4.1.2 For GP7000F models 200/200R/400/400A/400R/600/600R and PRIMEPOWER 200/400/600
WARNING: FJSVscf: _init: ddi_soft_state_init failed.
- Meaning
- Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_soft_state_init(9F).
- Action
- Allocate memory since there might not be enough kernel resources.
WARNING: FJSVscf: _init: mod_install failed.
- Meaning
- Failed to incorporate the SCF driver into the system due to the abnormal termination of mod_install(9F) (incorporates the driver into the system).
- Action
- Allocate memory since there might not be enough kernel resources.
WARNING: FJSVscf: scf_probe: ddi_soft_state_zalloc failed.
- Meaning
- Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_soft_state_zalloc(9F) (allocates an area for the driver).
- Action
- Allocate memory since there might not be enough kernel resources.
WARNING: FJSVscf: scf_probe: ddi_get_soft_state failed.
- Meaning
- Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_get_soft_state(9F) (gets an area for the driver).
- Action
- Allocate memory since there might not be enough kernel resources.
WARNING: FJSVscf: scf_probe: ddi_dev_nregs failed.
- Meaning
- The register information in the SCF device is incorrect.
- Action
- Check the state of the SCF device.
WARNING: FJSVscf: scf_attach: ddi_get_soft_state failed.
- Meaning
- Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_get_soft_state(9F)(gets an area for the driver).
- Action
- Allocate memory since there might not be enough kernel resources.
WARNING: FJSVscf: scf_attach: ddi_soft_state_zalloc failed.
- Meaning
- Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_soft_state_zalloc(9F) (allocates an area for the driver).
- Action
- Allocate memory since there might not be enough kernel resources.
WARNING: FJSVscf: scf_attach: ddi_get_soft_iblock_cookie failed.
- Meaning
- Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_get_soft_iblock_cookie(9F) (allocates resources for interrupt processing).
- Action
- Allocate memory since there might not be enough kernel resources.
WARNING: FJSVscf: scf_attach: ddi_create_minor_node failed.
- Meaning
- Failed to incorporate the SCF driver into the system because the creation of the device minor node failed.
- Action
- Make sure there is enough room in the /device file system.
WARNING: FJSVscf: scf_attach: ddi_add_intr failed.
- Meaning
- Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_add_intr(9F) (registers interrupt functions).
- Action
- Allocate memory since there might not be enough kernel resources.
WARNING: FJSVscf: scf_map_regs: ddi_regs_map_setup failed.
- Meaning
- Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_regs_map_setup(9F) (maps register).
- Action
- Allocate memory since there might not be enough kernel resources.
WARNING: FJSVscf: scf_map_regs: ddi_dev_regsize failed.
- Meaning
- Failed to incorporate the SCF driver into the system due to the abnormal termination of ddi_dev_regsize(9F) (gets the register size).
- Action
- Check the state of the SCF device.
WARNING: FJSVscf: scf_chpoll: ddi_get_soft_state failed
- Meaning
- poll(2) terminated abnormally due to the abnormal termination of ddi_get_soft_state(9F) (gets an area for the driver).
- Action
- Allocate memory since there might not be enough kernel resources.
WARNING: FJSVscf: scf_detach: ddi_get_soft_state failed
- Meaning
- Could not detach the SCF driver due to the abnormal termination of ddi_get_soft_state(9F) (gets an area for the driver).
- Action
- Allocate memory since there might not be enough kernel resources.
WARNING: FJSVscf: scf_open: ddi_get_soft_state failed
- Meaning
- Could not open the SCF driver due to the abnormal termination of ddi_get_soft_state(9F) (gets an area for the driver).
- Action
- Allocate memory since there might not be enough kernel resources.
WARNING: FJSVscf: scf_close: ddi_get_soft_state failed
- Meaning
- Could not close the SCF driver due to the abnormal termination of ddi_get_soft_state(9F) (gets an area for the driver).
- Action
- Allocate memory since there might not be enough kernel resources.
WARNING: FJSVscf: scf_read: ddi_get_soft_state failed
- Meaning
- Could not read the SCF driver due to the abnormal termination of ddi_get_soft_state(9F) (gets an area for the driver).
- Action
- Allocate memory since there might not be enough kernel resources.
WARNING: FJSVscf: scf_ioctl: ddi_get_soft_state failed
- Meaning
- SCF driver ioctl failed due to the abnormal termination of ddi_get_soft_state(9F) (gets an area for the driver).
- Action
- Allocate memory since there might not be enough kernel resources.
WARNING: FJSVscf: scf_rfantest: redundant fan test failed.
- Meaning
- Failed to start the redundant fan test that is performed periodically within the SCF driver.
- Action
- Check the state of the SCF device.
NOTICE: FJSVscf: cannot set watchdog. SCF busy.
- Meaning
- Failed to issue the CPU monitoring command to the SCF device.
- Action
- Check the state of the SCF device.
FJSVscf: ignoring debug enter sequence
- Meaning
- STOP-A was entered while the MODE switch on the operator panel was set to SECURE.
FJSVscf: allowing debug enter
- Meaning
- STOP-A was entered.
WARNING: FJSVscf: SCF went to offline mode and was restarted
- Meaning
- SCF entered the OFFLINE state and was reset.
- Action
- Check the state of the SCF device.
NOTICE: FJSVscf: scf_reset: kmem_alloc failed. cannot dump firm area
- Meaning
- Failed to allocate memory and get a dump from the SCF device firmware area when the SCF device was reset.
- Action
- Allocate memory since there might not be enough kernel resources.
NOTICE: FJSVscf: SCF online
- Meaning
- Resetting of the SCF device completed, and the device entered the ONLINE state.
WARNING: FJSVscf: scf_intr: Unexpected POFF interrupt occurred
- Meaning
- A POWER switch interrupt occurred while the toggle switch on the operator panel was set to SECURE.
NOTICE: FJSVscf: AC power down (PFAIL)
- Meaning
- A cutoff in power supply was detected.
WARNING: FJSVscf: scf_intr: Unexpected EXTOD interrupt occurred
- Meaning
- Detected an EXTOD interrupt.
- Action
- Check the state of the SCF device.
WARNING: FJSVscf: fan unit failure, FAN#?
- Meaning
- Detected a fan unit failure. FAN#? represents the fan unit number.
- Action
- Check the fan that had its number displayed.
WARNING: FJSVscf: power supply unit failure, FEP#?
- Meaning
- Detected a power supply unit failure. FEP#? represents the power supply unit number.
- Action
- Check the power supply unit that had its number displayed.
WARNING: FJSVscf: thermal alarm (X), SENSOR#?
- Meaning
- Detected an abnormal temperature.
X is a number representing the cause.
1 : Ambient temperature low temperature warning
2 : Ambient temperature low temperature alarm
3 : Ambient temperature high temperature warning
4 : Ambient temperature high temperature alarm
5 : Unit/Processor low temperature warning, or sensor failure
6 : Unit/Processor low temperature alarm, or sensor failure
7 : Unit/Processor high temperature warning
8 : unit/processor high temperature alarm
#? represents the sensor ID.
- Action
- Check the environment where the unit is set up. Also make sure there is nothing wrong with the inside of the unit.
WARNING: FJSVscf: AC power down was detected. UPS is activated.
- Meaning
- Power is now being supplied by the UPS due to a power down.
FJSVscf: AC power recovered
- Meaning
- Power was restored.
WARNING: FJSVscf: UPS low battery, UPS#?
- Meaning
- Power from the UPS has run out. UPS#? represents the UPS number.
- Action
- Charge the UPS battery.
WARNING: FJSVscf: UPS failure, UPS#?
- Meaning
- Detected a UPS failure (either a UPS hardware failure, UPS failure, or UPS circuit protector failure). UPS#? represents the UPS number.
- Action
- Check to make sure that nothing is wrong with the UPS.
WARNING: FJSVscf: SCF battery alarm, BATTERY#?
- Meaning
- Problem detected in the battery backing up SCF SRAM. #? represents the battery number.
- Action
- Check the battery.
NOTICE: FJSVscf: caught cpu watchdog alarm
- Meaning
- A CPU monitoring timeout occurred during CPU monitoring.
- Action
- Allocate memory since there might not be enough kernel resources.
NOTICE: FJSVscf: device sense Sub Code = 0x? is not support
- Meaning
- The SCF device reported sensor information that is not supported by the driver. 0x? represents the sub code of the sensor information that was reported.
- Action
- Check the state of the SCF device.
WARNING: FJSVscf: scf cmd (0x?) incomplete
- Meaning
- The SCF device could not complete a command within the prescribed time. 0x? represents the command code that could not be completed.
- Action
- Check the state of the SCF device.
WARNING: FJSVscf: scf cmd (0x?) failed. SCF hard error
- Meaning
- The command could not complete successfully on the SCF device due to a hardware error. 0x? represents the command code that ended in an error.
- Action
- Check the state of the SCF device.
WARNING: FJSVscf: scf cmd (0x?) failed. SCF RCI error
- Meaning
- The command could not complete successfully on the SCF device due to an RCI error. 0x? represents the command code that ended in an error.
- Action
- Check the state of the SCF device.
WARNING: FJSVscf: scf cmd (0x?) failed by unknown error (yy)
- Meaning
- The command could not complete successfully on the SCF device due to an undefined error. 0x? represents the command code that ended in an error and yy is the error code on the SCF device.
- Action
- Check the state of the SCF device.
WARNING: FJSVscf: SCF hardware error was detected (error status register value)
- Meaning
- SCF hardware error occurred.
- Action
- If this message was issued repeatedly, check the SCF device.
FJSVscf: kstat_create failed
- Meaning
- kstat_create failed.
- Action
- Allocate memory since there might not be enough kernel resources.
FJSVscf: switch status is unknown
- Meaning
- There is a problem with the panel switch setting.
- Action
- Check the state of the SCF device.
FJSVscf: kstat memory allocation error
- Meaning
- There is not enough memory.
- Action
- Allocate more memory.
WARNING: FJSVscf: no devise sense (interrupt status-1 register xx)
- Meaning
- An interruption that should have sensed information was detected, but no sensed information was got. xx represents the value in the interrupt status-1 register.
- Action
- Check the state of the SCF device.
WARNING: FJSVscf: Unexpected interrupt (interrupt status-1 register xx)
- Meaning
- An undefined interruption was detected. xx represents the value in the interrupt status-1 register.
- Action
- Check the state of the SCF device.
WARNING: FJSVscf: SCF HALT was detected. (halt status register xx)
- Meaning
- SCFHALT was detected. xx represents the value in the halt status register.
- Action
- Check the state of the SCF device.
WARNING: FJSVscf: scf cmd (0x?) failed. SCF buffer full, (yy) times repeated
- Meaning
- Sending a command to SCF device was repeated (yy) times due to a full command buffer on the SCF device. But they were not processed normally. 0x? represents the command code that ended in an error.
- Action
- Check the state of SCF device.
WARNING: FJSVscf: scf_map_regs: ddi_dev_regsize failed. (Ebus T.O. register)
- Meaning
- ddi_dev_regsize(9F) (gets register size) terminated abnormally.
- Action
- Check to make sure that nothing is wrong with the hardware(Ebus).
WARNING: FJSVscf: scf_map_regs: ddi_regs_map_setup failed. (Ebus T.O. register)
- Meaning
- ddi_regs_map_setup(9F) (maps register) terminated abnormally.
- Action
- Allocate memory since there might not be enough kernel resources.
WARNING: FJSVscf: scf_icotl: Status Check Timeout Control command timeout
- Meaning
- The Status Check Timeout Control command of the SCF could not complete within the prescribed time.
- Action
- Check the state of the SCF device.
WARNING: FJSVscf: EBus TimeOut. EBus T.O. Status register = 0x?.
- Meaning
- A Ebus timeout occurred. ? represents the value in the Ebus Timeout Status register.
- Action
- Check to make sure that nothing is wrong with the hardware(Ebus).
WARNING: FJSVscf: scf_intr: cannot get p-off factor.
- Meaning
- Could not get the power on/off factor from the SCF.
- Action
- Check the state of the SCF device.
panic[cpuX]/thread=0xXXXXXXXX: FJSVscf: panic request from RCI 0xXXXXXXXX
- Meaning
- The RCI device that has RCI address of ? requested the system panic.
- Action
- This message shows the state.
However, at the cluster environment etc. , another node (RCI address 0xXXXXXXXX) which detected abnormality issues the panic instruction to this node via RCI. And, when OS panic is executed, this node outputs this message.
Please investigate this node from information on another node (RCI address 0xXXXXXXXX).
WARNING: FJSVscf: cannot report PANIC.
- Meaning
- Could not notify the system panic on the other HOST when it occurred.
panic[cpuX]/thread=0xXXXXXXXX: FJSVscf: memory dumping due to pressing REQUEST switch.
- Meaning
- Started saving memory dump due to the press of REQUEST switch
NOTICE: FJSVscf: pressed REQUEST switch in auto mode, no memory dumping.
- Meaning
- REQUEST switch was pressed, but as the MODE switch is in AUTO position, memory dump was not saved.
WARNING: FJSVscf: cannot send command due to SCF busy.
- Meaning
- Failed to send commands due to busy status of the SCF device
- Action
- Check the state of the SCF device.
WARNING: FJSVscf: SCF error. System Status Register = XX unknown status.
- Meaning
- The value of System Status Register was undefined value(XX).
- Action
- Check the state of the SCF device.
WARNING: FJSVscf: power supply unit failure, BE#?
- Meaning
- Detected a BE power supply unit failure. BE#? represents the power supply unit number.
- Action
- Check the power supply unit that had its number displayed.
WARNING: FJSVscf: SCF went to offline mode again.
- Meaning
- SCF entered the ONLINE state after resetting the SCF device, but SCF entered the OFFLINE state again before reporting "System Running."
- Action
- Check the state of the SCF device.
WARNING: FJSVscf: SCF did not become online.
- Meaning
- SCF did not enter the ONLINE state after resetting the SCF device.
- Action
- Check the state of the SCF device.
WARNING: FJSVscf: scf_report_from_intr: failed to report System Running.
- Meaning
- SCF entered the ONLINE state after resetting the SCF device. But failed to report "System Running" due to a full command buffer on the SCF device.
- Action
- Check the state of the SCF device.
WARNING: FJSVscf: fan unit failure on RCI(addr = 0xXXXXXXXX), FAN#?, sub status =.0xX1,
sense info = 0xXX 0xXX 0xXX 0xXX 0xZZ 0xYY 0xNN 0x00
- Meaning
- Detected a fan unit failure(sub status=0x01 or 0x81) on RCI device (addr = 0xXXXXXXXX).
This message displays abnormality that this system detected, and abnormality that another device connected on the RCI network detected.
When "sub status" is 0x81 and this system is abnormal, after this message is displayed the power off of the system is executed.
When another device on RCI network is abnormal, the abnormal is notified to this system through RCI.
FAN#? represents the fan unit number.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ shows the event code.
0x01 : Fan rotation decrease
0x02 : Fan rotation stop
0xYY is fan number, and the number which depends on the corresponding RCI device.
0xNN is fan tray number, and the number which depends on the corresponding RCI device.
- Action
- When this message is displayed, it is necessary to check the abnormality of the RCI device displayed with addr.
Check the fan unit of the FAN#? , and please contact our customer engineer.
WARNING: FJSVscf: power supply unit failure on RCI(addr = 0xXXXXXXXX), FEP#?, sub status = 0xX2,
sense info = 0xXX 0xXX 0xXX 0xXX 0xZZ 0xYY 0xNN 0x00
- Meaning
- Detected a power supply unit failure(sub status=0x02 or 0x82) on RCI device (addr = 0xXXXXXXXX).
This message displays abnormality that this system detected, and abnormality that another device connected on the RCI network detected.
When "sub status" is 0x82 and this system is abnormal, after this message is displayed the power off of the system is executed.
When another device on RCI network is abnormal, the abnormal is notified to this system through RCI.
FEP#? represents the power supply unit number.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ shows the event code.
0x00 : An abnormal power supply unit cannot be specified.
0x01-04 : Power supply and voltage are abnormal.
0x05 : Power supply unit which depends on device is abnormal.
0xYY is detailed information which supplements the event code (0xZZ).
00xNN is a power supply unit type or number, and it depends on the corresponding RCI device.
- Action
- When this message is displayed, it is necessary to check the abnormality of the RCI device displayed with addr.
Check the power supply unit of the FEP#? , and please contact our customer engineer.
WARNING: FJSVscf: thermal alarm on RCI(addr = 0xXXXXXXXX), SENSOR#?, sub status = 0xX6,
sense info = 0xXX 0xXX 0xXX 0xXX 0xZZ 0xYY 0x00 0x00
- Meaning
- Detected an abnormal temperature (sub status=0x06 or 0x86) on RCI device (addr = 0xXXXXXXXX).
This message displays abnormality that this system detected, and abnormality that another device connected on the RCI network detected.
When "sub status" is 0x86 and this system is abnormal, after this message is displayed the power off of the system is executed.
When another device on RCI network is abnormal, the abnormal is notified to this system through RCI.
SENSOR#? represents the sensor number.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ shows the event code.
0x01 : Ambient temperature low temperature warning
0x02 : Ambient temperature low temperature alarm
0x03 : Ambient temperature high temperature warning
0x04 : Ambient temperature high temperature alarm
0x05 : Unit/Processor low temperature warning, or sensor failure
0x06 : Unit/Processor low temperature alarm, or sensor failure
0x07 : Unit/Processor high temperature warning
0x08 : unit/processor high temperature alarm
0xYY is sensor number, and it depends on the corresponding RCI device.
- Action
- When this message is displayed, it is necessary to check the abnormality of the RCI device displayed with addr.
Check the environment where the unit is set up.
Also make sure there is nothing wrong with the inside of the RCI device.
WARNING: FJSVscf: node error on RCI(addr = 0xXXXXXXXX), sub status = 0x08,
sense info = 0xXX 0xXX 0xXX 0xXX 0x00 0xZZ 0xYY 0x00
- Meaning
- Detected a node error (sub status=0x08) on RCI device (addr = 0xXXXXXXXX).
This message displays abnormality that this system detected, and abnormality that another device connected on the RCI network detected.
When another device on RCI network is abnormal, the abnormal is notified to this system through RCI.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ shows the event code.
0x01 : The internal failure of RCI-I/O device
0x01-05 : SCF unit self-diagnosis error
0x90 : RCI network is abnormal (status check time-out)
0x91 : RCI address multiple error
0x92 : Host node is abnormal
0x93 : RCI device connection failure of unregistration
0x94 : SCF degeneracy
0xc0-ff : Hard error of RCI-I/O device
0xYY shows detailed information of RCI network abnormality (event code 0x90) or host node abnormality (event code 0x92). Or, when the inside abnormality of RCI-I/O device (event code 0x00), detailed information that depends on RCI-I/O device is shown. Other event codes are irregular values, and it does not have the meaning.
- Action
- When this message is displayed, it is necessary to check the abnormality of the RCI device displayed with addr.
Check RCI address is uniquely assigned to each RCI device, there are no RCI cable problems, RCI device are turned power on, unconfigured RCI devices are not connected or there are no internal failure in RCI devices. Please contact our customer engineer.
NOTICE: FJSVscf: I/O node status sense from RCI(addr = 0xXXXXXXXX),sub status = 0x62,
sense info = 0xXX 0xXX 0xXX 0xXX 0xZZ 0xYY 0xYY 0xYY
- Meaning
- Detected a sensed information of I/O node status (sub status=0x062) from RCI device (addr = 0xXXXXXXXX).
This message displays the change of the state of another device connected on the RCI network.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ shows the event code.
0x01 : RCI-I/O device connection or power supply reentry
0x02 : RCI-I/O device disconnect
0xYY is type or number of RCI-I/O device, and it depends on corresponding RCI-I/O device.
- Action
- It is not necessary.
When this message is frequently displayed, it is necessary to investigate the RCI device, and please contact our customer engineer.
WARNING: FJSVscf: mount error on RCI(addr = 0xXXXXXXXX), sub status = 0xX9,
sense info = 0xXX 0xXX 0xXX 0xXX 0xZZ 0xYY 0xYY 0x00
- Meaning
- Detected a mount error (sub status=0x09 or 0x89) on RCI device (addr = 0xXXXXXXXX).
This message displays abnormality that this system detected, and abnormality that another device connected on the RCI network detected.
When another device on RCI network is abnormal, the abnormal is notified to this system through RCI.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ shows the event code.
0x01 : mount error (a lot of mounting)
0x02 : mount error (few mounting)
0x02 : mount position is abnormal
0xYY is detailed information which supplements the event code (0xZZ).
- Action
- When this message is displayed, it is necessary to check the abnormality of the RCI device displayed with addr.
Check the corresponding RCI device, and please contact our customer engineer.
WARNING: FJSVscf: unexpected sense from RCI(addr = 0xXXXXXXXX) was detected. sub status = 0xYY,
sense info = 0xXX 0xXX 0xXX 0xXX 0xZZ 0xZZ 0xZZ 0xZZ
- Meaning
- Detected an unexpected sense information from RCI device (addr = 0xXXXXXXXX).
sub status = 0xYY shows the device information command.
0x4X : Device status notification
0x70 : Device attribute display
0x71 : Device status display
When sense information is notified according to the timing unexpected from another device connected with the RCI network, this message is displayed.
When another device on RCI network is abnormal, the abnormal is notified to this system through RCI.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ shows the notified sense information, and depends on the corresponding RCI device.
- Action
- When this message is displayed, it is necessary to check the abnormality of the RCI device displayed with addr.
Check the corresponding RCI device, and please contact our customer engineer.
WARNING: FJSVscf: device sense from RCI(addr = 0xXXXXXXXX), sub status = 0xYY,
sense info = 0xXX 0xXX 0xXX 0xXX 0xXZZ 0xZZ 0xZZ 0xZZ
- Meaning
- Detected a sensed information form RCI device(addr = 0xXXXXXXXX) that SCF driver does not support or undefined.
This message displays abnormality that this system detected, and abnormality that another device connected on the RCI network detected.
When another device on RCI network is abnormal, the abnormal is notified to this system through RCI.
0xYY shows the event code notified the SCF driver.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ shows notified sense information, and is an irregular value.
- Action
- When this message is displayed, it is necessary to check the abnormality of the RCI device displayed with addr.
Check the corresponding RCI device, and please contact our customer engineer.
When RCI device is this system, check whether to operate about "Machine Administration".
WARNING: FJSVscf: AC power down was detected on RCI(addr = 0xXXXXXXXX), sub status = 0xX7,
sense info = 0xXX 0xXX 0xXX 0xXX 0xZZ 0xYY 0xYY 0xYY
- Meaning
- Detected a AC power down (sub status=0x07 or 0x87) on RCI device. (addr = 0xXXXXXXXX)
This message displays abnormality that another device connected on the RCI network detected.
When another device on RCI network is abnormal, the abnormal is notified to this system through RCI.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ shows the event code.
0x01 : Power failure occurred
0xZZ shows the notified sense information, and depends on the corresponding RCI device.
- Action
- When this message is displayed, it is necessary to check the abnormality of the RCI device displayed with addr.
Check the corresponding RCI device, and please contact our customer engineer.
WARNING: FJSVscf: power supply unit failure on RCI(addr = 0xXXXXXXXX), BE#?, sub status = 0xX2,
sense info = 0xXX 0xXX 0xXX 0xXX 0xZZ 0xYY 0xNN 0x00
- Meaning
- Detected a BE power supply unit failure(sub status=0x02 or 0x82) on RCI device (addr = 0xXXXXXXXX).
This message displays abnormality that this system detected, and abnormality that another device connected on the RCI network detected.
When "sub status" is 0x82 and this system is abnormal, after this message is displayed the power off of the system is executed.
When another device on RCI network is abnormal, the abnormal is notified to this system through RCI.
BE#? represents the BE power supply unit number.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ shows the event code.
0x05 : BE power supply unit which depends on device is abnormal.
0xYY is detailed information which supplements the event code (0xZZ).
0xNN is a BE power supply unit type or number, and it depends on the corresponding RCI device.
- Action
- When this message is displayed, it is necessary to check the abnormality of the RCI device displayed with addr.
Check the power supply unit of the BE#? , and please contact our customer engineer.
WARNING: FJSVscf: power supply unit failure on RCI(addr = 0xXXXXXXXX),
sense info = 0xXX 0xXX 0xXX 0xXX 0xZZ 0xZZ 0xZZ 0xZZ
- Meaning
- Detected a power supply unit except FEP and BE failure on RCI device (addr = 0xXXXXXXXX).
This message displays abnormality that another device connected on the RCI network detected.
When another device on RCI network is abnormal, the abnormal is notified to this system through RCI.
- Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ shows the notified sense information, and depends on the corresponding RCI device.
- Action
- When this message is displayed, it is necessary to check the abnormality of the RCI device displayed with addr.
Check the power supply unit of the RCI device, and please contact our customer engineer.
WARNING: FJSVscf: I2C error detected, error code=0xZZ, bus#=0xYY, slave address=0xNN
sense info = 0xXX 0xXX 0xXX 0xXX 0xZZ 0xYY 0xNN 0x00
- Meaning
- Detected I2C error.
This message displays abnormality that this system detected.
Sense info shows the following meanings.
Four bytes of 0xXX show the address of the RCI device, and are the same as "addr = 0xXXXXXXXX".
0xZZ(error code=0xZZ) is an event code. This code is a code to identify the I2C error status and the phase.
0x0X : I2C write access error
0x1X : I2C read access error
0xYY(bus=0xYY) shows the bus number where the I2C error occurs.
0xNN(slave address=0xNN) shows the I2C slave address.
- Action
- Check the state of the SCF device, and please contact our customer engineer.