Opening the partition (special) failed.
Take action according to errmsg.
Memory allocation failed.
Wait for the termination of another process or increase the swap space, and re-execute the command.
The file system monitoring mechanism is not operating.
Check whether the file system monitoring mechanism is running.
Reading the file system configuration information failed.
Collect the diagnostic data with pclsnap, and contact your local Customer Support.
The file system configuration information has reached the limit.
Collect the diagnostic data with pclsnap, and contact your local Customer Support.
The specified partition (special) is not an sfcfs file system partition.
Check whether the specified partition is an sfcfs file system partition.
An unexpected error was detected.
Collect the diagnostic data with pclsnap, and contact your local Customer Support submitting it along with text of the error message displayed.
The partition (special) is unavailable because another command is using it.
Upon termination of the other command, re-execute the command.
Reading the superblock or volume information on the partition (special) failed.
Delete the target file system where it is unnecessary. For details, see "Deleting" in this manual. When it is a necessary file system, restore it running a full scan with sfcfsck(8). For details, see "Action for I/O errors" in this manual.
Obtaining the attribute of the specified partition (special) failed.
Take action according to errmsg.
The command was executed on a node other than the nodes sharing the file system.
Execute the command on a file system sharing node.
An error was detected in volume information.
Collect the diagnostic data with pclsnap, and contact your local Customer Support.
The partition configuration data of the specified partition is invalid.
Check whether the specified partition is an sfcfs file system partition.
The specified partition (special) is invalid.
Check whether the specified partition is correct.
Obtaining the size of the device (special) failed.
Take action according to errmsg.
An error occurred in the special file (special) I/O operation.
Take action according to errmsg.
A read error occurred with the {primary | secondary} superblock.
Check the disk status.
The specified file system is not an sfcfs file system.
Check whether the specified file system is an sfcfs file system.
The command was executed on a node other than the nodes sharing the file system.
Execute this command on a file system sharing node.
special is not a block device.
Check whether the specified partition is correct.