PRIMECLUSTER Global Link Services Configuration and Administration Guide: Redundant Line Control Function 4.1 (for Linux)
|
Contents
Index

|
3.4.1 Fast switching mode
The following shows the procedure for changing configuration information for Fast switching mode:
- Inactivate the concerned virtual interface using the "stphanet" command. For information, see "7.3 stphanet Command".
- Change the configuration information.
- After changing the configuration information, activate the concerned virtual interface using the "strhanet" command. For information, see "7.2 strhanet Command".
The procedure to change the information of a monitoring function is as follows:
- Change the information of a monitoring function using a "hanetparam" command. See "7.6 hanetparam Command" for the detail. In this case, it is not necessary to reactivate a virtual interface. The information becomes valid immediately after changed.
- Reboot the system after applying changes.
The following lists the information that can be changed for Fast switching mode. No information can be changed besides the information listed below. Delete the concerned definition and add it again.
- Configuration definition information
Use the "hanetconfig" command to change the following information. For information, see "7.1 hanetconfig Command" or "7.5 hanetmask Command".
- Host name or IP address to be attached to a virtual interface or a logical virtual interface
- Interface names to be bundled by a virtual interface
- Subnet mask to a virtula interface or a logical virtual interface
- Monitoring function information
Use the "hanetparam" command to change the following information. For information, see "7.6 hanetparam Command".
- Transfer path monitoring interval
- The number of constant monitoring prior to outputting message
- The number of constant monitoring prior to switching cluster
- Timing of activating the virtual interface
- Outputting message (monitoring the physical interface)
- Switching cluster immediately after starting RMS
All Rights Reserved, Copyright (C) FUJITSU LIMITED 2005