Enhanced Support Facility 2.6 User's Guide
Contents Index PreviousNext

Part 1 SCF Driver Features> Chapter 5 Daemon Messages> 5.1 SCF Monitoring Daemon

5.1.4 For GP7000F models 1000/2000 and PRIMEPOWER 800/1000/2000


 

pwrctrld: Power switch is pressed. Press power switch again within 30 seconds to start shutdown procedure

Meaning
The POWER switch was pressed. Pressing it again within 30 seconds starts the shutdown process.

 

pwrctrld: power switch ignored.

Meaning
The POWER switch was pressed but was ignored by the scftool(1M) setting.

 

pwrctrld: failed to start (xxx)

Meaning
Could not start the SCF monitoring daemon. xxx represents the system call that failed.
Action
Allocate memory or a swap area.

 

pwrctrld: failed to open pwrctrld pid file.

Meaning
Could not create the PID file.
Action
Check the capacity of the root file system and whether it is mounted in a write-enabled state.

 

pwrctrld: halt system.

Meaning
System shut down due to an error.

 

pwrctrld: failed to start power switch procedure (xxx)

Meaning
Pressing the POWER switch failed to initiate the shutdown procedure. xxx represents the system call that failed.
Action
Allocate memory or a swap area.

 

pwrctrld: failed to start UPS AC down procedure (xxx)

Meaning
Failed to initiate UPS switch over procedure when power failed. xxx represents the system call that failed.
Action
Allocate memory or a swap area.

 

pwrctrld: failed to start SCFHALT procedure (xxx)

Meaning
Failed to initiate SCFHALT procedure. xx represents the system call that failed.
Action
Allocate memory or a swap area.

 

pwrctrld: Power failure was detected. Waiting power to be supplied for n second(s). RCI addr = 0xXXX(0xYYY)

Meaning
Power down occurred. 0xXXX represents the RCI address of UPS. When the dual power feed configuration is defined, 0xYYY represents the RCI address of UPS pairs.
Action
Check the UPS.

 

pwrctrld: Power is supplied. The system keeps services on. RCI addr = 0xXXX(0xYYY)

Meaning
Power was restored. 0xXXX represents the RCI address of UPS. When the dual power feed configuration is defined, 0xYYY represents the address of UPS pairs.

 

pwrctrld: failed to start SHUTDOWN procedure (xxx)

Meaning
Failed to initiate SHUTDOWN procedure. xxx represents the system call that failed.
Action
Allocate memory or a swap area.

 

pwrctrld: failed to start RCI-POFF procedure (xxx)

Meaning
Failed to initiate RCI power down procedure. xxx represents the system call that failed.
Action
Allocate memory or a swap area.

 

/etc/rc0.d/K00FJSVscf: scfreport shutdown was executed.

Meaning
Reported the start of system shutdown to SCF device.
This message might be stored in message log (/var/adm/messages) as "daemon.error". However, it is not abnormal.

 

FJSVscf: The system power down is executed 30 seconds later.

Meaning
The power off of the system is begun 30 seconds later. This message shows the state.
This message might be stored in message log (/var/adm/messages) as "daemon.error". However, it is not abnormal.