5.1.4 For GP7000F models 1000/2000 and PRIMEPOWER 800/1000/2000
pwrctrld: Power switch is pressed. Press power switch again within 30 seconds to start shutdown procedure
- Meaning
- The POWER switch was pressed. Pressing it again within 30 seconds starts the shutdown process.
pwrctrld: power switch ignored.
- Meaning
- The POWER switch was pressed but was ignored by the scftool(1M) setting.
pwrctrld: failed to start (xxx)
- Meaning
- Could not start the SCF monitoring daemon. xxx represents the system call that failed.
- Action
- Allocate memory or a swap area.
pwrctrld: failed to open pwrctrld pid file.
- Meaning
- Could not create the PID file.
- Action
- Check the capacity of the root file system and whether it is mounted in a write-enabled state.
pwrctrld: halt system.
- Meaning
- System shut down due to an error.
pwrctrld: failed to start power switch procedure (xxx)
- Meaning
- Pressing the POWER switch failed to initiate the shutdown procedure. xxx represents the system call that failed.
- Action
- Allocate memory or a swap area.
pwrctrld: failed to start UPS AC down procedure (xxx)
- Meaning
- Failed to initiate UPS switch over procedure when power failed. xxx represents the system call that failed.
- Action
- Allocate memory or a swap area.
pwrctrld: failed to start SCFHALT procedure (xxx)
- Meaning
- Failed to initiate SCFHALT procedure. xx represents the system call that failed.
- Action
- Allocate memory or a swap area.
pwrctrld: Power failure was detected. Waiting power to be supplied for n second(s). RCI addr = 0xXXX(0xYYY)
- Meaning
- Power down occurred. 0xXXX represents the RCI address of UPS. When the dual power feed configuration is defined, 0xYYY represents the RCI address of UPS pairs.
- Action
- Check the UPS.
pwrctrld: Power is supplied. The system keeps services on. RCI addr = 0xXXX(0xYYY)
- Meaning
- Power was restored. 0xXXX represents the RCI address of UPS. When the dual power feed configuration is defined, 0xYYY represents the address of UPS pairs.
pwrctrld: failed to start SHUTDOWN procedure (xxx)
- Meaning
- Failed to initiate SHUTDOWN procedure. xxx represents the system call that failed.
- Action
- Allocate memory or a swap area.
pwrctrld: failed to start RCI-POFF procedure (xxx)
- Meaning
- Failed to initiate RCI power down procedure. xxx represents the system call that failed.
- Action
- Allocate memory or a swap area.
/etc/rc0.d/K00FJSVscf: scfreport shutdown was executed.
- Meaning
- Reported the start of system shutdown to SCF device.
This message might be stored in message log (/var/adm/messages) as "daemon.error". However, it is not abnormal.
FJSVscf: The system power down is executed 30 seconds later.
- Meaning
- The power off of the system is begun 30 seconds later. This message shows the state.