PCI Hot Plug User's Guide I/O device edition - for Solaris (TM) Operating Environment -
Contents PreviousNext

Chapter 2 Overview of replacement and extension of PCI cards

2.2 Extension of PCI cards

This section describes outline to extend PCI cards using PCI Hot Plug feature.

About software which makes PCI card redundantly, please refer to each manual of the software.

2.2.1 Extension of PCI cards on non-redundant system 

When not using the redundant configuration software, the extension procedure of PCI cards is as follows.

Please refer to "Chapter 3 File devices" or "Chapter 4 Network devices" about detailed extending procedure of PCI cards.

File devices procedures

  1. Setup I/O devices which will be added to system

    Setup devices which will be added to system in the case of file devices on Solaris 8 OE.

  2. Stop the hardware monitoring of the Machine Administration

    Stop the hardware abnormal monitoring of the Machine Administration.

  3. Stop the daemons

    If you use the Fibre Channel Card (PW028FC3*/PW028FC4*/PW028FC5*), stop the daemons.

  4. Add PCI cards

    Extend PCI cards.

  5. Connect PCI cards

    It changes into the state where the PCI card is usable.

  6. Start the daemons

    If you use the Fibre Channel Card (PW028FC3*/PW028FC4*/PW028FC5*), start the daemons.

  7. Start the hardware monitoring of the Machine Administration

    Update the hardware configuration information, and restart the hardware abnormal monitoring of the Machine Administration.

  8. Preparation to recognize devices for Fibre Channel

    If you use SAN management function, preparation to recognize devices.

  9. Set up driver
    1. Add the driver configuration of PCI cards

      Add the driver configuration of PCI cards

    2. Add the configuration of device driver

      Add the configuration of device driver in the case of file devices.

  10. Setup applications

    Configure the high layer products and services about extended PCI cards.

  11. Start applications

    Start high layer products and services used by the replaced PCI card.

Network devices procedures

  1. Setup I/O devices which will be added to system

    Setup devices which will be added to system in the case of file devices on Solaris 8 OE.

  2. Stop the hardware monitoring of the Machine Administration

    Stop the hardware abnormal monitoring of the Machine Administration.

  3. Add PCI cards

    Extend PCI cards.

  4. Connect PCI cards

    It changes into the state where the PCI card is usable.

  5. Start the hardware monitoring of the Machine Administration

    Update the hardware configuration information, and restart the hardware abnormal monitoring of the Machine Administration.

  6. Connect equipment to PCI cards

    Connect equipment to PCI cards.

  7. Set up driver
    1. Add the driver configuration of PCI cards

      Add the driver configuration of PCI cards

    2. Add the configuration of device driver

      Add the configuration of device driver in the case of file devices.

  8. Setup applications

    Configure the high layer products and services about extended PCI cards.

  9. Start applications

    Start high layer products and services used by the replaced PCI card.

2.2.2 Extension of PCI cards with new redundant system 

The procedure of using the extended PCI card and establishing a new redundant configuration is as follows.

Please refer to "Chapter 3 File devices" or "Chapter 4 Network devices" about detailed extending procedure of PCI cards.

File devices procedures

  1. Setup I/O devices which will be added to system

    Setup devices which will be added to system in the case of file devices on Solaris 8 OE.

  2. Stop the hardware monitoring of the Machine Administration

    Stop the hardware abnormal monitoring of the Machine Administration.

  3. Stop the daemons

    If you use the Fibre Channel Card (PW028FC3*/PW028FC4*/PW028FC5*), stop the daemons.

  4. Add PCI cards

    Extend PCI cards.

  5. Connect PCI cards

    It changes into the state where the PCI card is usable.

  6. Start the daemons

    If you use the Fibre Channel Card (PW028FC3*/PW028FC4*/PW028FC5*), start the daemons.

  7. Start the hardware monitoring of the Machine Administration

    Update the hardware configuration information, and restart the hardware abnormal monitoring of the Machine Administration.

  8. Preparation to recognize devices for Fibre Channel

    If you use SAN management function, preparation to recognize devices.

  9. Setup driver
    1. Add the driver configuration of PCI cards

      Add the driver configuration of PCI cards

    2. Add the configuration of device driver

      Add the configuration of device driver in the case of file devices.

  10. Setup redundant system

    Configure the environmental configuration of a new redundant system and activate.

  11. Setup applications

    Configure the high layer products and services about a new redundant system.

  12. Start applications

    Start high layer products and services used by the new redundant system

Network devices procedures

  1. Setup I/O devices which will be added to system

    Setup devices which will be added to system in the case of file devices on Solaris 8 OE.

  2. Stop the hardware monitoring of the Machine Administration

    Stop the hardware abnormal monitoring of the Machine Administration.

  3. Add PCI cards

    Extend PCI cards.

  4. Connect PCI cards

    It changes into the state where the PCI card is usable.

  5. Start the hardware monitoring of the Machine Administration

    Update the hardware configuration information, and restart the hardware abnormal monitoring of the Machine Administration.

  6. Connect equipment to PCI cards

    Connect equipment to PCI cards.

  7. Setup driver
    1. Add the driver configuration of PCI cards

      Add the driver configuration of PCI cards

    2. Add the configuration of device driver

      Add the configuration of device driver in the case of file devices.

  8. Setup redundant system

    Configure the environmental configuration of a new redundant system and activate.

  9. Setup applications

    Configure the high layer products and services about a new redundant system.

  10. Start applications

    Start high layer products and services used by the new redundant system.

2.2.3 Extension of PCI cards to redundant system 

When extending PCI cards to the existing redundant system, it is possible to extend PCI cards without stopping services and applications. The extension procedure of PCI card to existing redundant system is as follows.

File devices procedures

  1. Setup I/O devices which will be added to system

    Setup devices which will be added to system in the case of file devices on Solaris 8 OE.

  2. Stop the hardware monitoring of the Machine Administration

    Stop the hardware abnormal monitoring of the Machine Administration.

  3. Stop the daemons

    If you use the Fibre Channel Card (PW028FC3*/PW028FC4*/PW028FC5*), stop the daemons.

  4. Add PCI cards

    Extend PCI cards.

  5. Connect PCI cards

    It changes into the state where the PCI card is usable.

  6. Start the daemons

    If you use the Fibre Channel Card (PW028FC3*/PW028FC4*/PW028FC5*), start the daemons.

  7. Start the hardware monitoring of the Machine Administration

    Update the hardware configuration information, and restart the hardware abnormal monitoring of the Machine Administration.

  8. Preparation to recognize devices for Fibre Channel

    If you use SAN management function, preparation to recognize devices.

  9. Set up driver
    1. Add the driver configuration of PCI cards

      Add the driver configuration of PCI cards

    2. Add the configuration of device driver

      Add the configuration of device driver in the case of file devices.

  10. Connect to redundant system

    Connect device paths and interfaces of the replaced PCI card to the redundant system.

    Switch the online path for extended path if needed.

Network devices procedures

  1. Setup I/O devices which will be added to system

    Setup devices which will be added to system in the case of file devices on Solaris 8 OE.

  2. Stop the hardware monitoring of the Machine Administration

    Stop the hardware abnormal monitoring of the Machine Administration.

  3. Add PCI cards

    Extend PCI cards.

  4. Connect PCI cards

    It changes into the state where the PCI card is usable.

  5. Start the hardware monitoring of the Machine Administration

    Update the hardware configuration information, and restart the hardware abnormal monitoring of the Machine Administration.

  6. Connect equipment to PCI cards

    Connect equipment to PCI cards.

  7. Set up driver
    1. Add the driver configuration of PCI cards

      Add the driver configuration of PCI cards

    2. Add the configuration of device driver

      Add the configuration of device driver in the case of file devices.

  8. Connect to redundant system

    Connect device paths and interfaces of the replaced PCI card to the redundant system.

  9. Switch the redundant path

    Switch the online path for extended path if needed.


Contents PreviousNext

All Rights Reserved, Copyright(C) FUJITSU LIMITED 2005