Enhanced Support Facility 2.6 User's Guide |
Contents
Index
![]() ![]() |
Part 1 SCF Driver Features | > Chapter 3 Command Reference |
hsadm - Supports hot-swapping of internal power units and fans
/opt/FJSVhwr/sbin/hsadm action unit
FJSVscu, FJSVlscu
hsadm supports the hot-swapping of internal power units and fans.
This command displays the state of power supplies and fans and starts/stops the monitoring feature for both of those devices.
The command line must contain one action and at least one unit.
You can specify display, enable, or disable for action.
You can specify power and/or fan for unit.
The following models can use this command.
action
Displays the status of the specified unit. The following shows the display format:Power unit: Monitoring Mode: On / Off FEP#0 State: Okay / Needs maintenance Fan unit: Monitoring Mode: On / Off FAN#0 State: Okay / Needs maintenance
Stops the monitoring feature for all specified units.
Restarts the monitoring feature for all specified units.
This command returns the following values:
While hot-swapping a power supply, hsadm(1M) command does not display the state of the power supply which is removed.
After hot-swapping power supplies, use hsadm(1M) command to confirm that all of the power supplies which are installed are in state Okay.
Note that only the super user can execute this command.
Contents
Index
![]() ![]() |