WARNING: FJSVscf: _init: ddi_soft_state_init failed.

Meaning
Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_soft_state_init(9F).
Action
Allocate memory since there might not be enough kernel resources.

 

WARNING: FJSVscf: _init: mod_install failed.

Meaning
Failed to incorporate the SCF driver into the system due to the abnormal termination of mod_install(9F) (incorporates the driver into the system).
Action
Allocate memory since there might not be enough kernel resources.

 

WARNING: FJSVscf: scf_probe: ddi_soft_state_zalloc failed.

Meaning
Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_soft_state_zalloc(9F) (allocates an area for the driver).
Action
Allocate memory since there might not be enough kernel resources.

 

WARNING: FJSVscf: scf_probe: ddi_get_soft_state failed.

Meaning
Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_get_soft_state(9F) (gets an area for the driver).
Action
Allocate memory since there might not be enough kernel resources.

 

WARNING: FJSVscf: scf_probe: ddi_dev_nregs failed.

Meaning
The register information in the SCF device is incorrect.
Action
Check the state of the SCF device.

 

WARNING: FJSVscf: scf_attach: ddi_get_soft_state failed.

Meaning
Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_get_soft_state(9F)(gets an area for the driver).
Action
Allocate memory since there might not be enough kernel resources.

 

WARNING: FJSVscf: scf_attach: ddi_soft_state_zalloc failed.

Meaning
Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_soft_state_zalloc(9F) (allocates an area for the driver).
Action
Allocate memory since there might not be enough kernel resources.

 

WARNING: FJSVscf: scf_attach: ddi_get_soft_iblock_cookie failed.

Meaning
Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_get_soft_iblock_cookie(9F) (allocates resources for interrupt processing).
Action
Allocate memory since there might not be enough kernel resources.

 

WARNING: FJSVscf: scf_attach: ddi_create_minor_node failed.

Meaning
Failed to incorporate the SCF driver into the system because the creation of the device minor node failed.
Action
Make sure there is enough room in the /device file system.

 

WARNING: FJSVscf: scf_attach: ddi_add_intr failed.

Meaning
Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_add_intr(9F) (registers interrupt functions).
Action
Allocate memory since there might not be enough kernel resources.

 

WARNING: FJSVscf: scf_map_regs: ddi_regs_map_setup failed.

Meaning
Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_regs_map_setup(9F) (maps register).
Action
Allocate memory since there might not be enough kernel resources.

 

WARNING: FJSVscf: scf_map_regs: ddi_dev_regsize failed.

Meaning
Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_dev_regsize(9F) (gets the register size).
Action
Check the state of the SCF device.

 

WARNING: FJSVscf: scf_chpoll: ddi_get_soft_state failed

Meaning
poll(2) terminated abnormally due to the abnormal termination of ddi_get_soft_state(9F) (gets an area for the driver).
Action
Allocate memory since there might not be enough kernel resources.

 

WARNING: FJSVscf: scf_detach: ddi_get_soft_state failed

Meaning
Could not detach the SCF driver due to the abnormal termination of ddi_get_soft_state(9F) (gets an area for the driver).
Action
Allocate memory since there might not be enough kernel resources.

 

WARNING: FJSVscf: scf_open: ddi_get_soft_state failed

Meaning
Could not open the SCF driver due to the abnormal termination of ddi_get_soft_state(9F) (gets an area for the driver).
Action
Allocate memory since there might not be enough kernel resources.

 

WARNING: FJSVscf: scf_close: ddi_get_soft_state failed

Meaning
Could not close the SCF driver due to the abnormal termination of ddi_get_soft_state(9F) (gets an area for the driver).
Action
Allocate memory since there might not be enough kernel resources.

 

WARNING: FJSVscf: scf_read: ddi_get_soft_state failed

Meaning
Could not read the SCF driver due to the abnormal termination of ddi_get_soft_state(9F) (gets an area for the driver).
Action
Allocate memory since there might not be enough kernel resources.

 

WARNING: FJSVscf: scf_ioctl: ddi_get_soft_state failed

Meaning
SCF driver ioctl failed due to the abnormal termination of ddi_get_soft_state(9F) (gets an area for the driver).
Action
Allocate memory since there might not be enough kernel resources.

 

WARNING: FJSVscf: scf_rfantest: redundant fan test failed.

Meaning
Failed to start the redundant fan test that is performed periodically within the SCF driver.
Action
Check the state of the SCF device.

 

NOTICE: FJSVscf: cannot set watchdog. SCF busy.

Meaning
Failed to issue the CPU monitoring command to the SCF device.
Action
Check the state of the SCF device.

 

FJSVscf: ignoring debug enter sequence

Meaning
STOP-A was entered while the MODE switch on the operator panel was set to SECURE.

 

FJSVscf: allowing debug enter

Meaning
STOP-A was entered.

 

WARNING: FJSVscf: SCF went to offline mode and was restarted

Meaning
SCF entered the OFFLINE state and was reset.
Action
Check the state of the SCF device.

 

NOTICE: FJSVscf: scf_reset: kmem_alloc failed. cannot dump firm area

Meaning
Failed to allocate memory and get a dump from the SCF device firmware area when the SCF device was reset.
Action
Allocate memory since there might not be enough kernel resources.

 

NOTICE: FJSVscf: SCF online

Meaning
Resetting of the SCF device completed, and the device entered the ONLINE state.

 

WARNING: FJSVscf: scf_intr: Unexpected POFF interrupt occurred

Meaning
A POWER switch interrupt occurred while the toggle switch on the operator panel was set to SECURE.

 

NOTICE: FJSVscf: AC power down (PFAIL)

Meaning
A cutoff in power supply was detected.

 

WARNING: FJSVscf: scf_intr: Unexpected EXTOD interrupt occurred

Meaning
Detected an EXTOD interrupt.
Action
Check the state of the SCF device.

 

WARNING: FJSVscf: fan unit failure, FAN#?

Meaning
Detected a fan unit failure. FAN#? represents the fan unit number.
Action
Check the fan that had its number displayed.

 

WARNING: FJSVscf: power supply unit failure, FEP#?

Meaning
Detected a power supply unit failure. FEP#? represents the power supply unit number.
Action
Check the power supply unit that had its number displayed.

 

WARNING: FJSVscf: thermal alarm (X), SENSOR#?

Meaning
Detected an abnormal temperature.
X is a number representing the cause.
   1 : Ambient temperature low temperature warning
   2 : Ambient temperature low temperature alarm
   3 : Ambient temperature high temperature warning
   4 : Ambient temperature high temperature alarm
   5 : Unit/Processor low temperature warning, or sensor failure
   6 : Unit/Processor low temperature alarm, or sensor failure
   7 : Unit/Processor high temperature warning
   8 : unit/processor high temperature alarm
#? represents the sensor ID.
Action
Check the environment where the unit is set up. Also make sure there is nothing wrong with the inside of the unit.

 

WARNING: FJSVscf: AC power down was detected. UPS is activated.

Meaning
Power is now being supplied by the UPS due to a power down.

 

FJSVscf: AC power recovered

Meaning
Power was restored.

 

WARNING: FJSVscf: UPS low battery, UPS#?

Meaning
Power from the UPS has run out. UPS#? represents the UPS number.
Action
Charge the UPS battery.

 

WARNING: FJSVscf: UPS failure, UPS#?

Meaning
Detected a UPS failure (either a UPS hardware failure, UPS failure, or UPS circuit protector failure). UPS#? represents the UPS number.
Action
Check to make sure that nothing is wrong with the UPS.

 

WARNING: FJSVscf: SCF battery alarm, BATTERY#?

Meaning
Problem detected in the battery backing up SCF SRAM. #? represents the battery number.
Action
Check the battery.

 

NOTICE: FJSVscf: caught cpu watchdog alarm

Meaning
A CPU monitoring timeout occurred during CPU monitoring.
Action
Allocate memory since there might not be enough kernel resources.

 

NOTICE: FJSVscf: device sense Sub Code = 0x? is not support

Meaning
The SCF device reported sensor information that is not supported by the driver. 0x? represents the sub code of the sensor information that was reported.
Action
Check the state of the SCF device.

 

WARNING: FJSVscf: scf cmd (0x?) incomplete

Meaning
The SCF device could not complete a command within the prescribed time. 0x? represents the command code that could not be completed.
Action
Check the state of the SCF device.

 

WARNING: FJSVscf: scf cmd (0x?) failed. SCF hard error

Meaning
The command could not complete successfully on the SCF device due to a hardware error. 0x? represents the command code that ended in an error.
Action
Check the state of the SCF device.

 

WARNING: FJSVscf: scf cmd (0x?) failed. SCF RCI error

Meaning
The command could not complete successfully on the SCF device due to an RCI error. 0x? represents the command code that ended in an error.
Action
Check the state of the SCF device.

 

WARNING: FJSVscf: scf cmd (0x?) failed by unknown error (yy)

Meaning
The command could not complete successfully on the SCF device due to an undefined error. 0x? represents the command code that ended in an error and yy is the error code on the SCF device.
Action
Check the state of the SCF device.

 

WARNING: FJSVscf: SCF hardware error was detected (error status register value)

Meaning
SCF hardware error occurred.
Action
If this message was issued repeatedly, check the SCF device.

 

FJSVscf: kstat_create failed

Meaning
kstat_create failed.
Action
Allocate memory since there might not be enough kernel resources.

 

FJSVscf: switch status is unknown

Meaning
There is a problem with the panel switch setting.
Action
Check the state of the SCF device.

 

FJSVscf: kstat memory allocation error

Meaning
There is not enough memory.
Action
Allocate more memory.

 

WARNING: FJSVscf: no devise sense (interrupt status-1 register xx)

Meaning
An interruption that should have sensed information was detected, but no sensed information was got. xx represents the value in the interrupt status-1 register.
Action
Check the state of the SCF device.

 

WARNING: FJSVscf: Unexpected interrupt (interrupt status-1 register xx)

Meaning
An undefined interruption was detected. xx represents the value in the interrupt status-1 register.
Action
Check the state of the SCF device.

 

WARNING: FJSVscf: SCF HALT was detected. (halt status register xx)

Meaning
SCFHALT was detected. xx represents the value in the halt status register.
Action
Check the state of the SCF device.

 

WARNING: FJSVscf: scf cmd (0x?) failed. SCF buffer full, (yy) times repeated

Meaning
Sending a command to SCF device was repeated (yy) times due to a full command buffer on the SCF device. But they were not processed normally. 0x? represents the command code that ended in an error.
Action
Check the state of SCF device.

 

WARNING: FJSVscf: scf_map_regs: ddi_dev_regsize failed. (Ebus T.O. register)

Meaning
ddi_dev_regsize(9F) (gets register size) terminated abnormally.
Action
Check to make sure that nothing is wrong with the hardware(Ebus).

 

WARNING: FJSVscf: scf_map_regs: ddi_regs_map_setup failed. (Ebus T.O. register)

Meaning
ddi_regs_map_setup(9F) (maps register) terminated abnormally.
Action
Allocate memory since there might not be enough kernel resources.

 

WARNING: FJSVscf: scf_icotl: Status Check Timeout Control command timeout

Meaning
The Status Check Timeout Control command of the SCF could not complete within the prescribed time.
Action
Check the state of the SCF device.

 

WARNING: FJSVscf: EBus TimeOut. EBus T.O. Status register = 0x?.

Meaning
A Ebus timeout occurred. ? represents the value in the Ebus Timeout Status register.
Action
Check to make sure that nothing is wrong with the hardware(Ebus).

 

WARNING: FJSVscf: scf_intr: cannot get p-off factor.

Meaning
Could not get the power on/off factor from the SCF.
Action
Check the state of the SCF device.

 

panic[cpuX]/thread=0xXXXXXXXX: FJSVscf: panic request from RCI 0xXXXXXXXX

Meaning
The RCI device that has RCI address of ? requested the system panic.
Action
This message shows the state.
However, at the cluster environment etc. , another node (RCI address 0xXXXXXXXX) which detected abnormality issues the panic instruction to this node via RCI. And, when OS panic is executed, this node outputs this message.
Please investigate this node from information on another node (RCI address 0xXXXXXXXX).

 

WARNING: FJSVscf: cannot report PANIC.

Meaning
Could not notify the system panic on the other HOST when it occurred.

 

panic[cpuX]/thread=0xXXXXXXXX: FJSVscf: memory dumping due to pressing REQUEST switch.

Meaning
Started saving memory dump due to the press of REQUEST switch

 

NOTICE: FJSVscf: pressed REQUEST switch in auto mode, no memory dumping.

Meaning
REQUEST switch was pressed, but as the MODE switch is in AUTO position, memory dump was not saved.

 

WARNING: FJSVscf: cannot send command due to SCF busy.

Meaning
Failed to send commands due to busy status of the SCF device
Action
Check the state of the SCF device.

 

WARNING: FJSVscf: SCF error. System Status Register = XX unknown status.

Meaning
The value of System Status Register was undefined value(XX).
Action
Check the state of the SCF device.

 

WARNING: FJSVscf: power supply unit failure, BE#?

Meaning
Detected a BE power supply unit failure. BE#? represents the power supply unit number.
Action
Check the power supply unit that had its number displayed.

 

WARNING: FJSVscf: SCF went to offline mode again.

Meaning
SCF entered the ONLINE state after resetting the SCF device, but SCF entered the OFFLINE state again before reporting "System Running."
Action
Check the state of the SCF device.

 

WARNING: FJSVscf: SCF did not become online.

Meaning
SCF did not enter the ONLINE state after resetting the SCF device.
Action
Check the state of the SCF device.

 

WARNING: FJSVscf: scf_report_from_intr: failed to report System Running.

Meaning
SCF entered the ONLINE state after resetting the SCF device. But failed to report "System Running" due to a full command buffer on the SCF device.
Action
Check the state of the SCF device.

 

WARNING: FJSVscf: fan unit failure on RCI(addr = 0xXXXXXXXX), FAN#?, sub status =.0xX1,
sense info = 0xXX 0xXX 0xXX 0xXX 0xZZ 0xYY 0xNN 0x00

Meaning
Detected a fan unit failure(sub status=0x01 or 0x81) on RCI device (addr = 0xXXXXXXXX).
This message displays abnormality that this system detected, and abnormality that another device connected on the RCI network detected.
When "sub status" is 0x81 and this system is abnormal, after this message is displayed the power off of the system is executed.
When another device on RCI network is abnormal, the abnormal is notified to this system through RCI.
FAN#? represents the fan unit number.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ shows the event code.
   0x01 : Fan rotation decrease
   0x02 : Fan rotation stop
0xYY is fan number, and the number which depends on the corresponding RCI device.
0xNN is fan tray number, and the number which depends on the corresponding RCI device.
Action
When this message is displayed, it is necessary to check the abnormality of the RCI device displayed with addr.
Check the fan unit of the FAN#? , and please contact our customer engineer.

 

WARNING: FJSVscf: power supply unit failure on RCI(addr = 0xXXXXXXXX), FEP#?, sub status = 0xX2,
sense info = 0xXX 0xXX 0xXX 0xXX 0xZZ 0xYY 0xNN 0x00

Meaning
Detected a power supply unit failure(sub status=0x02 or 0x82) on RCI device (addr = 0xXXXXXXXX).
This message displays abnormality that this system detected, and abnormality that another device connected on the RCI network detected.
When "sub status" is 0x82 and this system is abnormal, after this message is displayed the power off of the system is executed.
When another device on RCI network is abnormal, the abnormal is notified to this system through RCI.
FEP#? represents the power supply unit number.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ shows the event code.
   0x00    : An abnormal power supply unit cannot be specified.
   0x01-04 : Power supply and voltage are abnormal.
   0x05    : Power supply unit which depends on device is abnormal.
0xYY is detailed information which supplements the event code (0xZZ).
00xNN is a power supply unit type or number, and it depends on the corresponding RCI device.
Action
When this message is displayed, it is necessary to check the abnormality of the RCI device displayed with addr.
Check the power supply unit of the FEP#? , and please contact our customer engineer.

 

WARNING: FJSVscf: thermal alarm on RCI(addr = 0xXXXXXXXX), SENSOR#?, sub status = 0xX6,
sense info = 0xXX 0xXX 0xXX 0xXX 0xZZ 0xYY 0x00 0x00

Meaning
Detected an abnormal temperature (sub status=0x06 or 0x86) on RCI device (addr = 0xXXXXXXXX).
This message displays abnormality that this system detected, and abnormality that another device connected on the RCI network detected.
When "sub status" is 0x86 and this system is abnormal, after this message is displayed the power off of the system is executed.
When another device on RCI network is abnormal, the abnormal is notified to this system through RCI.
SENSOR#? represents the sensor number.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ shows the event code.
   0x01 : Ambient temperature low temperature warning
   0x02 : Ambient temperature low temperature alarm
   0x03 : Ambient temperature high temperature warning
   0x04 : Ambient temperature high temperature alarm
   0x05 : Unit/Processor low temperature warning, or sensor failure
   0x06 : Unit/Processor low temperature alarm, or sensor failure
   0x07 : Unit/Processor high temperature warning
   0x08 : unit/processor high temperature alarm
0xYY is sensor number, and it depends on the corresponding RCI device.
Action
When this message is displayed, it is necessary to check the abnormality of the RCI device displayed with addr.
Check the environment where the unit is set up.
Also make sure there is nothing wrong with the inside of the RCI device.

 

WARNING: FJSVscf: node error on RCI(addr = 0xXXXXXXXX), sub status = 0x08,
sense info = 0xXX 0xXX 0xXX 0xXX 0x00 0xZZ 0xYY 0x00

Meaning
Detected a node error (sub status=0x08) on RCI device (addr = 0xXXXXXXXX).
This message displays abnormality that this system detected, and abnormality that another device connected on the RCI network detected.
When another device on RCI network is abnormal, the abnormal is notified to this system through RCI.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ shows the event code.
   0x01    : The internal failure of RCI-I/O device
   0x01-05 : SCF unit self-diagnosis error
   0x90    : RCI network is abnormal (status check time-out)
   0x91    : RCI address multiple error
   0x92    : Host node is abnormal
   0x93    : RCI device connection failure of unregistration
   0x94    : SCF degeneracy
   0xc0-ff : Hard error of RCI-I/O device
0xYY shows detailed information of RCI network abnormality (event code 0x90) or host node abnormality (event code 0x92). Or, when the inside abnormality of RCI-I/O device (event code 0x00), detailed information that depends on RCI-I/O device is shown. Other event codes are irregular values, and it does not have the meaning.
Action
When this message is displayed, it is necessary to check the abnormality of the RCI device displayed with addr.
Check RCI address is uniquely assigned to each RCI device, there are no RCI cable problems, RCI device are turned power on, unconfigured RCI devices are not connected or there are no internal failure in RCI devices. Please contact our customer engineer.

 

NOTICE: FJSVscf: I/O node status sense from RCI(addr = 0xXXXXXXXX),sub status = 0x62,
sense info = 0xXX 0xXX 0xXX 0xXX 0xZZ 0xYY 0xYY 0xYY

Meaning
Detected a sensed information of I/O node status (sub status=0x062) from RCI device (addr = 0xXXXXXXXX).
This message displays the change of the state of another device connected on the RCI network.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ shows the event code.
   0x01 : RCI-I/O device connection or power supply reentry
   0x02 : RCI-I/O device disconnect
0xYY is type or number of RCI-I/O device, and it depends on corresponding RCI-I/O device.
Action
It is not necessary.
When this message is frequently displayed, it is necessary to investigate the RCI device, and please contact our customer engineer.

 

WARNING: FJSVscf: mount error on RCI(addr = 0xXXXXXXXX), sub status = 0xX9,
sense info = 0xXX 0xXX 0xXX 0xXX 0xZZ 0xYY 0xYY 0x00

Meaning
Detected a mount error (sub status=0x09 or 0x89) on RCI device (addr = 0xXXXXXXXX).
This message displays abnormality that this system detected, and abnormality that another device connected on the RCI network detected.
When another device on RCI network is abnormal, the abnormal is notified to this system through RCI.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ shows the event code.
   0x01 : mount error (a lot of mounting)
   0x02 : mount error (few mounting)
   0x02 : mount position is abnormal
0xYY is detailed information which supplements the event code (0xZZ).
Action
When this message is displayed, it is necessary to check the abnormality of the RCI device displayed with addr.
Check the corresponding RCI device, and please contact our customer engineer.

 

WARNING: FJSVscf: unexpected sense from RCI(addr = 0xXXXXXXXX) was detected. sub status = 0xYY,
sense info = 0xXX 0xXX 0xXX 0xXX 0xZZ 0xZZ 0xZZ 0xZZ

Meaning
Detected an unexpected sense information from RCI device (addr = 0xXXXXXXXX).
sub status = 0xYY shows the device information command.
   0x4X : Device status notification
   0x70 : Device attribute display
   0x71 : Device status display
When sense information is notified according to the timing unexpected from another device connected with the RCI network, this message is displayed.
When another device on RCI network is abnormal, the abnormal is notified to this system through RCI.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ shows the notified sense information, and depends on the corresponding RCI device.
Action
When this message is displayed, it is necessary to check the abnormality of the RCI device displayed with addr.
Check the corresponding RCI device, and please contact our customer engineer.

 

WARNING: FJSVscf: device sense from RCI(addr = 0xXXXXXXXX), sub status = 0xYY,
sense info = 0xXX 0xXX 0xXX 0xXX 0xXZZ 0xZZ 0xZZ 0xZZ

Meaning
Detected a sensed information form RCI device(addr = 0xXXXXXXXX) that SCF driver does not support or undefined.
This message displays abnormality that this system detected, and abnormality that another device connected on the RCI network detected.
When another device on RCI network is abnormal, the abnormal is notified to this system through RCI.
0xYY shows the event code notified the SCF driver.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ shows notified sense information, and is an irregular value.
Action
When this message is displayed, it is necessary to check the abnormality of the RCI device displayed with addr.
Check the corresponding RCI device, and please contact our customer engineer.
When RCI device is this system, check whether to operate about "Machine Administration".

 

WARNING: FJSVscf: AC power down was detected on RCI(addr = 0xXXXXXXXX), sub status = 0xX7,
sense info = 0xXX 0xXX 0xXX 0xXX 0xZZ 0xYY 0xYY 0xYY

Meaning
Detected a AC power down (sub status=0x07 or 0x87) on RCI device. (addr = 0xXXXXXXXX)
This message displays abnormality that another device connected on the RCI network detected.
When another device on RCI network is abnormal, the abnormal is notified to this system through RCI.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ shows the event code.
    0x01 : Power failure occurred
0xZZ shows the notified sense information, and depends on the corresponding RCI device.
Action
When this message is displayed, it is necessary to check the abnormality of the RCI device displayed with addr.
Check the corresponding RCI device, and please contact our customer engineer.

 

WARNING: FJSVscf: power supply unit failure on RCI(addr = 0xXXXXXXXX), BE#?, sub status = 0xX2,
sense info = 0xXX 0xXX 0xXX 0xXX 0xZZ 0xYY 0xNN 0x00

Meaning
Detected a BE power supply unit failure(sub status=0x02 or 0x82) on RCI device (addr = 0xXXXXXXXX).
This message displays abnormality that this system detected, and abnormality that another device connected on the RCI network detected.
When "sub status" is 0x82 and this system is abnormal, after this message is displayed the power off of the system is executed.
When another device on RCI network is abnormal, the abnormal is notified to this system through RCI.
BE#? represents the BE power supply unit number.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ shows the event code.
   0x05 : BE power supply unit which depends on device is abnormal.
0xYY is detailed information which supplements the event code (0xZZ).
0xNN is a BE power supply unit type or number, and it depends on the corresponding RCI device.
Action
When this message is displayed, it is necessary to check the abnormality of the RCI device displayed with addr.
Check the power supply unit of the BE#? , and please contact our customer engineer.

 

WARNING: FJSVscf: power supply unit failure on RCI(addr = 0xXXXXXXXX),
sense info = 0xXX 0xXX 0xXX 0xXX 0xZZ 0xZZ 0xZZ 0xZZ

Meaning
Detected a power supply unit except FEP and BE failure on RCI device (addr = 0xXXXXXXXX).
This message displays abnormality that another device connected on the RCI network detected.
When another device on RCI network is abnormal, the abnormal is notified to this system through RCI.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ shows the notified sense information, and depends on the corresponding RCI device.
Action
When this message is displayed, it is necessary to check the abnormality of the RCI device displayed with addr.
Check the power supply unit of the RCI device, and please contact our customer engineer.

 

WARNING: FJSVscf: I2C error detected, error code=0xZZ, bus#=0xYY, slave address=0xNN
sense info = 0xXX 0xXX 0xXX 0xXX 0xZZ 0xYY 0xNN 0x00

Meaning
Detected I2C error.
This message displays abnormality that this system detected.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ(error code=0xZZ) is an event code. This code is a code to identify the I2C error status and the phase.
   0x0X : I2C write access error
   0x1X : I2C read access error
0xYY(bus=0xYY) shows the bus number where the I2C error occurs.
0xNN(slave address=0xNN) shows the I2C slave address.
Action
Check the state of the SCF device, and please contact our customer engineer.