PRIMECLUSTER Global File Services Configuration and Administration Guide 4.1 (Linux) |
Contents
Index
![]() ![]() |
Appendix A List of Messages | > A.2 GFS Shared File System Daemon messages | > A.2.2 Error messages |
This section explains the sfcfs_mount command messages that is called sfcfsd daemon.
The mounting failed due to a memory allocation failure.
Check the system status and wait for the termination of another process or increase the swap space, and re-execute the command.
The mounting failed due to an internal error.
Collect the diagnostic data with pclsnap, and contact your local Customer Support submitting it along with text of the error message displayed.
The file system monitoring mechanism is not operating.
Check whether the file system monitoring mechanism is running.
The specified partition (special) does not exist in the file system configuration information.
Check whether the specified partition is correct.
Reading the file system configuration information failed.
Collect the diagnostic data with pclsnap, and contact your local Customer Support.
The port number definition used in Ac-to-MDS communication is not found.
Review the port number definition in /etc/services.
The host name information for AC-to-MDS communication cannot be obtained.
Review the host name definition in /etc/hosts, or change the host name with sfcadm(8).
Creating a directory failed.
Take action according to errmsg.
The mounting fails because it has already been mounted.
Check whether the mounting has not been done with mount(8), and take action.
The mounting cannot be performed because recovery processing is in progress.
No particular action is required.
Access Client cannot connect to meta-data server. Therefore, mount the file system will be failed.
Check meta-data server down. In this case, try mount again.
The sfcfs module has not been loaded.
Check whether the sfcfs module has been loaded.
An unexpected error was detected on the mounting.
Check whether special and mountpoint actually exist. When it does not exist, it is possible that the specification of a directory or a file is error, or the directory of mountpoint is not created.
When an error is in specification, please specify the correct file and directory.
Please create a directory, when the directory of mountpoint is not created.
When each of the file and the directory exists, the host name of the sharing node of the relevant file system may not be a thing on the same network. Please confirm host name of the node information with the sfcinfo (8) command with -an option.
Please perform sfcfs_mount again after changing into the host name on the same network by the sfcadm (8) command with -u option, when the specification host name is wrong.
When unsolvable by the above methods, collect the diagnostic data with pclsnap, and contact your local Customer Support.
For details on sfcinfo(8),sfcadm(8), see "sfcinfo(8)","sfcadm(8)" in this manual.
The mounting succeeded, but adding the mount information to /etc/mtab failed.
Check the /etc/mtab settings and add the relevant mount information to /etc/mtab.
Deleting the mount information from /etc/mtab failed.
Check the /etc/mtab settings and delete the relevant mount information from /etc/mtab.
An unknown error was detected.
Collect the diagnostic data with pclsnap, and contact your local Customer Support.
Contents
Index
![]() ![]() |