."
The following options are available:
| Subcommand | Description |
| Info | Displays the configuration information of the specified instance or all instances, and the status of the communication paths. |
| Status | Displays the status of the specified communication path. |
| Ident | Displays the class to which the specified communication path belongs. |
| Probe | Displays the instance and class to which the specified communication path belongs. |
| Recover | Restores the specified communication path. |
| Start |
After the recover subcommand is running, this subcommand makes the specified communication path available for communicating. |
| Active | Changes the status of the specified communication path to use. |
| Version | Displays the version information for this product. |
| Help | Displays the usage of the iompadm command. |
This command returns the following values:
8.1.1 iompadm subcommand
Contents