PRIMECLUSTER Global File Services Configuration and Administration Guide 4.1 (Linux) |
Contents
Index
![]() ![]() |
Appendix A List of Messages | > A.4 GFS Shared File System Specific Management Command Messages |
special is not the GFS Shared File System's representative partition.
Specify the representative partition and re-execute the command.
The specified fsid value lies outside the valid range.
Review specified FSID and re-execute the command.
A GFS Shared File System identified by the specified fsid does not exist.
Check specified FSID is correct.
The initialization processing of communication failed due to insufficient memory or swap space.
Check the system environment whether memory or swap space insufficiency has not occurred.
The file system monitoring mechanism is not operating.
Check whether the sfcfrmd process exists using the ps command.
When it does not exist, activate the file system monitoring mechanism using the sfcfrmstart command.
Illegal data exists in the file system configuration information for the file system whose fsid is FSID.
Restore the management partition using its backup previously saved.
Obtaining the device name for the file system whose fsid is FSID failed.
Check the system environment whether it is proper.
Illegal data exists in the file system configuration information for the file system whose fsid is FSID.
Restore the management partition using its backup previously saved.
Opening /etc/mtab failed.
Check the system environment using errormsg.
The file system monitoring mechanism is not operating.
Check whether the file system monitoring mechanism is running.
Contents
Index
![]() ![]() |