PRIMECLUSTER Global Link Services Configuration and Administration Guide: Redundant Line Control Function 4.1 (for Linux)
Contents Index PreviousNext

Appendix A Messages and corrective actions> A.1 Messages Displayed by Redundant Line Control Function

A.1.3 Console output messages (numbers 800 to 900)

The following describes the messages output on the console by Redundant Line Control Function, explanation, and operator response.

[Message number 8xx]

Message number

Message

Meaning

Action

800

line status changed: Link Down at TRUNKING mode (interface on devicename, target=host_name)

An error occurred in the communication with the remote host system (host_name) using the physical interface (interface) controlled by the virtual interface (devicename) that is operating in the Fast switching mode.

Check whether an error has occurred on the communication path to the remote host system.

801

line status changed: Link Up at TRUNKING mode (interface on devicename, target=host_name)

The communication with the remote host system (host_name) using the physical interface (interface) controlled by the virtual interface (devicename) is recovered.

No action is required.

802

file open failed.

Failed to open the file.

Collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

803

file read failed.

Failed to read the file.

Collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

804

pipe create failed.

Failed to create the internal communication pipe.

Collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

805

internal error.

An internal error occurred.

Collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

806

cannot get my process id

Failed to obtain the local process ID.

Collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

814

cannot up interface.

Failed to up the virtual interface.

Collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

815

sha device open failed.

Failed to open the "sha" driver.

Collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

816

ioctl(SHAIOCSETRSCMON) failed.

Failed to send the monitor start request.

Collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

817

ClOpen failed.

The connection to the cluster failed.

Check that there is no mistake in the setting of a Redundant Line Control Function and a cluster system. If there is no mistake, collect materials for examination of a Redundant Line Control Function and a cluster system, and tell an error message to Fujitsu system engineer (SE). See the manual of a cluster system as to the materials necessary for examining a cluster system.

822

no data in cluster event.

No data was found in the cluster event.

Check that there is no mistake in the setting of a Redundant Line Control Function and a cluster system. If there is no mistake, collect materials for examination of a Redundant Line Control Function and a cluster system, and tell an error message to Fujitsu system engineer (SE). See the manual of a cluster system as to the materials necessary for examining a cluster system.

823

ClSetStat failed.

The cluster resource status could not be set.

Check that there is no mistake in the setting of a Redundant Line Control Function and a cluster system. If there is no mistake, collect materials for examination of a Redundant Line Control Function and a cluster system, and tell an error message to Fujitsu system engineer (SE). See the manual of a cluster system as to the materials necessary for examining a cluster system.

824

directory open failed.

Failed to open the directory.

Collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

825

signal send failed.

Failed to send the signal.

Collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

826

command can be executed only with super-user.

The execution-time authority is invalid.

Collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

827

could not allocate memory.

Failed to obtain the memory.

Collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

828

fork failed.

The fork () failed.

Collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

829

child process execute failed.

Failed to generate the child process.

Collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

830

getmsg failed.

Failed to receive the data from the "sha" driver.

Collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

831

shared library address get failed.

Failed to obtain the shared library address.

Collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

832

poll failed.

The poll () failed.

Collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

833

ioctl(SHAIOCSETIPADDR) failed.

Failed to notify the IP address.

Collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

834

interface does not exist.

The interface defined in NIC switching mode does not exist.

Please check that there is no error in the definition of a Redundant Line Control Function, and the definition of a system. Moreover, please check about the existence of the corresponding interface using the ifconfig command. When abnormalities cannot be discovered, collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

845

could not restart routed.

Failed to restart the routing daemon. The HUB monitoring function is stopped and cluster switching is performed.

Check that there is no mistake in the setting of a system, a Redundant Line Control Function, and a cluster system. If the same phenomenon occurs, collect materials for examination of a Redundant Line Control Function and a cluster system, and tell an error message to Fujitsu system engineer (SE). See the manual as to the materials necessary for examining a cluster system.

846

could not restart rdisc.

Failed to restart the router discovery daemon. The HUB monitoring function is stopped and cluster switching is performed.

Check that there is no mistake in the setting of a system, a Redundant Line Control Function, and a cluster system. If the same phenomenon occurrs, collect materials for examination of a Redundant Line Control Function and a cluster system, and tell an error message to Fujitsu system engineer (SE). See the manual as to the materials necessary for examining a cluster system.

847

internal error retry over. polling stop.

A HUB monitoring internal error occurred. The HUB monitoring is stopped.

Check that there is no mistake in the setting of a system, a Redundant Line Control Function, and a cluster system. If the same phenomenon occurrs, collect materials for examination of a Redundant Line Control Function and a cluster system, and tell an error message to Fujitsu system engineer (SE). See the manual as to the materials necessary for examining a cluster system.

848

device is inactive. polling stop.

The virtual interface for HUB monitoring is not activated. The HUB monitoring function is disabled.

Activate the virtual interface. Then, inactivate and activate the HUB monitoring function. This message may be displayed when cluster switching occurs during cluster operation, but in this case, no action is needed.

849

poll fail retry over. polling stop.

The transmission line failed as many times as specified by the retry count consecutively. The HUB monitoring function is disabled.

Check the line failure. After checking the line recovery, inactivate and activate the HUB monitoring function.

850

cannot down interface.

Failed to inactivate the physical interface.

Check that there is no mistake in the setting of a Redundant Line Control Function and a cluster system. If there is no mistake, collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

851

primary polling failed. lip=logicalIP, target=pollip.

An error of path to the primary monitoring destination was detected in the initial check of the physical interface. LogicalIP: Logical IP
Pollip: Monitoring destination IP

Check for any failure on the communication path to the monitoring destination.

852

secondary polling failed. lip=logicalIP, target=pollip.

An error of path to the secondary monitoring destination was detected in the initial check of the physical interface. LogicalIP: Logical IP, pollip: Monitoring destination IP

Check for any failure on the communication path to the monitoring destination.

853

physical interface up failed.

Failed to activate a physical interface.

Check that there is no mistake in the setting of a Redundant Line Control Function and a cluster system. If there is no mistake, collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

854

logical interface up failed.

Failed to activate a logical interface.

Check that there is no mistake in the setting of a Redundant Line Control Function and a cluster system. If there is no mistake, collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

855

cluster logical interface is not found.

The logical interface registered with the cluster was not found.

Check that there is no mistake in the setting of a system, a Redundant Line Control Function, and a cluster system. If the same phenomenon occurrs, collect materials for examination of a Redundant Line Control Function and a cluster system, and tell an error message to Fujitsu system engineer (SE). See the manual as to the materials necessary for examining a cluster system.

856

cluster configuration is incomplete.

The logical IP address cannot be activated because the cluster settings are incomplete.

Review the cluster system settings, and reboot the system

857

polling information is not defined.

Monitoring destination information is not defined.

Define monitoring destination information using the hanetpoll command.

860

interface does not exist.

There is no interface which NIC switching mode is using.

Collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

861

cannot set interface flags.

The flag operation to an interface in use became failure.

Collect materials for examination of a Redundant Line Control Function, and tell an error message to Fujitsu system engineer (SE).

870

polling status changed: Primary polling failed. (ifname,target=pollip)

Line monitoring on the primary side failed. ifname: Interface name, pollip: Monitoring destination address

Check for any failure on the communication path to the monitoring destination.

871

polling status changed: Secondary polling failed. (ifname,target=pollip)

Line monitoring on the secondary side failed. ifname: Interface name, pollip: Monitoring destination address

Check for any failure on the communication path to the monitoring destination. If monitoring stopped after checking the recovery of the communication path, make a HUB monitoring function invalid and valid using the hanetpoll command. If monitoring fails even though possible to communicate normally, tune the intervals and the number of the times of monitoring, and the time to wait for a linkup with the hanetpoll command.

872

polling status changed: PrimaryHUB to SecondaryHUB polling failed. (ifname,target=pollip)

HUB-to-HUB communication monitoring on the primary side failed. ifname: Interface name, pollip: Monitoring destination address

Check for any failure on the communication path to the monitoring destination.

873

polling status changed: SecondaryHUB to PrimaryHUB polling failed. (ifname,target=pollip)

HUB-to-HUB communication monitoring on the secondary side failed. ifname: Interface name, pollip: Monitoring destination address

Check for any failure on the communication path to the monitoring destination.

874

polling status changed: HUB repair (target=pollip)

Line failure in HUB-to-HUB communication monitoring was repaired. pollip: Monitoring destination address

No action is required.

875

standby interface failed.(ifname)

An error involving standby interface was detected in the standby patrol. ifname: Interface name

Check that there is no error in a transfer route of the standby side. When it takes long time to link up, occasionally a recovery message is output immediately after this message is output. In this case, a transfer route of the standby side is normal. Therefore, it is not necessary to deal with.

876

node status is noticed.(sourceip:status)

A node status change was notified from the remote system. sourceip: Source address, status: Notified status

Check the status of the source.

877

route error is noticed.(sourceip)

A communication path failure was notified from the remote system. sourceip: Source address

Check for any failure on the communication path to the source.

878

route error is detected.(target=IP)

A communication path failure was detected from the remote system. IP: Remote system address

Check for any failure on the communication path to the source.

880

failed to send node down notice by time out. (dstip)

Node status notification failed due to timeout. dstip: Destination address

Check for any failure of the remote system and on the communication path to the remote system.

881

semaphore is broken. (errno)

Creates a semaphore again because it is deleted.

It is not necessary to deal with.

882

shared memory is broken. (errno)

Creates a shared memory again because it is deleted.

It is not necessary to deal with.

883

activation of a wrong interface has been detected. (ifname)

Since the interface was unjustly activated by the user, the state of an interface is restored.
ifname: interface name

Check that the interface has been recovered correctly. In addition, when this message is displayed to the user operating nothing, please investigate the cause of the abnormality occurred.

884

unexpected interface deactivation has been detected. (ifname)

Since the interface was unjustly deactivated by the user, the state of an interface is restored.
ifname: interface name

Check that the interface has been recovered correctly. In addition, when this message is displayed to the user operating nothing, please investigate the cause of the abnormality occurred.

885

standby interface recovered.(ifname)

The remote system interface recovered.
ifname: Source address

It is not necessary to deal with.

886

recover from route error is noticed.(ifname)

The recovery was notified from the remote system. ifname: Interface name

It is not necessary to deal with.

887

recover from route error is detected. (target=IP)

The recovery of the remote system was detected. IP: Remote system address

It is not necessary to deal with.

888

interface is activated. (ifname)

The physical interface was activated. ifname: Interface name

It is not necessary to deal with.

889

interface is inactivated. (ifname)

The physical interface was inactivated. ifname: Interface name

It is not necessary to deal with.

890

logical IP address is activated. (logicalIP)

The logical IP address was activated. logicalIP: Logical IP

It is not necessary to deal with.

891

logical IP address is inactivated. (logicalIP)

The logical IP address was inactivated. logicalIP: Logical IP

It is not necessary to deal with.

892

logical virtual interface is activated. (ifname)

The logical virtual interface was activated. ifname: Interface name

It is not necessary to deal with.

893

logical virtual interface is inactivated. (ifname)

The logical virtual interface was inactivated. ifname: Interface name

It is not necessary to deal with.

894

virtual interface is activated. (ifname)

The virtual interface was activated. ifname: Interface name

It is not necessary to deal with.

895

virtual interface is inactivated. (ifname)

The virtual interface was inactivated. ifname: Interface name

It is not necessary to deal with.

896

path to standby interface is established. (ifname)

Monitoring by standby patrol started normally.
Ifname: A name of a standby patrol interface.

It is not necessary to deal with.

897

immediate exchange to primary interface is canceled. (ifname)

Restrained prompt failback to the primary interface by standby patrol.
ifname: A name of an interface.
This message is output when the monitor-to information to set by a hanetpoll create command is other than HUB.

It is not necessary to deal with. When executing prompt failback, use a hanetpoll modify command and change the monitor-to information to a host name or an IP address of HUB.

898

unexpected interface flags have been detected. (ifname) (code)

Since the interface was unjustly changed by the user, the state of an interface is restored.
ifname: interface name
code: detailed code

Check that the interface has been recovered correctly. In addition, when this message is displayed to the user operating nothing, please investigate the cause of the interface flag change.

899

route to polling address is inconsistent.

The network address defined to virtual interface and monitoring target is not the same, or since inappropriate routing information was registered into routing table, the mistaken monitoring is performed.

Please correct, when you check monitoring target address and there is an error. When there is no error in monitoring target address, please check whether inappropriate routing information is registered into the routing table.

[Message number 9xx]

Message number

Message

Meaning

Action

990

line status changed: all lines disabled: (devicename: interface1=Down, interface2=Down, ...)

In Fast switching mode, it is not possible to continue communicating with the other end host because all physical interfaces (interfaceN) bundled by a virtual interface in operation (devicename) became Down.

Check if or not there is any error in a transfer route of communication to the other end host for all physical interfaces.

991

line status changed: some lines in operation: (devicename: interface1=[Up|Down], interface2=[Up|Down], ...)

In Fast switching mode, part of the physical interfaces (interfaceN) bundled by a virtual interface in operation (devicename) became Down (or Up).

Check if or not there is any error in a transfer route of communication to the other end host for physical interfaces in Down status.

992

line status changed: all lines enabled: (devicename: interface1=Up, interface2=Up, ...)

In Fast switching mode, all physical interfaces (interfaceN) bundled by a virtual interface in operation (devicename) became Up and communication with the other end host recovered.

No action is required.



Contents Index PreviousNext

All Rights Reserved, Copyright (C) FUJITSU LIMITED 2005