Part 1 SCF Driver Features | > Chapter 1 Main Cabinet | > 1.2 System Operation | > 1.2.3 Using Panel Controls |
When PRIMEPOWER 1 is used, this section need not be referred.
Refer to "Table 1. 1 Mode switch of each models" for the MODE Switch displayed in each model.
Models |
MODE switch |
||
GP7000F model |
MANUAL |
AUTO |
SECURE |
PRIMEPOWER 200/400/600 |
MANUAL |
AUTO |
SECURE |
GP7000F model 1000/2000 |
MAINTENANCE |
UNLOCK |
LOCK |
PRIMEPOWER 250/450 |
MAINTENANCE *1 |
UNLOCK *1 |
LOCK *1 |
PRIMEPOWER |
MAINTENANCE |
UNLOCK |
LOCK |
Refer to "Table 1. 2 MODE switch and Function" below regarding the differences between the various operating modes.
Mode |
POWER switch |
Console |
|
Shut Down Process |
Power On |
STOP-A |
|
MANUAL or |
Yes |
Yes (Stops in OpenBoot) |
Enters OpenBoot |
AUTO |
Yes |
Yes (Solaris OS automatically starts up) |
Enters OpenBoot |
UNLOCK |
Yes |
Yes (Stops in OpenBoot) |
Enters OpenBoot |
SECURE or |
No |
No (After the power of system is turned on, Solaris OS automatically starts up) |
Ignored |
The system was designed to run with the MODE switch set to SECURE/LOCK in the majority of situations.
Setting it to SECURE/LOCK offers safer operation than AUTO/UNLOCK, as it protects against improper use of controls on the operation panel.
For example, if the MODE switch is set to AUTO, Solaris OS automatically starts up. However, when the MODE Switch is set to SECURE or LOCK, the system cannot be booted up or shutdown by pressing the POWER Switch.
When the mode switch is SECURE or LOCK, the POWER switch cannot be operated. Switch the mode as necessary.
MANUAL/MAINTENANCE/UNLOCK should only be used when performing maintenance and related work on the system. It should not be used during normal operation. Turning on the system when the MODE switch is set to MANUAL/MAINTENANCE/UNLOCK will stop it in the OBP (OpenBoot PROM) state without booting up Solaris OS.
Normally, you can enter the OpenBoot environment when STOP-A is entered on the console while Solaris OS is running. On a tty console, the Break operation is equivalent to STOP-A. It is possible to enter the OpenBoot environment only when the MODE switch is set to MANUAL, MAINTENANCE, AUTO or UNLOCK. You cannot enter the OpenBoot environment when the MODE switch is set to SECURE/LOCK.
The POWER switch only works when the MODE switch is set to MANUAL, MAINTENANCE, AUTO or UNLOCK. It will not work when the MODE switch is set to SECURE/LOCK.
You can display the current MODE switch setting with the command fjprtdiag -v.